The narrowest: the 2400
The FXM4X 2400 is the narrowest cabinet: 17-5/8 in (448 mm); the 4800 and 6000, 24-11/16 in.
FXM4X Fan Coils Product Specifications, 496 41 5402 04 (July 2, 2019), dimensional dataCOMFORTMAKER // FXM4X
Which heater kit goes in which FXM4X cabinet?
The values on this page are the ones COMFORTMAKER publishes.
COMFORTMAKER // FXM4X
This fan coil’s heat is a kit you choose; the cabinet decides which ones fit.
The brand calls it the FXM4X fan coil: a cabinet that pushes air through your ductwork and holds an EHK electric heater kit, from 5 to 30 kW. Six cabinets from 2 to 5 tons, seven kits from 5 to 30 kW, four positions: the tool below sorts them out.
Page updated November 5, 2026
This page answers
Which heater kit goes in which FXM4X cabinet?
Sold and installed by AirGreen.
We install in Montreal, Laval, Longueuil, the South Shore and the North Shore.
01 // The tool
Pick the cabinet, the heater kit and the installation position. The tool tells you whether the sheet approves that kit in that cabinet, then gives its output, its supply, the cabinet dimensions and the kits the position calls for.
Cabinet
Heater kit (kW at 230 V)
Position
Values printed on the sheet: kW at 230 V and at 208 V; amps, minimum ampacity and fuse at 208 V and at 230 V. No 240 V value is published. Kits are named by their printed output. Of the seven kits in the tool, the 24 and 30 kW kits ship three-phase and convert to single phase on site. Outside the tool, the sheet approves three more kits: a 9 kW kit shipped single phase (convertible to three-phase) and a 15 kW three-phase kit from the 3600 cabinet, and an 18 kW three-phase kit from the 4200. The sheet (rev. 04) prints the wire size of every kit; the tool repeats it for the 10 kW kit. For the 4800 and 6000 cabinets, the printed millimetres do not match the inches: the tool gives the inches.
| Cabinet | 5 kW | 8 kW | 10 kW | 15 kW | 20 kW | 24 kW | 30 kW |
|---|---|---|---|---|---|---|---|
| 2400 | yes | yes | yes | yes | — | — | — |
| 3000 | yes | yes | yes | yes | yes | — | — |
| 3600 | yes | yes | yes | yes | yes | — | — |
| 4200 | yes | yes | yes | yes | yes | — | — |
| 4800 | yes | yes | yes | yes | yes | yes | yes |
| 6000 | yes | yes | yes | yes | yes | yes | yes |
Approved
10 kW kit, 3600 cabinet
The sheet approves the 10 kW kit in the 3600 cabinet; in the upflow position, no position kit is required.
FXM4X sheet (496 41 5402 04, July 2, 2019): heater applicability and electrical data, dimensional data, accessories.
The COMFORTMAKER shop
Price on quotation, after the on-site assessment.
02 // Did you know
The FXM4X 2400 is the narrowest cabinet: 17-5/8 in (448 mm); the 4800 and 6000, 24-11/16 in.
FXM4X Fan Coils Product Specifications, 496 41 5402 04 (July 2, 2019), dimensional dataIn the downflow position, three kits are needed: conversion, base and gasket.
FXM4X Fan Coils Product Specifications, 496 41 5402 04 (July 2, 2019), p. 1 and accessoriesThe cabinet insulation is 1 in (25 mm) thick, R-4.2.
FXM4X Fan Coils Product Specifications, 496 41 5402 04 (July 2, 2019), p. 1; 25 mm: AirGreen calculation03 // The comparison
The two sizes share one cabinet; what changes fits in a few lines.
| Value | FXM4X3600 | FXM4X4200 |
|---|---|---|
| Nominal capacity | 3 ton | 3.5 ton |
| Cabinet H × W × D | 49-5/8 × 21-1/8 × 22-1/16 in | 49-5/8 × 21-1/8 × 22-1/16 in |
| Shipping weight | 157 lb | 157 lb |
| Nominal airflow | 1,200 CFM | 1,400 CFM |
| ECM motor | 1/2 hp | 1/2 hp |
| Filter | 19-7/8 × 21-1/2 in | 19-7/8 × 21-1/2 in |
| Suction connection | 3/4 in | 7/8 in |
| 5 kW kit: MCA | 26.0 A at 208 V · 28.4 A at 230 V | 31.2 A at 208 V · 33.5 A at 230 V |
| 18 kW three-phase kit | Not approved | Approved |
Same cabinet, same filter, same motor horsepower: the 4200 moves 200 CFM more (AirGreen calculation) and also takes the 18 kW three-phase kit. With the 5 kW kit, the sheet gives it a higher minimum ampacity.
FXM4X Fan Coils Product Specifications, 496 41 5402 04 (July 2, 2019): dimensional data, physical data, heater table
04 // Published figures
| Value | 2400 | 3000 | 3600 | 4200 | 4800 | 6000 |
|---|---|---|---|---|---|---|
| Nominal capacity | 2 ton | 2.5 ton | 3 ton | 3.5 ton | 4 ton | 5 ton |
| H × W × D, in (as printed) | 49-5/8 × 17-5/8 × 22-1/16 | 53-7/16 × 21-1/8 × 22-1/16 | 49-5/8 × 21-1/8 × 22-1/16 | 49-5/8 × 21-1/8 × 22-1/16 | 53-1/16 × 24-11/16 × 22-1/16 | 59-3/16 × 24-11/16 × 22-1/16 |
| H × W × D, mm (as printed) | 1,261 × 448 × 560 | 1,357 × 537 × 560 | 1,261 × 537 × 560 | 1,261 × 537 × 560 | measure on site | measure on site |
| Shipping weight | 122 lb | 146 lb | 157 lb | 157 lb | 185 lb | 201 lb |
| Nominal airflow | 800 CFM | 1,000 CFM | 1,200 CFM | 1,400 CFM | 1,600 CFM | 2,000 CFM |
| ECM motor | 1/3 hp | 1/2 hp | 1/2 hp | 1/2 hp | 3/4 hp | 3/4 hp |
| Coil | slope | slope | A | A | A | A |
| Filter, in | 16-3/8 × 21-1/2 | 19-7/8 × 21-1/2 | 19-7/8 × 21-1/2 | 19-7/8 × 21-1/2 | 23-5/16 × 21-1/2 | 23-5/16 × 21-1/2 |
| Fan coil only: FLA / MCA / max fuse | 2.8 / 3.5 / 15 A | 4.1 / 5.1 / 15 A | 4.1 / 5.1 / 15 A | 4.1 / 5.1 / 15 A | 6.0 / 7.5 / 15 A | 6.0 / 7.5 / 15 A |
| Tool kits approved (kW) | 5, 8, 10, 15 | 5, 8, 10, 15, 20 | 5, 8, 10, 15, 20 | 5, 8, 10, 15, 20 | 5, 8, 10, 15, 20, 24, 30 | 5, 8, 10, 15, 20, 24, 30 |
| Downflow: conversion | EBAC01DFS | EBAC01DFS | EBAC02DFA | EBAC02DFA | EBAC02DFA | EBAC02DFA |
| Downflow: base | EBAC02NCB | EBAC03NCB | EBAC03NCB | EBAC03NCB | EBAC04NCB | EBAC04NCB |
For the 4800 and 6000 cabinets, the printed millimetres do not match the printed inches (height of the 4800, depth of both): we give the inches; measure on site before planning the space. MCA: minimum circuit ampacity; max fuse: the largest fuse or breaker allowed (printed as MOCP or max fuse depending on the document).
FXM4X Fan Coils Product Specifications, 496 41 5402 04 (July 2, 2019): dimensional data, physical data, electrical data, heater table, accessories
05 // Good to know
The sheet never says furnace: the FXM4X is a fan coil, with a coil, an ECM motor and a factory-installed thermostatic expansion valve (TXV). It leaves the factory with a “no heat” plug kit in place; the electric heat comes from the EHK kit installed on site. With a CSH6 heat pump, it becomes the indoor unit of the central system.
Upflow and horizontal left: no kit. Horizontal right: gasket EBAC01GSK. Downflow: conversion EBAC01DFS (slope coils of the 2400 and 3000) or EBAC02DFA (A coils), base EBAC02NCB, EBAC03NCB or EBAC04NCB depending on the cabinet, and gasket EBAC01GSK.
A 24 or 30 kW kit only goes in the 4800 and 6000 cabinets. The 2400 stops at 15 kW; the 20 kW kit comes in from the 3000. Supplied three-phase, the 24 and 30 kW kits convert to single phase on site, and the sheet then prints their wiring on one circuit or on three. Throughout, the sheet gives output at 230 V and 208 V only.
06 // Warranty
The sheet refers to the warranty certificate for complete details and restrictions, including coverage for other applications.
FXM4X Fan Coils Product Specifications, 496 41 5402 04 (July 2, 2019), p. 1
AirGreen // COMFORTMAKER
07 // Questions
In the brand’s documents, it is a fan coil: the FXM4X. The cabinet moves the air; the electric heat comes from the EHK kit installed in it. We keep the word “furnace” in the title because that is what people search for.
The sheet approves the 5, 8, 10 and 15 kW kits in the 2400; it adds the 20 kW kit from the 3000, then the 24 and 30 kW kits in the 4800 and 6000. The output your home needs is measured during the on-site assessment, not read off a table.
It depends on the kit and the voltage. Take the 15 kW kit on a single circuit (EHK15AKF): minimum ampacity of 76.3 A at 208 V and 83.4 A at 230 V, maximum fuse or breaker of 80 A at 208 V and 90 A at 230 V. The same kit can also be wired on two circuits. The printed minimum ampacity includes the motor of the largest fan coil used with the kit; your supply is confirmed during the on-site assessment.
A washable filter is factory supplied. Its size depends on the cabinet: 16-3/8 × 21-1/2 in for the 2400, 19-7/8 × 21-1/2 in for the 3000, 3600 and 4200, 23-5/16 × 21-1/2 in for the 4800 and 6000.
The cabinet has two drain fittings, primary and secondary, 3/4 in, with brass inserts.
Yes: the CSH6 sheet publishes its tested combinations with the FXM4X24, FXM4X36, FXM4X48 and FXM4X60. The heat of each combination, with its kit, is worked out in the tool on the central heat pumps page.
The sheet publishes a 5-year No Hassle Replacement limited warranty, a 5-year parts limited warranty and an additional 5 years on parts with timely registration, for owner occupied, residential applications only. COMFORTMAKER does not cover labour.
AirGreen calculations (kW conversions, sums, percentage shares) are made on the published values and labelled as such.
AirGreen // Air conditioning and heating
We look at the space for the cabinet, the ductwork and the panel, then propose the cabinet and the heater kit.
Page updated November 5, 2026