Sharp dual-zone: two rooms, one unit outside.
Three Sharp dual-zones: the CU (down to -30°C, coming soon to AirGreen), the BU (down to -27°C) and the TU (R-410A, down to -20°C according to Sharp). The CU and BU get $3,000 in LogisVert. With two 18,000 heads, Sharp’s table gives 13,000 BTU/h to each room. We install them in Montreal, Laval, Longueuil, the South Shore and the North Shore.
Which multi-zone system?
ENERGY STAR and NEEP, Oct. 8, 2026; Hydro-Québec, Oct. 6, 2026; Sharp spec sheets. -20°C for the TU dual-zone: according to Sharp.
Two heads: see how Sharp shares the heat.
With the AE-X3M24CU compressor, Sharp plans for every pair of CU heads of 9,000, 12,000 and 18,000 BTU/h. Choose your two heads.
Room 1
Room 2
Rated heating per head (8.3°C outdoors), Sharp capacity table for the AE-X3M24CU. CHU units don’t connect to a multi-zone system (Sharp CU/CHU manual).
—
Up to 25 m of line per head and 70 m in total, with added refrigerant, according to Sharp.
CU, BU or TU as a dual-zone.
Green marks the better value on each line.
| Sharp system | CU multi-zone | BU multi-zone | TU multi-zone |
|---|---|---|---|
| Outdoor unit | AE-X3M24CUR-32 | AE-X3M24BUR-32 | AE-X2M20TUR-410A |
| Indoor heads | AY-XPC9CU · AY-XPC12CU · AY-XPC18CU (-B) | AY-XPC9BU · AY-XPC12BU · AY-XPC18BU | AY-XPM07TU · AY-XPC09TU · AY-XPC12TU |
| Rooms | 2 or 3 | 2 or 3 | 2 |
| Heats down to | -30°CSharp spec sheet | -27°Caccording to Sharp | -20°Caccording to Sharp |
| Heat at -8°C | 25,000 BTU/h | 25,000 BTU/h | Not certified |
| Heat at -15°C | 21,200 BTU/h | 21,200 BTU/h | — |
| SEER2 / HSPF2 | 24.0 / 11.5 | 24.0 / 11.5 | — |
| ENERGY STAR | Yes | Yes | No |
| LogisVert | $3,000AHRI 217512785 | $3,000AHRI 213927543 | On quotationAHRI on product page: 8950554 |
| Availability | Coming soon to AirGreen | In the catalogue | In the catalogue |
| Product pages | Dual-zone | Dual-zone | Dual-zone |
Sources: ENERGY STAR (Oct. 8, 2026), Sharp spec sheets and capacity table, Hydro-Québec LogisVert tool (Oct. 6, 2026), NEEP (Oct. 8, 2026). The TU dual-zone (R-410A, down to -20°C according to Sharp) is neither ENERGY STAR certified nor on the NEEP list.
The CU holds to -30°C, the BU to -27°C, the TU to -20°C.
-8°C and -15°C: ENERGY STAR; -30°C: Sharp, with three 12,000 heads. Montreal temperatures: MétéoMédia (2021 and 2025) and 1871-2024 records.
Draw your lines: up to 25 m per room, 70 m in total.
Beyond what Sharp plans for: we rethink the location at the visit.
Limits with added refrigerant, according to Sharp (AE-X3M24CU). We measure the real route at your place.
At -15°C, 1 kWh of electricity gives 2.3 of heat.
According to ENERGY STAR, for the CU and BU multi-zones. The TU dual-zone isn’t certified.
1 kWh of electricity at -15°C: how much heat?
Electric baseboards: 1 kWh of heat for 1 kWh of electricity · ENERGY STAR cold-climate bar: 1.75
Coefficient of performance (COP) at -15°C according to ENERGY STAR. An electric baseboard turns all its electricity into heat, no more: its COP is 1. For cold-climate certification, ENERGY STAR requires at least 1.75 at this temperature.
Tap a card to flip it.
Japanese engineering, a local team.
Sharp decides how the heat is shared. We decide where the heads go so each room gets its share.
What SHARP brings
- Down to -30°CThe CU multi-zone, according to Sharp’s January 2026 spec sheet.
- Two or three roomsCU heads of 9,000, 12,000 or 18,000 BTU/h; with three rooms, 9,000 or 12,000.
- ENERGY STARCU and BU multi-zone systems certified as of October 8, 2026.
- CHU units stay singleAccording to Sharp, CHU units don’t go on a multi-zone.
What AirGreen brings
- SHARP Platinum dealerOn Sharp’s official dealer list for Quebec.
- Free home estimateWe look at the room, the wall and the outdoor location.
- Full commissioningAnd SHARP AIR app setup at installation.
- RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.
The result: a dual-zone chosen for your two rooms, installed by a Platinum team.
$3,000 for a CU or BU multi-zone, checked with Hydro-Québec.
We looked up every AHRI number on our product pages in Hydro-Québec’s tool on October 6, 2026. Every Sharp on the list is rated cold climate: $120 per 1,000 BTU/h of heat at -8°C.
| Sharp system | AHRI | Heat at -8°C | LogisVert |
|---|---|---|---|
| CU multi-zone · 2 or 3 roomsAE-X3M24CU | 217512785 | 25,000 BTU/h | $3,000 |
| BU multi-zone · 2 or 3 roomsAE-X3M24BU, previous generation | 213927543 | 25,000 BTU/h | $3,000 |
Since November 26, 2025, only an ENERGY STAR certified system is eligible.
The outdoor unit must have a rated capacity of at least 12,000 BTU/h.
The grant never exceeds 100% of the pre-tax cost.
Deadline to apply: 9 months after installation (LogisVert guide, version 1.10).
25,000 BTU/h at -8°C × $120 per 1,000 BTU/h = $3,000
AHRI 217512785
For a cold-climate heat pump on Hydro-Québec’s list. Indicative amount: Hydro-Québec confirms it when it reviews your application, which must be filed no later than 9 months after installation.
Indicative amounts: Hydro-Québec confirms the grant when you apply. The multi-unit building bonus only applies to certain eligible buildings and is not included here.
The Sharp warranty, as Sharp writes it.
Sharp consumer limited warranty (U.S. and Canada), Airest and ZU / ZHU / BU manuals, read Oct. 6, 2026. Warrantor: Sharp Corporation.
For CHU, CU and FilterSweep, Sharp has not yet published the warranty text in its manuals (product registration announced as “coming soon”). We give you the exact terms with the quotation.
The Sharp manuals checked for this page cover the Airest and the ZU, ZHU and BU, not the TU and THU (R-410A). We give you your unit’s warranty terms with the quotation.
Good to know
- The years count from the installation date.
- Keep your proof of purchase and installation date: Sharp asks for them.
- Filters, accessories and cosmetic parts are not covered.
- A unit moved from its original installation site loses the warranty.
- Warrantor: Sharp Corporation; contact in Canada: Sharp Electronics of Canada.
- Keep your proof of purchase and installation date.
- We confirm the terms in writing, before you buy.

SHARP Platinum dealer: what it means for you.
Two rooms, one visit. AirGreen is on Sharp’s official dealer list for Quebec.
Access to the CHU, CU, FilterSweep, Airest, ZU1 and ZHU1 series and to Sharp multi-zone systems.
Installation, Wi-Fi setup with the SHARP AIR app, Plasmacluster ion settings, diagnostics and repairs.
Professional vacuum pull, refrigerant parameters validated, performance checked for winter.
Sharp parts through Sharp’s Canadian distributor; after-sales service in Montreal, Laval, Longueuil, the North Shore, the South Shore and Montérégie.
We look at the room, the wall and the outdoor location.
Series, size, colour, and the indicative LogisVert amount with its AHRI number.
Full commissioning and SHARP AIR app setup.
We stay your contact for the Sharp warranty and maintenance.
A BU multi-zone on our job sites.
A short clip shot during one of our installations.
79 published Sharp multi-zone installations since 2023.
Including 73 BU.
By series named in the article
Articles published on our blog as of October 6, 2026. These are published articles, not a count of jobs.
What people ask us about the Sharp dual-zone.
With the CU multi-zone, Sharp plans for every pair of CU heads of 9,000, 12,000 and 18,000 BTU/h. Rated system heating ranges from 20,200 to 26,000 BTU/h according to Sharp’s table.
$3,000 for the CU multi-zone (AHRI 217512785) and for the BU (AHRI 213927543), according to Hydro-Québec’s tool, checked on October 6, 2026. The TU dual-zone is not on the list.
It’s coming soon to AirGreen. The BU, the previous generation, is in the catalogue in dual- and triple-zone.
No. According to the Sharp CU/CHU manual, CHU units don’t connect to a multi-zone system. For several rooms on one outdoor unit, look at the CU multi-zone.
In the ZU, ZHU and BU manual, Sharp warrants the compressor for 7 years and other parts for 6 years, from installation. For the CU multi-zone and the TU dual-zone, we give you the exact terms with the quotation.
According to Sharp’s table, two 9,000 heads give the system 20,200 BTU/h of rated heat, the lowest of all pairs; 12,000 + 9,000 give 23,400; the other pairs, 26,000. We choose based on your two rooms.
According to Sharp, up to 25 m per head and 70 m in total for the CU multi-zone, with added refrigerant. We measure the real route at the free visit.
Yes, with the CU dual-zone, coming soon to AirGreen: the CU 18,000 head comes in dark grey (AY-XPC18CU-B) and connects to it, according to Sharp.

Your Sharp dual-zone, installed by AirGreen.
We visit your two rooms, route the lines and write down the combination with its LogisVert amount. Montreal, Laval, Longueuil, South Shore, North Shore.
Hydro-Québec never solicits anyone by phone or door to door for LogisVert. A call “from Hydro-Québec” selling a heat pump? Hang up.
Sources checked on October 6 and 8, 2026
- Sharp submittal sheets: CHU and CU (January 2026), FilterSweep AY-XP12DWU (May 2026), Airest (June 2025), AE-X3M24CU multi-zone (January 2026) and its capacity table.
- ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, queried by AHRI number on Oct. 8, 2026 (heat at 17°F and 5°F, SEER2, EER2, HSPF2, COP).
- NEEP cold-climate heat pump list (ashp.neep.org), search by AHRI number on Oct. 8, 2026: no listing for the older ZU, ZHU 12,000, ZHU1 18,000, TU, THU and TU dual-zone models.
- Sharp HVAC, CHU / CU product page (air throw, motion sensor, After Care, line lengths, finishes, sound levels), re-read Oct. 8, 2026.
- Sharp owner’s manuals OM_CU_CHU, OM_CPU and OM_ZU_ZHU_BU (limited warranty, Plasmacluster ions, After Care and self-cleaning).
- Hydro-Québec, LogisVert residential participation guide, version 1.10, Sept. 15, 2026.
- Hydro-Québec, eligible heat pump search tool (search by AHRI number), checked Oct. 6, 2026.
- ENERGY STAR heat pump criteria, Version 6.2 (rev. February 2026): cold climate, COP of at least 1.75 at 5°F (-15°C).
- MétéoMédia, January 25, 2021: -30°C or colder in Montreal, 34 times since 1941; the last on January 27, 1994 (-31.8°C).
- MétéoMédia, January 31, 2025: -29.5°C in Montreal on February 4, 2023.
- Montreal records 1871-2024 (Extreme Weather Watch): record low of -37.8°C on January 15, 1957.
- AirGreen, installations blog, articles published as of Oct. 6, 2026; airgreen.ca product pages, Oct. 8, 2026.
LogisVert amounts are indicative: Hydro-Québec confirms them when you apply.
Our Sharp dual-zone systems, right below.
With their full product page and AHRI number.