TRANE RunTru central heat pumps: what the model number says
28 models in four RunTru families, 1.5 to 5 tons. On the nameplate, every character of the model number has a meaning in the key Trane publishes: brand, refrigerant, family, efficiency, capacity. Type yours or pick a family: the tool reads it, then sets out what Trane publishes for that family.
Updated October 29, 2026. Figures from Trane’s documents and the sources listed at the bottom of the page.Two characters tell you almost everything. The 2nd gives the refrigerant: 5 for the A5HP5’s R-454B, 4 for the R-410A of the other three families. The 5th gives the SEER2 efficiency tier: 3, 4 or 5 in Trane’s current key. Two families sold here predate SEER2: the A4HP6, whose “6” is not in the current key (the 2021 RunTru guide calls it “16 SEER”), and the 2021 A4HP4, whose “4” means 14 SEER, not 14.3 SEER2. Among the pairings on our product sheets, only the A5HP5’s are ENERGY STAR certified, from 1.5 to 4 tons.
The 28 TRANE central heat pumps
Price on quote, after the free on-site estimate.
What each character means
Pick a family or type the number on the outdoor unit’s nameplate. The tool follows the RunTru model nomenclature Trane publishes (22-8301-37, 2024), confirmed by the 2025 ODR-PSD035A-EN product data.
The key, position by position
- 1 · Brand
- RunTru (by Trane)
- 2 · Refrigerant
- R-454B
- 3–4 · Product family
- Heat pump
- 5 · Nominal efficiency
- 15.2 SEER2
- 6–8 · Nominal capacity
- 36,000 BTU/h, 3 tons
- 9 · Major development sequence
- Sequence A
- 10 · Electrical
- 208-230 V, single phase, 60 Hz
- 11–13 · Secondary function
- None
- 14 · Minor design sequence
- Sequence A
What Trane publishes for the A5HP5
- Refrigerant
- R-454B, GWP 470 (A2L class)
- Compressor
- Scroll, single stage
- Heating
- Published range down to −17.8 °C outdoors
- ENERGY STAR, with the A5AHV on our sheets
- 1.5 tons · yes2 tons · yes2.5 tons · yes3 tons · yes3.5 tons · yes4 tons · yes5 tons · no
At 3 tons: ENERGY STAR certified with the A5AHV004 on our product sheet (AHRI 214296500, SEER2 16.0), “Most Efficient” designation. Published heat: 22,000 BTU/h at −8.3 °C, 17,500 BTU/h at −15 °C. LogisVert: about $1,100, an indicative amount ($50 per 1,000 BTU/h at −8 °C, LogisVert guide v1.10). Only Hydro-Québec confirms the assistance granted.
Sources: RunTru model nomenclature 22-8301-37 (effective January 1, 2024); product data ODR-PSD035A-EN (June 26, 2025); RunTru guide 26-1067-02 (2021); ENERGY STAR and NEEP lists read on October 28, 2026. The LogisVert amount uses the guide v1.10 rule on the heat ENERGY STAR publishes at −8.3 °C.
A5HP5, E4HL5, A4HP4, A4HP6: what Trane publishes
The most recent in Trane’s catalogue is the A5HP5: it is in the May 1, 2026 Product Handbook, which does not list the other three. The column of the family read above (the A5HP5 at first) is highlighted.
| Trane figure | A5HP5 | E4HL5 | A4HP4 | A4HP6 |
|---|---|---|---|---|
| Trane’s name | A5HP5 Heat Pump | Side Discharge Heat Pump | “14 SEER HP” | “16 SEER Heat Pumps” |
| Latest Trane catalogue listing it | 2026 Product Handbook (May 1, 2026) | catalogue effective January 1, 2024 | catalogue effective January 1, 2024, for the SEER2 generation (sequence D) only; the 2021 generation on our sheets is in the 2021 RunTru guide | June 2022 catalogue |
| Reference document | 2025 product data | 2023 installer’s guide | 2021 RunTru guide | 2021 RunTru guide |
| Refrigerant | R-454B (GWP 470) | R-410A (GWP 2,088) | R-410A, per the key | R-410A, per the key |
| Compressor | scroll, single stage | variable speed | scroll | scroll |
| Published heating | range down to −17.8 °C; lockout at −24.4 °C | down to −20 °C | — | — |
| SEER2, pairings on our sheets | 15.2 to 16.0 | 15.2 | — | — |
| ENERGY STAR, pairings on our sheets | yes, 1.5 to 4 tons | no | no | no |
| Liquid line | 5/16 in | 3/8 in | — | — |
| Longest line set | 45.7 m | 30.5 m to 50 m | — | — |
| The models | See the grid | See the grid | See the grid | See the grid |
—: value missing from the Trane documents we could read. Sources: ODR-PSD035A-EN (2025) and ODR-SVX011C-EN (2026) for the A5HP5; 88-E4HL5001-1B-EN (2023) and sell sheet 26-7319-02 (2024) for the E4HL5; RunTru guide 26-1067-02 (2021) and sheets 26-1055-05 (2023) for the A4HP4 and A4HP6; ENERGY STAR and NEEP for the pairings.
At 3 tons, the two certified pairings on our product sheets
Two AHRI-certified pairings: the E4HL5036 with the E4AH5E36, on the NEEP list, and the A5HP5036 with the A5AHV004, ENERGY STAR certified. The figures are those lists’ own, AHRI number by AHRI number.
AHRI 211749850
AHRI 214296500
Sources: NEEP, record 438303 (AHRI 211749850); ENERGY STAR, AHRI 214296500; 88-E4HL5001-1B-EN and ODR-SVX011C-EN for the heating limits. HSPF2: NEEP gives 8.1 in region IV and 6.9 in region V for the E4HL5; ENERGY STAR publishes a single value for the A5HP5. LogisVert: indicative amount, $50 per 1,000 BTU/h at −8 °C (guide v1.10) applied to the 22,000 BTU/h published at −8.3 °C. Only Hydro-Québec confirms the assistance granted.
What Trane requires at installation, family by family
The two families whose installation guide we read on Trane’s site. An A5HP5 or E4HL5 installation is checked against these rules.
A5HP5 (R-454B)
- Trane requires a leak mitigation board in every system, because R-454B is an A2L (lower flammability) refrigerant.
- R-454B leak detectors only; brazed joints, never soldered.
- Evacuation to 350 microns or below.
- Liquid line 5/16 in, no more than 45.7 m in total and 15.2 m of height difference.
- Where snow builds up, raise the unit 76 to 305 mm and keep the base-pan drain holes open.
Guide ODR-SVX011C-EN (September 25, 2026)
E4HL5 (R-410A)
- Evacuation to 350 microns or below, after a leak test at 150 psig with dry nitrogen.
- Liquid line 3/8 in: no more than 30.5 m and 15.2 m of height difference from 1.5 to 3 tons, 50 m and 29.9 m from 3.5 to 5 tons.
- Copper conductors only, on a dedicated circuit for the E4HL5.
- Defrost lasts 2 to 10 minutes, and the indoor fan stops meanwhile.
Guide 88-E4HL5001-1B-EN (September 8, 2023)
Three details from the RunTru documents
The 3- and 5-ton E4HL5 units have a capacity switch: set before installation, it brings them down to 75% (2 or 4 tons, per Trane).
Catalog 22-8301-36; guide 88-E4HL5001-1B-EN, Table 10The A5HP5’s compressor goes into protective lockout at −24.4 °C (−12 °F) and restarts at −19.4 °C (−3 °F).
Guide ODR-SVX011C-EN, Table 15The A5HP5’s casing passes a 1,000-hour salt spray test.
Product data ODR-PSD035A-EN (2025)The unit is TRANE, the installation is AirGreen
What Trane brings
- The RunTru heat pumps, their product data and their model key
- Its limited warranty on functional parts: in most cases 5 years, or 10 years if the unit is registered within 60 days of installation
- The installation rules in its guides, including the R-454B rules for the A5HP5
What AirGreen brings
- The free on-site estimate and the written quote
- Installation by our refrigeration technicians, under AirGreen’s RBQ licence 5645-9605-01
- Commissioning the heat pump and its air handler
- 6 years on labour, guaranteed by AirGreen, for installations done since October 5, 2026
What people ask us about TRANE central heat pumps
Which one heats in the coldest weather?
Which ones are ENERGY STAR certified?
Is there a LogisVert grant?
Why can’t the A4HP6 be read with the current key?
R-410A or R-454B: what changes?
What warranty comes with a RunTru central heat pump?
What RunTru size for my house?
A TRANE central heat pump in your home, installed by AirGreen
We come and see the house, the ducts and the indoor unit in place; the written quote says which RunTru family and which size.
Sources checked on October 28, 2026
- Trane, RunTru Model Nomenclature (RTNOM), 22-8301-37 (effective January 1, 2024)
- Trane, Split System Heat Pump A5HP5, product data ODR-PSD035A-EN (June 26, 2025)
- Trane, A5HP5 heat pumps installation guide, ODR-SVX011C-EN (September 25, 2026)
- Trane, E4HL5 installation manual, 88-E4HL5001-1B-EN (September 8, 2023)
- RunTru, Side Discharge Heat Pump and Air Handler sell sheet, 26-7319-02 (2024)
- Trane, RunTru Split System Heat Pumps catalogue, 22-8301-36 (effective January 1, 2023)
- Trane, catalogue table of contents, 22-8301-37 (effective January 1, 2024)
- Trane, catalogue 22-8301-35, table of contents (June 24, 2022)
- Trane, 2026 Product Handbook, 22-8301-39, table of contents (May 1, 2026)
- Trane, RunTru Guide, 26-1067-02 (2021)
- RunTru, Outdoor Series sell sheets, 26-1055-05 (2023)
- RunTru, Warranty page
- ENERGY STAR, certified heat pumps (dataset w7cv-9xjt)
- NEEP, cold climate air-source heat pump list (ccASHP)
- Hydro-Québec, LogisVert residential, conditions page
- Hydro-Québec, LogisVert residential participation guide, version 1.10 (September 15, 2026, in French)