Multi-zone heat pump, 4 zones: FORESTAIR FA-M36 or FA-M42?
With four heads, the FA-M36 is at its maximum; the FA-M42, with the same 1,074 × 853 × 468 mm outer dimensions, allows five. NEEP lists 30,000 BTU/h at −15 °C for the FA-M42’s non-ducted combination, against 26,000 for the FA-M36’s, and its submittal takes a breaker of up to 45 A, against 35 A. For three rooms: our three-head systems.
Multi-zone, 4 zones: the 2 systems in the shop
One on the FA-M36, the other on the FA-M42, each with four wall heads.
FA-M36 or FA-M42 for 4 heads: deep cold, weight, breaker, LogisVert
Pick a criterion: the difference between the two units, each one’s value and its source. For deep cold, the figures come from NEEP, the list of cold-climate heat pumps; at −25 °C, it gives only a maximum: 19,000 BTU/h for the FA-M36, 23,000 for the FA-M42.
Difference: the FA-M42’s value minus the FA-M36’s (our calculation). Heating capacity: NEEP records 508677 (FA-M36) and 508676 (FA-M42), “Multizone All Non-Ducted”, read November 5, 2026. NEEP gives neither the number nor the size of the heads in the listed combination; your system’s capacity depends on the heads chosen. Cooling, weight and breaker: FA-M36-D4TL/O and FA-M42-D5TL/O submittals (footer 112025). LogisVert: amounts from our product pages. Indicative amount. Only Hydro-Québec confirms the assistance granted.
Non-ducted combinations listed on NEEP · −15 °C
+4,000BTU/h difference in the FA-M42’s favour (our calculation)
FA-M36 and FA-M42: current, kW in deep cold and maximum cooling
the electricity NEEP lists at −15 °C for the FA-M36 and FA-M42, at nominal output
For their non-ducted combinations, NEEP lists an electrical input at −15 °C of 3.81 kW for the FA-M36 and 4.40 kW for the FA-M42, with the same COP of 2.00: at that temperature, each returns two units of heat for one unit of electricity.
NEEP records 508677 and 508676 (kW column), read November 5, 2026.the FA-M36 draws more current in cooling than in heating, at nominal output
Submittals, on 208-230 V: FA-M36, 13.1 A in cooling and 12.0 A in heating; FA-M42, 15.9 A and 14.6 A.
FA-M36-D4TL/O and FA-M42-D5TL/O submittals: Electrical Data.BTU/h of maximum cooling at 35 °C, listed on NEEP for the FA-M36 and FA-M42
For their non-ducted combinations, NEEP lists in cooling at 35 °C a nominal value of 35,000 BTU/h and a maximum of 37,500 BTU/h for the FA-M36; 42,000 and 46,000 BTU/h for the FA-M42.
NEEP records 508677 and 508676, read November 5, 2026.FA-M36 and FA-M42: what stays the same
On the lines below, the two units have the same value in their submittals.
| For both | FA-M36 and FA-M42 |
|---|---|
| Outer dimensions, W × H × D | 1,074 × 853 × 468 mm |
| Mounting dimensions A × B (dimensions table) | 660 × 462 mm |
| Outdoor airflow | 3,200 m³/h |
| Outdoor sound (sound pressure) | 65 dB(A) |
FA-M36 or FA-M42: what we check before choosing
- The fourth line: on the FA-M36, your four lines share 80 m, an average of 20 m each (our calculation); the FA-M42 leaves 90.
- The FA-M36’s supply wiring: 22 A at least, its submittal’s MCA; the FA-M42 calls for 28.
FORESTAIR multi-zone, 4 zones: common questions
Does the FA-M36 cool at 36,000 BTU/h?
Its submittal publishes 35,000 BTU/h in nominal cooling and 36,000 BTU/h in nominal heating. The ENERGY STAR registry (record 4529625) and NEEP (508677) also list 35,000 BTU/h in cooling.
Is the smaller FA-M36 quieter outside?
Not per its submittal: 65 dB(A) of sound pressure, with no measuring distance, exactly like the FA-M42, with the same outdoor airflow of 3,200 m³/h. The FA-M27 publishes 62 dB(A), but its submittal stops at three heads. Québec.ca reference points: 40 dB(A) is perceived as peaceful; 50 dB(A) is where noise starts to disturb.
Which one is more efficient in cooling?
Per their submittals, the FA-M36 publishes a SEER2 of 22.5 and an EER2 of 11.1; the FA-M42, 22.0 and 11.2. A SEER2 of 22.5 against 22.0 means slightly less electricity over a cooling season for the FA-M36. The gap is half a point on SEER2 and a tenth on EER2, in opposite directions (our calculation).
Do the FA-M36 figures change with ducted units?
Its NEEP and ENERGY STAR figures, yes; its lines, weight and breaker do not change: they are on the same submittal. That submittal carries a second AHRI number, 217512367, for the ducted combination, which NEEP lists separately (508673). That record contradicts itself: at −8.3 °C, its nominal value of 30,000 BTU/h is above its listed maximum of 26,500 BTU/h. We quote it as listed, without correcting it.
How much LogisVert assistance for a 4-zone FORESTAIR system?
FA-M36: $3,288; FA-M42: $3,720, indicative amount each, from our product pages. The calculation, unit by unit: FA-M36, 27,400 BTU/h listed on NEEP at −8.3 °C × $120 per 1,000 BTU/h = $3,288; FA-M42, 31,000 BTU/h × $120 per 1,000 BTU/h = $3,720. The rate is the LogisVert guide v1.10 rate, stated at −8 °C, for an ENERGY STAR “cold climate” heat pump; the NEEP list is not the LogisVert list, which requires ENERGY STAR. Only Hydro-Québec confirms the assistance granted.
Before the visit: your panel and the space outside
- Room in your panel: 35 A at most for the FA-M36, 45 A for the FA-M42.
- Where the outdoor unit goes: 1,074 × 853 × 468 mm, 66 or 79 kg.
Hydro-Québec never solicits by phone or door to door for the LogisVert Efficient Homes Program.
Sources
- FORESTAIR, submittal data FA-M36-D4TL/O, “Multizone Series Condensing Unit”, footer 112025, © FORESTAIR 2025. PDF
- FORESTAIR, submittal data FA-M42-D5TL/O, “Multizone Series Condensing Unit”, footer 112025, © FORESTAIR 2025. PDF
- NEEP, Cold Climate Air Source Heat Pump List, records 508677, 508676 and 508673, read November 5, 2026. ashp.neep.org
- ENERGY STAR, heat pump registry, Canadian market (dataset w7cv-9xjt), record 4529625, read November 5, 2026. data.energystar.gov
- Hydro-Québec, LogisVert Efficient Homes Program, participant’s guide, version 1.10 (September 15, 2026). Indicative amounts: those on our product pages. hydroquebec.com
- Government of Québec, “Noise measurement”, updated June 16, 2022. quebec.ca
Page updated November 11, 2026.