24V
A regular wall thermostat for all three series
One 24V kit (KSAIC0401230) lets a regular single-stage wall thermostat run all three series, on heads built after week 48 of 2018.
“24V Interface Kit KSAIC0401230” sheet, 328 42 0517 01, 05/2019COMFORTMAKER // Wall units
Three wall series, compared on what changes in your home
SoftSound® Deluxe DLCPRA · SoftSound® DLCSRA · Performance DLCERA
COMFORTMAKER // Wall units
At the same size, the head width, the outdoor unit, its weight, the refrigerant line length and the circuit change from one series to the next.
We offer three COMFORTMAKER wall series: SoftSound® Deluxe, SoftSound® and Performance. At 12,000 BTU/h, the narrowest head is the SoftSound (810 mm) and the lightest outdoor unit is the Performance (29.7 kg).
Page updated November 5, 2026
This page answers
Which of the three series fits your home: on the wall, outside and at the electrical panel?
Sold and installed by AirGreen.
We install in Montreal, Laval, Longueuil, the South Shore and the North Shore.
01 // The tool
Pick the size and the distance between the head and the outdoor unit. The three columns update: dimensions, weight, refrigerant line length, drain, circuit and published heat at −15 °C. The wall width is optional.
Size
Distance between head and outdoor unit
Free wall width for the head (optional)
Values published by COMFORTMAKER in the July 2020 catalogue (series tables, pp. 16, 18, 20–24, 34–36 and 40) and, for the SoftSound® Deluxe 18,000 and 24,000, in the January 2023 COMFORTMAKER brochure (pp. 14 and 18). The free-wall comparison uses the head width only: clearances are checked during the on-site assessment. Weights: published net weights.
SoftSound® Deluxe
DLCPRA 12,000
COMFORTMAKER catalogue, July 2020
SoftSound®
DLCSRA 12,000
COMFORTMAKER catalogue, July 2020
Performance
DLCERA 12,000
COMFORTMAKER catalogue, July 2020
At 12,000 BTU/h, the narrowest head is the SoftSound (810 mm) and the lightest outdoor unit is the Performance (29.7 kg). At 7.5 m, all three series stay within their published length.
The COMFORTMAKER shop
All three series, from 9,000 to 36,000 BTU/h. Price on quotation, after the on-site assessment.
02 // Did you know
24V
One 24V kit (KSAIC0401230) lets a regular single-stage wall thermostat run all three series, on heads built after week 48 of 2018.
“24V Interface Kit KSAIC0401230” sheet, 328 42 0517 01, 05/20192 sizes
Two outdoor cabinet sizes repeat from one series to another, with the same published dimensions: 845 × 702 × 363 mm for the SoftSound® Deluxe 9,000 and 12,000 and the SoftSound® 18,000; 800 × 554 × 333 mm for the SoftSound® 9,000 and 12,000 and the Performance 18,000.
COMFORTMAKER catalogue, July 2020, pp. 16, 21–22 and 34 (weights differ)725 / 813 mm
The Performance is the only series whose 9,000 and 12,000 heads are not the same width: 725 mm and 813 mm.
COMFORTMAKER catalogue, July 2020, p. 4003 // The comparison
At the same size, here is what the central heat pump publishes, next to the two wall series offered in 24,000 BTU/h, at −8.3 °C (17 °F).
| Value | SoftSound® Deluxe 24,000 | SoftSound® 24,000 | Central CSH624 + FXM4X24 |
|---|---|---|---|
| Rated heat at −8.3 °C | 15,450 BTU/h | 15,000 BTU/h | 14,200 BTU/h |
| COP at −8.3 °C | 3.00 | 2.35 | 2.60 |
| SEER (pre-2023 test basis) | 23.5 | 20.0 | 16 |
The right-hand column gives the published values for the brand-tested combination: the CSH624 outdoor unit with the FXM4X24 fan coil. We do not offer the Performance in 24,000 BTU/h. We do not compare sound values: the central system is rated with a different method. See COMFORTMAKER central heat pumps
COMFORTMAKER brochure, January 2023, p. 14; COMFORTMAKER catalogue, July 2020, p. 20; CSH6 sheet 428 41 6400 02, p. 15
04 // Published figures
| Model | Head width | Outdoor unit, net weight | Max. refrigerant lines | MCA / max fuse | Max. heat at −15 °C | SEER | Published heating |
|---|---|---|---|---|---|---|---|
| SoftSound® Deluxe 9,000 · DLCPRA | 895 mm | 48.8 kg | 30 m | 13 A / 15 A | 13,000 BTU/h | 40.0 | down to −30 °C |
| SoftSound® Deluxe 12,000 · DLCPRA | 895 mm | 49.2 kg | 30 m | 15 A / 20 A | 13,800 BTU/h | 30.0 | down to −30 °C |
| SoftSound® Deluxe 18,000 · DLCPRA | 1,259 mm | 61.4 kg | 30 m | 18 A / 30 A | 18,000 BTU/h | 28.2 | down to −30 °C |
| SoftSound® Deluxe 24,000 · DLCPRA | 1,259 mm | 65.8 kg | 30 m | 20 A / 30 A | 24,000 BTU/h | 23.5 | down to −30 °C |
| SoftSound® 9,000 · DLCSRA | 810 mm | 41.2 kg | 25 m | 9 A / 15 A | 10,700 BTU/h | 24.7 | down to −30 °C |
| SoftSound® 12,000 · DLCSRA | 810 mm | 41.6 kg | 25 m | 9 A / 15 A | 12,100 BTU/h | 21.5 | down to −30 °C |
| SoftSound® 18,000 · DLCSRA | 1,090 mm | 51.4 kg | 30 m | 17 A / 25 A | 20,700 BTU/h | 22.0 | down to −30 °C |
| SoftSound® 24,000 · DLCSRA | 1,090 mm | 64 kg | 30 m | 20 A / 30 A | 23,300 BTU/h | 20.0 | down to −30 °C |
| SoftSound® 36,000 · DLCSRA | 1,350 mm | 65 kg | 50 m | 25 A / 35 A | 23,400 BTU/h | 18.0 | down to −25 °C |
| Performance 9,000 · DLCERA | 725 mm | 28.6 kg | 25 m | 8 A / 15 A | 6,070 BTU/h | 17.6 | down to −17 °C |
| Performance 12,000 · DLCERA | 813 mm | 29.7 kg | 25 m | 10 A / 15 A | 8,880 BTU/h | 17.5 | down to −17 °C |
| Performance 18,000 · DLCERA | 974 mm | 36.1 kg | 30 m | 15 A / 20 A | 10,150 BTU/h | 17.5 | down to −17 °C |
SoftSound® Deluxe 18,000 and 24,000: COMFORTMAKER brochure, January 2023. SEER published on the pre-2023 test basis. MCA: minimum circuit ampacity; max fuse: the largest fuse or breaker allowed (printed as MOCP in the ductless catalogue).
COMFORTMAKER catalogue, July 2020, pp. 16, 18, 20–24, 34–36 and 40; COMFORTMAKER brochure, January 2023, pp. 14 and 18
05 // Good to know
Wi-Fi is added with a kit sold as an accessory; the kit depends on the series and, for the Performance, on the size: KSAIF0601AAA for the SoftSound® Deluxe head, KSAIF0501AAA for the SoftSound®, KSAIF0101AAA for the Performance 9,000 and 12,000, KSAIF0201AAA for the Performance 18,000. If you want to control the unit from your phone, tell us during the assessment and the kit goes on the quotation.
The catalogue prints two circuit values for each outdoor unit: the MCA, the minimum circuit ampacity, and the max fuse (MOCP), the largest fuse or breaker allowed. At 12,000 BTU/h, the SoftSound® Deluxe needs 15 A / 20 A, the SoftSound® 9 A / 15 A and the Performance 10 A / 15 A. We check the free space in your panel during the on-site assessment.
The free width on the wall, the route of the refrigerant lines to the outdoor unit, the height difference, where the unit can sit outside and the room in the panel. Those are exactly the points that change from one series to the next: the series and the size are decided there, not on a spec sheet.
06 // Warranty
The full terms are in the unit’s warranty certificate.
“Residential Warranties at a Glance”, COMFORTMAKER, AP-002-CM-00, 03/2023
AirGreen // COMFORTMAKER
07 // Questions
We do not rank the three series: they do not install the same way. At the same size, the head, the outdoor unit, the refrigerant line length and the circuit change. The “Which one fits your home?” tool puts them side by side; the series and the size are chosen during the on-site assessment, free and with no obligation.
Each series has its published heating range: down to −30 °C for the SoftSound® Deluxe and every SoftSound® except the 36,000 (down to −25 °C), down to −17 °C for the Performance. At 12,000 BTU/h, the published maximum heat at −15 °C is 13,800, 12,100 and 8,880 BTU/h. To put those steps in context, Montreal’s 1981–2010 normals (station 7025250) give an average daily minimum of −14.0 °C in January and 14.3 days a year below −20 °C.
At 12,000 BTU/h, the lowest published value for the head is 29 dB(A) (SoftSound® Deluxe), 26.1 dB(A) (SoftSound®) and 34 dB(A) (Performance); outside, the catalogue publishes 56.0, 54.6 and 57.4 dB(A). For scale, Québec.ca (“Noise measurement”, updated June 16, 2022) puts 40 dB(A) at “library, refrigerator, a quiet street at night”, “a peaceful area”, and 50 dB(A) at “moderate rain, washing machine”, “the beginning of disturbance”. COMFORTMAKER does not publish the test conditions for these values, and Québec.ca gives no distance, so the comparison is only a guide.
The catalogue publishes a maximum refrigerant line length for each size: 30 m for the whole SoftSound® Deluxe series; 25 m for the SoftSound® and Performance 9,000 and 12,000; 30 m for the SoftSound® 18,000 and 24,000 and the Performance 18,000. On those sizes, the published maximum lift ranges from 10 to 20 m. The 36,000 has its own, longer limit (see the table). The tool checks your distance against the limit for each size.
10 years on parts (limited warranty) when the unit is registered within 90 days of installation, otherwise 5 years, for the original owner in residential use. COMFORTMAKER does not cover labour.
The price is on quotation, after the on-site assessment: the series, the size, the refrigerant line length and the circuit change the job. The assessment is free and comes with no obligation.
AirGreen calculations (kW conversions, sums, percentage shares) are made on the published values and labelled as such.
AirGreen // Air conditioning and heating
We measure the wall, the route to the outdoor unit and the room in the panel, then tell you which series and which size fit.
Page updated November 5, 2026