The AirGreen magazineNovember 2026

Central heat pumps

Long-lasting central heat pump: three 4-ton models and what their documents show

Three 4-ton central heat pumps sold by AirGreen, side by side with no ranking: LG LGRED, ELIOS and GREE UNIX R32. Heating cost over twenty winters, the parts that protect the unit, extreme cold and certified values.

By the AirGreen team9 min read
Technician testing the components of an opened heat pump outdoor unit on a deck
Comparison · Central heat pumps · 4 tons

Twenty winters on the South Shore: three 4-ton central heat pumps and what their documents show

Article published November 6, 2026 · updated November 17, 2026

A central heat pump installed this year in Longueuil, Brossard or Saint-Lambert may still be heating the house in 2046. No one can promise how long a unit will last. What can be read is what each manufacturer had certified and what it writes about the parts that work hardest in winter. This page compares three 48,000 BTU/h models sold by AirGreen, all on A2L refrigerant: LG LGRED, ELIOS and GREE UNIX R32. They are shown in alphabetical order, with no ranking.

3 models · 4 nominal tonsR-32 and R-454B3 AHRI certificates read on NEEP on November 17, 2026No ranking
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 48,000 BTU/h house, at Hydro-Québec Rate D, taxes included, with the Montréal Intl climate data used on all our comparison pages. The three heat pumps are calculated exactly the same way; only their certified efficiencies change. Their certified cooling capacities range from 46,000 to 48,000 BTU/h: the calculation uses the common nominal size, 48,000 BTU/h. Electric baseboards serve as the reference point.

How this amount is calculated
  1. Heat needed over the winter. A house whose heat loss reaches 48,000 BTU/h ( kW) at −23.1 °C, Montréal's design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for heating around the clock, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (the “Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup planned for when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 48,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above; the average price, 9.104¢, is the one Hydro-Québec's calculators use. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

Twenty winters

What heating would cost, winter after winter, through 2046

The same calculation as above, repeated winter after winter: heating around the clock, same house, same rate. Slide to choose the number of winters. The curves add up the electricity of each winter; the gap with baseboards widens accordingly.

Price per kWh

How to read this: the rate and the efficiency stay at today's values for the whole period. Hydro-Québec revises its rates every year, and the efficiency of an aging unit depends on its maintenance: these amounts compare the three models with each other; they do not predict a bill or a service life.

What protects the unit

The parts that work in winter, according to each manufacturer

Outside, the outdoor unit spends the winter between frost, thaw, snow and defrost cycles. Here is what each document describes for the compressor, the outdoor base pan, the heat exchanger and refrigerant monitoring. A “not stated” cell means the document consulted does not say; it is not proof that the feature is absent.

Swipe the table left to see all three columns.

The base pan heater

Defrost water drops into the outdoor unit's base pan. In deep cold, it can freeze there and build up. All three manufacturers declare a base pan heater to NEEP, each with its own wattage and switch-on threshold: those figures are in the table.

Leak detection

R-32 and R-454B are A2L refrigerants, mildly flammable. GREE and ELIOS describe a leak sensor in the indoor unit; the LG document consulted for this page does not mention one, which does not mean it is absent.

Extreme cold

From 8.3 to −30 °C: what is published for each one

Pick a temperature. Each card shows, in this order: a NEEP-certified point, otherwise the range between the two published values on either side of that temperature, otherwise the last published value with what the manufacturer says beyond it. Capacities are maximum heating capacities.

Reading the chart. Circles are NEEP-certified points. The coldest point is not at the same temperature for all three: −25 °C for LG, −30 °C for ELIOS and GREE. At those points, the values do not compare with each other. At 8.3, −8.3 and −15 °C, all three certificates have a point at the same place.
Maintenance

Four habits that count over twenty years

The earlier version of this article stressed maintenance. The advice stays, backed by what the documents let you check. The installed unit's manual remains the reference.

The indoor unit's filter

A clogged filter cuts airflow and makes the unit work harder. LG's data sheet for the KNSLB481A indoor unit lists a 20 × 20 × 1 in. filter; for the other two, the size is read on the installed unit and in its manual.

A clear outdoor unit

Snow, ice, leaves and fences too close block the air intake and the drainage of defrost water. Minimum clearances are in the model's installation manual; the installer follows them at installation.

The condensate drain

In cooling, the indoor unit removes water from the air. The drain and its trap must stay clear; standing water is often noticed before it overflows.

A yearly visit by a refrigeration technician

Pressures, refrigerant charge and electrical connections are checked with instruments and a licence. Error codes shown on the unit, written down with their date, help the technician diagnose.

Sound

Three outdoor units, three ways of publishing sound

dB(A)

How to read these figures. dB(A) measures a noise level as the ear perceives it: the lower the number, the quieter the unit. Each value is the one the manufacturer publishes for the outdoor unit.

Why this is not a ranking. The three documents do not all state the method or the measuring distance. Different method — not comparable.

Measurements published by each manufacturer with its own method: read them separately, not as a ranking.

Installation

Piping, dimensions and electrical protection

The limits printed in the manuals and brochures. The installer confirms them on site for the chosen combination.

Swipe the table left to see all three columns.

Frequently asked questions

What people ask about how long a central heat pump lasts

How long does a central heat pump last?

None of the three documents consulted promises a service life. The Québec magazine Protégez-Vous gives an average of 15 to 20 years for air-to-air heat pumps. Actual life depends on installation, maintenance, use and climate; this page shows what is documented, not a guaranteed lifespan.

Why these three models and not the ones in the earlier article?

The 2026 version of this article named three older models and testimonials that a data page cannot verify. This version compares three 4-ton central heat pumps sold by AirGreen today, on A2L refrigerant, with their AHRI certificates.

Why 4 tons?

48,000 nominal BTU/h, the size of a large single-family house. The right size, however, follows from the house's heat loss at −23.1 °C, Montréal's design temperature, not from floor area alone.

Does the twenty-winter cost account for rate increases?

No. The chart keeps the April 1, 2026 rate and today's certified efficiency for the whole period. It compares the three models with each other under the same conditions; a rate increase would raise every curve, baseboards included.

What does the outdoor base pan heater do?

It keeps defrost water from freezing in the pan. According to their declarations to NEEP, LG switches on a 120 W heater at 0 °C and below, ELIOS a 150 W heater below 3 °C in heating, and GREE a 160 W heater below 1 °C or during defrost.

Can the coldest points be compared?

Not directly. The LG certificate gives its coldest point at −25 °C; those of ELIOS and GREE at −30 °C. At −15 °C, all three are measured at the same place: 46,000 BTU/h for LG and ELIOS, 48,000 BTU/h for GREE, at maximum capacity.

Are they eligible for grants?

LogisVert eligibility depends on Hydro-Québec's official list in effect on the purchase date and on the installed combination. This page promises no amount; the current list is checked at the time of the quote.

Certified data

All AHRI and NEEP values

Swipe the table left to see all three columns.

higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. Capacities and COP by temperature, and the coldest point, are not highlighted.

All three are on AirGreen's website.

To choose for your house, talk it over with our team: bring the floor area, the condition of the ducts and your current heating.

Sources and documents

Where each figure comes from

NEEP, record 422330 (LG LGRED KUSXA482A)AHRI 215735574 · accessed November 17, 2026 NEEP, record 383654 (ELIOS ESH)AHRI 216046600 · accessed November 17, 2026 NEEP, record 378410 (GREE UNIX R32, E series)AHRI 217120761 · accessed November 17, 2026
LG, Engineering Manual, R32 multi-position air handling units (EM_SZ_MultiPositionAHU_LGRED_R32_03_25)p. 18: KUSXA482A / KNSLB481A, ranges, sound, dimensions, weight, compressor, piping · KSSLB481A data sheet: 20 × 20 × 1 in. filter
ELIOS, Central-Elios brochure (Elios_Central-Elios_202509_EN_V02)ESHMA48R2AN1 / EAHMA48R4AS1: ranges, sound, dimensions, weight, piping, Gold Fin coil, leak detection
GREE, UNIX R32 central system brochure (document 062025)GUD60W2/NhE-D(U) / GUD48AH2/G-D(U): ranges, sound, dimensions, weight, piping, MCA/MOP, leak sensor
Protégez-Vous, Comment choisir une thermopompe (in French)Average service life of an air-to-air heat pump Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5 · estimated operating cost NRCan, HOT2000 climate map, Montréal Intl4,167 degree-days (18 °C), −23.1 °C design
You made it to the end.Share it with someone it could help.
Keep reading

In the same blog

AirGreen Climatisation & Chauffage

From reading to your home.

An AirGreen advisor assesses your situation on site, free of charge, and gives you a quote within 24 hours.

  • RBQ licence 5645-9605-01Subclasses 15.8, 15.10 and 16
  • Free on-site estimateAn advisor assesses your needs
  • Quote within 24 hoursClear and detailed

Leave a comment