AirGreenTRANE
Air handlersTRANE RunTru air handlers, 1.5 to 5 tonsSold and installed by AirGreen. We install across Montreal, Laval, Longueuil, the South Shore and the North Shore.
The whole TRANE space
TRANE air handlers

TRANE air handlers: the right match

The air handler is the indoor half of a central heat pump: blower, coil and, when needed, an electric heater added on site. 23 RunTru products, on R-410A or R-454B. The tool below shows which ones go with your heat pump, and the backup heat Trane approves.

Updated October 29, 2026. Figures from Trane’s documents and the sources listed at the bottom of the page.
23products on this page
24.0 kWstrongest approved backup, A5AHV006 and 007 at 240 V
12A5HP5 + A5AHV pairings certified ENERGY STAR
4families: A4AH4, A4AH5E, A4AH5V and A5AHV
Our reading of the figures

Refrigerant comes first. An R-454B A5HP5 goes with an A5AHV: at 3 tons, three pairings with an A5AHV are ENERGY STAR certified (AHRI 214296500, 214296502 and 214296504). For an A4HP4 or A4HP6, the tool keeps the A4AH4 and A4AH5 units whose range covers the size; none of these pairings has an AHRI number in ENERGY STAR or NEEP: we confirm it at the estimate. An E4HL5 has its own unit, the E4AH5E.

Sold and installed by AirGreenBackup heat from 3.84 to 24.0 kW at 240 VOn R-410A or R-454BFree on-site estimate
The models

The 23 TRANE air handlers

Price on quote, after the free on-site estimate.

R-454B · 4R-410A · 19
TRANE
TRANETRANE
01 · The right match

Which unit goes with your heat pump?

Pick the outdoor heat pump (A5HP5, E4HL5, A4HP4 or A4HP6) and its size. The tool keeps the units on this page whose Trane-published range covers that size, on the same refrigerant, with the certified pairings we found and the backup heat Trane approves.

Your outdoor heat pump
Its size

4 A5AHV units on this page go with a 3-ton A5HP5, 3 of them as ENERGY STAR certified pairings.

  • A5AHV003R-454B
    Published range
    1.5 to 3 tons
    Cabinet H × W × D
    1,187 × 470 × 537 mm
    Blower
    variable speed
    Approved backup heat
    3.84 to 14.4 kW at 240 V (2.88 to 10.8 kW at 208 V)
    ENERGY STAR pairing
    none in the list
    See the product
  • A5AHV004R-454B
    Published range
    2.5 to 4 tons
    Cabinet H × W × D
    1,305 × 597 × 537 mm
    Blower
    variable speed
    Approved backup heat
    3.84 to 19.2 kW at 240 V (2.88 to 14.4 kW at 208 V)
    ENERGY STAR pairing
    AHRI 214296500
    See the product
  • A5AHV006R-454B
    Published range
    3 to 5 tons
    Cabinet H × W × D
    1,457 × 597 × 537 mm
    Blower
    variable speed
    Approved backup heat
    3.84 to 24.0 kW at 240 V (2.88 to 18.0 kW at 208 V)
    ENERGY STAR pairing
    AHRI 214296502
    See the product
  • A5AHV007R-454B
    Published range
    3 to 5 tons
    Cabinet H × W × D
    1,457 × 597 × 537 mm
    Blower
    variable speed
    Approved backup heat
    3.84 to 24.0 kW at 240 V (2.88 to 18.0 kW at 208 V)
    ENERGY STAR pairing
    AHRI 214296504
    See the product

Ranges: Trane data sheet AHR-PSD011C-EN (July 2026). Pairings: ENERGY STAR list, checked October 28, 2026. The pairing and its AHRI certificate are confirmed at the estimate.

TRANETRANE
02 · The units

The units on this page, model by model

The A5AHV and A4AH5 codes are the ones Trane prints; the A4AH4 codes are those of the products sold here, which the 2021 guide prints with series letter B. The “4” or “5” in an A4AH4 or A4AH5 is the SEER2 tier of the matched system, 14.3 or 15.2 (2024 key; the 2021 A4AH4 units date from the SEER era), not a rating of the air handler alone.

Trane modelBlowerPublished rangeCabinet H × W × DProduct
A5AHV · R-454B
A5AHV003A1B30Avariable speed1.5 to 3 tons1,187 × 470 × 537 mmSee the product
A5AHV004A1D30Avariable speed2.5 to 4 tons1,305 × 597 × 537 mmSee the product
A5AHV006A1D30Avariable speed3 to 5 tons1,457 × 597 × 537 mmSee the product
A5AHV007A1D30Avariable speed3 to 5 tons1,457 × 597 × 537 mmSee the product
A4AH5V · R-410A
A4AH5V24A1B30Avariable speed1.5 to 2.5 tons1,188 × 470 × 537 mmSee the product
A4AH5V30A1B30Avariable speed2 to 3 tons1,188 × 470 × 537 mmSee the product
A4AH5V36A1C30Avariable speed2 to 3.5 tons1,302 × 597 × 537 mmSee the product
A4AH5V48A1C30Avariable speed3 to 5 tons1,458 × 597 × 537 mmSee the product
A4AH5E · R-410A
A4AH5E19A1B30Aconstant-torque ECM1 to 2 tons1,148 × 470 × 537 mmSee the product
A4AH5E31A1B30Aconstant-torque ECM1.5 to 3 tons1,188 × 470 × 537 mmSee the product
A4AH5E43A1C30Aconstant-torque ECM3 to 4 tons1,302 × 597 × 537 mmSee the product
A4AH5E49A1C30Aconstant-torque ECM3.5 to 5 tons1,458 × 597 × 537 mmSee the product
A4AH5E61A1C30Aconstant-torque ECM3.5 to 5 tons1,458 × 597 × 537 mmSee the product
A4AH4 · R-410A · one nominal size per model (2021 RunTru guide)
A4AH4P18A1B60APSC motor1.5 ton1,144 × 470 × 537 mmSee the product
A4AH4P24A1B60APSC motor2 tons1,144 × 470 × 537 mmSee the product
A4AH4P30A1B60APSC motor2.5 tons1,144 × 470 × 537 mmSee the product
A4AH4P36A1B30APSC motor3 tons1,144 × 470 × 537 mmSee the product
A4AH4E42A1C30Aconstant-torque ECM3.5 tons1,302 × 597 × 537 mmSee the product
A4AH4E48A1C30Aconstant-torque ECM4 tons1,302 × 597 × 537 mmSee the product
A4AH4E60A1C30Aconstant-torque ECM5 tons1,302 × 597 × 537 mmSee the product

Sources: Trane data sheet AHR-PSD011C-EN (July 2026) for the A5AHV; RunTru catalogs 22-8301-36 (2023) and 22-8301-37 (2024), RTAH-1-B, for the A4AH5; RunTru guide 26-1067-02 (2021) for the A4AH4, which gives one nominal size per model. Trane gives dimensions in inches, converted here to millimetres.

TRANETRANE
03 · R-410A or R-454B

At 3 tons: the A4AH5V36 against the A5AHV004

Two of the variable-speed units that cover 3 tons, one on R-410A, the other on R-454B. The cabinet is almost the same (1,302 against 1,305 mm high); what changes is the refrigerant, the connections and the certified pairing.

Trane figure
A4AH5V36
A5AHV004
Refrigerant
R-410A
R-454B
Published range
2 to 3.5 tons
2.5 to 4 tons
Blower
variable speed
variable speed, ECM
Metering
thermal expansion valve
R-454B thermal expansion valve
Cabinet H × W × D
1,302 × 597 × 537 mm
1,305 × 597 × 537 mm
Shipping weight
145 lb (65.8 kg)
155 lb (70.3 kg)
Unit connections, gas / liquid
3/4 / 3/8 in
7/8 / 3/8 in
Factory-installed leak sensor
none listed
yes
ENERGY STAR pairing at 3 tons
none found
A5HP5036, AHRI 214296500

Sources: RunTru catalogue 22-8301-37, RTAH-1-B (2024), for the A4AH5V36; data sheet AHR-PSD011C-EN (July 2026) and guide AHR-SVX006C-EN (August 2026) for the A5AHV004; ENERGY STAR list checked October 28, 2026; pounds converted to kilograms.

TRANETRANE
04 · Backup heat

BAYHTR electric heaters, at 240 and 208 V

Trane sells its heaters under a trade name in kilowatts. The table gives what it publishes for each one at 240 and 208 V, and which A5AHV each is approved for. Every BAYHTR heater is fitted on site.

HeaterTrade nameAt 240 VAt 208 VA5AHV003A5AHV004A5AHV006, 007
BAYHTR15044 kW3.84 kW (13,100 BTU/h)2.88 kWapprovedapprovedapproved
BAYHTR15055 kW4.80 kW (16,400 BTU/h)3.60 kWapprovedapprovedapproved
BAYHTR15088 kW7.68 kW (26,200 BTU/h)5.76 kWapprovedapprovedapproved
BAYHTR151010 kW9.60 kW (32,800 BTU/h)7.20 kWapprovedapprovedapproved
BAYHTR151715 kW14.4 kW (49,200 BTU/h)10.8 kWapprovedapprovedapproved
BAYHTR152320 kW19.2 kW (65,500 BTU/h)14.4 kW—approvedapproved
BAYHTR152525 kW24.0 kW (81,900 BTU/h)18.0 kW——approved

Sources: RunTru catalogue 22-8301-37, RTAH-3, and Trane guide AHR-SVN001A-EN (June 19, 2025), Table 1, for the outputs; data sheet AHR-PSD011C-EN (July 2026), Table 1, for the approvals per A5AHV. For the A4AH4 and A4AH5, the approved heater depends on the cabinet in Trane’s BAYHTR matrix; the quote names it.

TRANETRANE
05 · Installation

What Trane requires for an A5AHV

R-454B is an A2L refrigerant: the A5AHV guide adds rules a proper installation follows.

  • Service clearances: 51 mm (2 in) on the sides, 533 mm (21 in) in front, none at the back.Guide AHR-SVX006C-EN, p. 12
  • Filter: a remote filter, installed ahead of the coil; the A5AHV has no filter rack.Guide AHR-SVX006C-EN, p. 15; data sheet AHR-PSD011C-EN
  • Drain: primary and auxiliary, 3/4 in NPT, trap outside the unit, slope of at least 21 mm per metre (1/4 in per foot).Guide AHR-SVX006C-EN, p. 13
  • Leak sensor: clipped to the primary drain pan; for any position other than upflow it must be moved (horizontal right: onto the secondary pan). If it detects R-454B, the unit starts its blower to dilute the gas, opens the zoning dampers and stops the outdoor compressor.Guide AHR-SVX006C-EN, pp. 10, 17 and 20
  • Conditioned area: depending on the R-454B charge, at least 5.85 m² (63 sq ft) for 1.81 kg (4 lb), and 29.26 m² (315 sq ft) for 9.07 kg (20 lb), at sea level.Guide AHR-SVX006C-EN, Table 1, p. 10
  • In 5 tons, horizontal or downflow: 850 L/s (1,800 cfm) at most, so condensate is not blown out of the pan.Data sheet AHR-PSD011C-EN, Table 11, note b; guide, p. 27
TRANETRANE
06 · Did you know

Three details from Trane’s own documents

01

The “31” in A4AH5E31 is not a tonnage: this cabinet takes a heat pump from 1.5 to 3 tons.

RunTru catalogs 22-8301-36 and 22-8301-37, RTAH-1-B
02

An A5AHV is set with eight DIP switches: 1 to 4 set the cooling airflow, 5 and 6 the blower off-delay, 7 and 8 the electric backup.

Guide AHR-SVX006C-EN, p. 16
03

Every A5AHV has a factory-installed R-454B leak sensor; the unit must stay powered at all times, except during servicing.

Guide AHR-SVX006C-EN, p. 10
07 · Who does what

The unit is TRANE, the installation is AirGreen

TRANE

What Trane brings

  • The RunTru units, their sheets and their matching ranges
  • Its limited parts warranty: in most cases 5 years, or 10 years if the unit is registered within 60 days of installation
  • The installation rules in its guides, including the R-454B ones
08 · Questions

What people ask us about TRANE air handlers

Why “air handler”?
These are RunTru air handlers: the blower and indoor coil of a central heat pump; the BAYHTR electric element is backup only, added on site. Trane sells it separately.
How much backup heat should I choose?
Depending on the cabinet, Trane approves heaters from 3.84 kW to 24.0 kW at 240 V on the A5AHV; at 208 V, each one gives 25% less. AirGreen’s on-site visit sets the BAYHTR heater, with the heat pump and the home’s electrical service.
Can an A5AHV go with my R-410A heat pump?
The A5AHV is built for R-454B: Trane gives it an R-454B thermal expansion valve, and its ENERGY STAR pairings are with the A5HP5. For an R-410A heat pump, the A4AH4 and A4AH5 units on this page are R-410A.
Can an A5AHV or A4AH go horizontal or downflow?
The A4AH4, A4AH5 and A5AHV are multi-position: upflow, downflow or horizontal, left or right; the A5AHV ships set for upflow. The E4AH5E that comes with the E4HL5 goes upflow or horizontal only. For a downflow A5AHV with an electric heater, Trane says a downflow sub-base may be required (guide AHR-SVX006C-EN, p. 13).
What warranty do these RunTru units have?
RunTru’s parts warranty: in most cases 5 years, or 10 years if the unit is registered within 60 days of installation (RunTru line: 1-855-956-5685). An A5AHV or A4AH has no compressor: it sits in the outdoor unit. Labour is not covered by Trane; AirGreen guarantees it for 6 years on installations done since October 5, 2026.
Is there a LogisVert grant on an air handler?
Not on the unit alone: LogisVert targets the heat pump, and for a heat pump installed since November 26, 2025, Hydro-Québec requires ENERGY STAR certification (participation guide, version 1.10). So the pairing is what counts: the tool above shows the certified A5HP5 + A5AHV pairings, and the central heat pump page gives the indicative amount of the pairing on our product pages, size by size. Only Hydro-Québec confirms the assistance granted.
What size for my home?
AirGreen’s on-site visit sets it: the heat pump first, then the air handler whose range covers it, then the backup heater, and the written quote names all three.
AirGreen
AirGreen × TRANE

A TRANE air handler in your home, installed by AirGreen

We come and look at the heat pump, the ducts and the electrical service; the written quote names the unit, its pairing and the backup heater.

RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16. Gas and oil work: a partner holding the required licence.
On-site estimateFree, with a written quote.
Showroom1370 Joliot-Curie Street, Suite 712, Boucherville.
HoursMonday to Thursday, 8 a.m. to 6 p.m.; Friday, 8 a.m. to 4 p.m.
AirGreenTRANESold and installed by AirGreen