AirGreenTRANE
ProSpace PTACTRANE ProSpace PTAC units, R-32 and R-410A, 7,000 to 15,000 BTU/hSold and installed by AirGreen. We install across Montreal, Laval, Longueuil, the South Shore and the North Shore.
The whole TRANE space
TRANE ProSpace PTAC

TRANE ProSpace PTAC: the right model for your sleeve, and the right cord

16 ProSpace units, 7,000 to 15,000 BTU/h, to replace a unit in its wall sleeve. On the R-32 models, the power cord does not ship with the unit, and it sets the size of the electric heater: pick the size, the type and the cord, and the tool gives what Trane allows.

Updated October 29, 2026. Figures from Trane’s manual and the sources listed at the bottom of the page.
16models on this page
3Trane cords for the R-32 models, sold separately
5.0 kWlargest R-32 heater, on the 12,000 and 15,000 only
10 °CR-32 factory freeze guard: below 4.4 °C in the room, the heater warms it back to 10 °C
Our reading of the figures

On an R-32 ProSpace, the cord sets the heater size, and the 30 A cord fits the 12,000 and 15,000 BTU/h only. So before choosing, we look at the wall outlet and its circuit.

Sold and installed by AirGreenR-32: cord sold separatelyG generation on R-32, F on R-410AFree on-site estimate
The models

The 16 TRANE ProSpace PTAC units

Price on quote, after the free on-site estimate.

R-32, G generation · 8R-410A, F generation · 8
TRANE
TRANETRANE
01 · The cord decides

Which cord, and which electric heater?

Pick the size, the type and the cord. The tool covers the eight R-32 ProSpace units (G generation), the ones whose manual Trane publishes online.

Size
Type
Cord
Trane’s cord
PWR0028820 A cord

NEMA 6-20P plug · 3.5 kW heater: 3,450 W at 230 V, 2,830 W at 208 V

The three ProSpace cords

  • 15 A · PWR00286 · 6-15P2.5 kW
  • 20 A · PWR00288 · 6-20P3.5 kW
  • 30 A · PWR00290 · 6-30P5.0 kW

The 30 A cord fits the 12,000 and 15,000 BTU/h only.

PTHG1201HAA

Function
heat pump with electric heat
Cooling, 208 / 230 V
11,900 / 12,100 BTU/h
Heat pump heating
10,700 / 10,900 BTU/h
EER
11.8 / 11.6
Largest heater
5.0 kW
Cords allowed
15, 20 or 30 A
See the PTHG1201HAA
The model number, read with Trane’s key
PTpackaged terminal unitHheat pump with electric heatGR-32 refrigerant (F = R-410A)12012,000 Btu class1208/230 VH5.0 kW heater at mostAAfirst design

Source: Trane manual PART-SVX007A-EN (September 2024), model key p. 7, Tables 3 and 4 pp. 10–11, heater power at 230 and 208 V pp. 8–9. The cord does not ship with the unit, and the 250 V outlet must match its plug.

TRANETRANE
02 · The R-32 models

The eight G-generation ProSpace units, size by size

Heat pump PTHG or air conditioner PTEG: the figures are those of Trane’s manual. Where two values are split by a slash, the first is at 208 V, the second at 230 V.

Trane figure7,000 BTU/h9,000 BTU/h12,000 BTU/h15,000 BTU/h
ModelsPTHG0701GAA
PTEG0701GAA
PTHG0901GAA
PTEG0901GAA
PTHG1201HAA
PTEG1201HAA
PTHG1501HAA
PTEG1501HAA
Cooling, PTHG heat pump7,200 / 7,400 BTU/h9,400 / 9,700 BTU/h11,900 / 12,100 BTU/h14,200 / 14,600 BTU/h
Cooling, PTEG air conditioner7,200 / 7,400 BTU/h9,900 / 10,200 BTU/h12,100 / 12,300 BTU/h14,400 / 14,700 BTU/h
Heat pump heating, PTHG5,800 / 6,000 BTU/h8,200 / 8,500 BTU/h10,700 / 10,900 BTU/h13,300 / 13,800 BTU/h
EER, PTHG · PTEG13.0 · 13.312.1 · 12.511.8 / 11.6 · 11.8 / 11.610.4 · 10.6 / 10.4
Largest heater3.5 kW3.5 kW5.0 kW5.0 kW
Cords allowed15 or 20 A15 or 20 A15, 20 or 30 A15, 20 or 30 A
Dehumidification0.80 L/h1.00 L/h1.30 L/h1.50 L/h
Application area, per Trane10 to 16 m² (108–172 ft²)12 to 18 m² (129–194 ft²)16 to 24 m² (172–258 ft²)21 to 31 m² (226–334 ft²)
Sound in dB(A), low · high fan46 (low) · 50 (high)46 (low) · 50 (high)50 (low) · 53 (high)50 (low) · 53 (high)
Net weight, PTHG · PTEG50.8 · 49.9 kg52.2 · 49.9 kg54.0 · 52.2 kg54.4 · 52.2 kg
R-32 charge, PTHG · PTEG0.77 · 0.50 kg0.68 · 0.50 kg0.82 · 0.59 kg0.86 · 0.54 kg
The productThe heat pumpThe air conditionerThe heat pumpThe air conditionerThe heat pumpThe air conditionerThe heat pumpThe air conditioner

Source: Trane manual PART-SVX007A-EN (September 2024), pp. 8–9. One value where 208 and 230 V are the same. Sound as sound pressure. Dehumidification and area converted by us (US pints and ft²). The area is Trane’s guideline: the on-site visit sets the size. For the 8 R-410A PTEF and PTHF units, see the questions below.

TRANETRANE
03 · Heat pump or air conditioner

At 12,000 BTU/h: PTHG1201HAA or PTEG1201HAA

Same 12,000 BTU/h class, same cords, same heaters. What changes: the heat pump heats with its compressor first, a mode Trane publishes for 13 to 23.9 °C outdoors (p. 6).

Trane figure
Heat pump PTHG1201HAA
Air conditioner PTEG1201HAA
Cooling208 / 230 V
11,900 / 12,100 BTU/h
12,100 / 12,300 BTU/h
EER208 / 230 V
11.8 / 11.6
11.8 / 11.6
Heat pump heating208 / 230 V
10,700 / 10,900 BTU/h
none
Electric heaterTrane manual
set by the cord
set by the cord
Cooling current208 / 230 V
4.9 / 4.6 A
5.0 / 4.7 A
Net weightTrane manual
54.0 kg (119 lb)
52.2 kg (115 lb)
R-32 chargeTrane manual
0.82 kg (1.8 lb)
0.59 kg (1.3 lb)

Source: Trane manual PART-SVX007A-EN (September 2024), pp. 8–9, p. 6 and p. 21.

TRANETRANE
04 · Replacement

Replacing a PTAC in its sleeve: what Trane asks for

The installation rules in the R-32 ProSpace manual. A replacement is checked against them.

  • Sleeve: for a replacement, Trane recommends a Trane sleeve. The ProSpace can go into another make’s similar sleeve if the outdoor airflow is neither blocked nor recirculated.Manual PART-SVX007A-EN, p. 14
  • Grille: the outdoor grille must be in place on the sleeve. With another make’s grille, its foam baffles come out, and the factory foam seals must close the gap between the grille and the outdoor coil.Manual PART-SVX007A-EN, p. 14
  • Fitting: the unit slides level into the sleeve until the foam seal presses on the front, then is fastened with four supplied screws; it is pitched 1/4 in (6 mm) toward the outside.Manual PART-SVX007A-EN, pp. 15, 35
  • Power: no extension cord, and the 250 V outlet must match the cord’s plug and stay within its reach.Manual PART-SVX007A-EN, pp. 4, 10
  • Wall thermostat: optional, field supplied and enabled by DIP switch 2; 18 to 20 gauge solid wire, and no dry mode with a wall thermostat.Manual PART-SVX007A-EN, pp. 18–20
  • Warranty: Trane states that a failure due to improper installation is not covered by the warranty, nor are defects in the sleeve.Manual PART-SVX007A-EN, p. 14

The sleeve and grille dimensions are in two separate documents (PTAC-SVN028 and PTAC-SVN027), which are not online at Trane: we measure the sleeve at the visit.

TRANETRANE
05 · Did you know

Three details from the ProSpace manual

01

On the PTHG heat pump, the electric heater and the compressor never run at the same time. The room decides: if it falls 2.8 °C (5 °F) below the setpoint, the compressor stops and the heater takes over. The heater also starts when a protection keeps the compressor from running, for example against frost in cold weather.

Manual PART-SVX007A-EN, pp. 21 and 34
02

There are two filters, to clean at least every 30 days, or more often depending on use.

Manual PART-SVX007A-EN, p. 25
03

The owner can lock the setpoint range, for example to 20–24 °C (DIP switches 5 and 6); from the factory it runs from 16 to 30 °C.

Manual PART-SVX007A-EN, p. 16
06 · Who does what

The unit is TRANE, the installation is AirGreen

TRANE

What Trane brings

  • The ProSpace units and their installation, operation and maintenance manual
  • The PWR00286, PWR00288 and PWR00290 cords, sold separately
  • Its published G-generation warranty: 5 years on parts and 5 years on the sealed system (replacement)
07 · Questions

What people ask us about TRANE PTAC units

Which cord do I need?
The one that matches the wall outlet and its circuit. Trane offers three ProSpace cords, sold separately: 15 A (PWR00286, NEMA 6-15P plug, 2.5 kW heater), 20 A (PWR00288, 6-20P, 3.5 kW) and 30 A (PWR00290, 6-30P, 5.0 kW), the last one barred on sizes 07 and 09. The manual also cites “national codes”, which require an arc-fault or leakage-current detection device on every 208/230 V cord.
Will my old sleeve do?
It is checked on site: for a replacement, Trane recommends a Trane sleeve; the ProSpace can go into another make’s similar sleeve if the outdoor airflow is neither blocked nor recirculated, with the grille in place. The sleeve dimensions are not in the ProSpace manual: we measure it at the visit.
PTHG heat pump or PTEG air conditioner?
Both cool and both take the same electric heaters. The PTHG heat pump heats with its compressor first, a mode Trane publishes for 13 to 23.9 °C outdoors (p. 6): on the 12,000, 10,700 / 10,900 BTU/h at 208 / 230 V. The heater takes over when the room falls 2.8 °C below the setpoint, or when a protection keeps the compressor from running, for example against frost in cold weather. The PTEG air conditioner heats with its heater only.
What about the R-410A models, PTEF and PTHF?
They are F-generation ProSpace units: in Trane’s key, the fourth letter of the model number gives the generation, F for R-410A and G for R-32. No F-generation data sheet is online at Trane (searched October 28, 2026), so we do not give their figures as Trane’s, and the heater and the cord are confirmed on the unit’s nameplate, at the visit.
Can it go in any room?
No. For these R-32 units, Trane asks for a room with more than 4 m² (43 ft²) of floor area, and bars running them in damp rooms such as a bathroom or a laundry room.
What warranty?
For the G generation, Trane’s manual states 5 years on parts and 5 years on the sealed system (replacement). For the F generation, Trane’s 2020 sales brochure states 5 years on parts, 1 year of unit replacement and 5 years on accessories; the PTAC warranty certificate (PTACSVW003) is not in Trane’s online library. No Trane document we read mentions labour. 6 years on labour, guaranteed by AirGreen, for installations done since October 5, 2026.
Is there a LogisVert grant?
No, under the current rules. Hydro-Québec’s LogisVert residential guide (version 1.10, September 15, 2026) covers a two-unit central or wall air-source heat pump, ENERGY STAR certified, and a PTAC is a single packaged unit. PTAC units are not among the ENERGY STAR certified heat pumps. Only Hydro-Québec confirms the assistance granted.
AirGreen
AirGreen × TRANE

A ProSpace in your wall sleeve, installed by AirGreen

One visit to see the sleeve, the grille and the outlet; the written quote says which ProSpace and which cord.

RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16. Gas and oil work: a partner holding the required licence.
On-site estimateFree, with a written quote.
Showroom1370 Joliot-Curie Street, Suite 712, Boucherville.
HoursMonday to Thursday, 8 a.m. to 6 p.m.; Friday, 8 a.m. to 4 p.m.
AirGreenTRANESold and installed by AirGreen