Multi-zone, 4 heads · FORESTAIR

Multi-zone heat pump, 4 zones: FORESTAIR FA-M36 or FA-M42?

With four heads, the FA-M36 is at its maximum; the FA-M42, with the same 1,074 × 853 × 468 mm outer dimensions, allows five. NEEP lists 30,000 BTU/h at −15 °C for the FA-M42’s non-ducted combination, against 26,000 for the FA-M36’s, and its submittal takes a breaker of up to 45 A, against 35 A. For three rooms: our three-head systems.

2four-head systems: one on the FA-M36, one on the FA-M42
45 Abreaker at most for the FA-M42; 35 A for the FA-M36submittals
79 kgnet weight of the FA-M42; 66 kg for the FA-M36submittals
4 · 5indoor units at most: FA-M36, then FA-M42submittals
FA-M36 · up to 4 headsFA-M42 · up to 5 headsSame outer dimensions
The shop

Multi-zone, 4 zones: the 2 systems in the shop

One on the FA-M36, the other on the FA-M42, each with four wall heads.

FORESTAIR
M36 or M42

FA-M36 or FA-M42 for 4 heads: deep cold, weight, breaker, LogisVert

Pick a criterion: the difference between the two units, each one’s value and its source. For deep cold, the figures come from NEEP, the list of cold-climate heat pumps; at −25 °C, it gives only a maximum: 19,000 BTU/h for the FA-M36, 23,000 for the FA-M42.

FORESTAIR
Criterion

Difference: the FA-M42’s value minus the FA-M36’s (our calculation). Heating capacity: NEEP records 508677 (FA-M36) and 508676 (FA-M42), “Multizone All Non-Ducted”, read November 5, 2026. NEEP gives neither the number nor the size of the heads in the listed combination; your system’s capacity depends on the heads chosen. Cooling, weight and breaker: FA-M36-D4TL/O and FA-M42-D5TL/O submittals (footer 112025). LogisVert: amounts from our product pages. Indicative amount. Only Hydro-Québec confirms the assistance granted.

Non-ducted combinations listed on NEEP · −15 °C

+4,000BTU/h difference in the FA-M42’s favour (our calculation)

FA-M3626,000 BTU/h
FA-M4230,000 BTU/h
SourceNEEP, records 508677 and 508676
Did you know?

FA-M36 and FA-M42: current, kW in deep cold and maximum cooling

FORESTAIR
3.81 · 4.40 kW

the electricity NEEP lists at −15 °C for the FA-M36 and FA-M42, at nominal output

For their non-ducted combinations, NEEP lists an electrical input at −15 °C of 3.81 kW for the FA-M36 and 4.40 kW for the FA-M42, with the same COP of 2.00: at that temperature, each returns two units of heat for one unit of electricity.

NEEP records 508677 and 508676 (kW column), read November 5, 2026.
13.1 A vs 12.0 A

the FA-M36 draws more current in cooling than in heating, at nominal output

Submittals, on 208-230 V: FA-M36, 13.1 A in cooling and 12.0 A in heating; FA-M42, 15.9 A and 14.6 A.

FA-M36-D4TL/O and FA-M42-D5TL/O submittals: Electrical Data.
37,500 · 46,000

BTU/h of maximum cooling at 35 °C, listed on NEEP for the FA-M36 and FA-M42

For their non-ducted combinations, NEEP lists in cooling at 35 °C a nominal value of 35,000 BTU/h and a maximum of 37,500 BTU/h for the FA-M36; 42,000 and 46,000 BTU/h for the FA-M42.

NEEP records 508677 and 508676, read November 5, 2026.
The comparison that matters

FA-M36 and FA-M42: what stays the same

On the lines below, the two units have the same value in their submittals.

FORESTAIR
For bothFA-M36 and FA-M42
Outer dimensions, W × H × D1,074 × 853 × 468 mm
Mounting dimensions A × B (dimensions table)660 × 462 mm
Outdoor airflow3,200 m³/h
Outdoor sound (sound pressure)65 dB(A)
FA-M36-D4TL/O and FA-M42-D5TL/O submittals (footer 112025). Sound: the submittals’ sound pressure, with no measuring distance. Québec.ca reference points: 40 dB(A) is perceived as peaceful; 50 dB(A) is where noise starts to disturb. Five heads on the FA-M42
What we check in your home

FA-M36 or FA-M42: what we check before choosing

FORESTAIR
  • The fourth line: on the FA-M36, your four lines share 80 m, an average of 20 m each (our calculation); the FA-M42 leaves 90.
  • The FA-M36’s supply wiring: 22 A at least, its submittal’s MCA; the FA-M42 calls for 28.
Frequently asked questions

FORESTAIR multi-zone, 4 zones: common questions

FORESTAIR
Does the FA-M36 cool at 36,000 BTU/h?

Its submittal publishes 35,000 BTU/h in nominal cooling and 36,000 BTU/h in nominal heating. The ENERGY STAR registry (record 4529625) and NEEP (508677) also list 35,000 BTU/h in cooling.

Is the smaller FA-M36 quieter outside?

Not per its submittal: 65 dB(A) of sound pressure, with no measuring distance, exactly like the FA-M42, with the same outdoor airflow of 3,200 m³/h. The FA-M27 publishes 62 dB(A), but its submittal stops at three heads. Québec.ca reference points: 40 dB(A) is perceived as peaceful; 50 dB(A) is where noise starts to disturb.

Which one is more efficient in cooling?

Per their submittals, the FA-M36 publishes a SEER2 of 22.5 and an EER2 of 11.1; the FA-M42, 22.0 and 11.2. A SEER2 of 22.5 against 22.0 means slightly less electricity over a cooling season for the FA-M36. The gap is half a point on SEER2 and a tenth on EER2, in opposite directions (our calculation).

Do the FA-M36 figures change with ducted units?

Its NEEP and ENERGY STAR figures, yes; its lines, weight and breaker do not change: they are on the same submittal. That submittal carries a second AHRI number, 217512367, for the ducted combination, which NEEP lists separately (508673). That record contradicts itself: at −8.3 °C, its nominal value of 30,000 BTU/h is above its listed maximum of 26,500 BTU/h. We quote it as listed, without correcting it.

How much LogisVert assistance for a 4-zone FORESTAIR system?

FA-M36: $3,288; FA-M42: $3,720, indicative amount each, from our product pages. The calculation, unit by unit: FA-M36, 27,400 BTU/h listed on NEEP at −8.3 °C × $120 per 1,000 BTU/h = $3,288; FA-M42, 31,000 BTU/h × $120 per 1,000 BTU/h = $3,720. The rate is the LogisVert guide v1.10 rate, stated at −8 °C, for an ENERGY STAR “cold climate” heat pump; the NEEP list is not the LogisVert list, which requires ENERGY STAR. Only Hydro-Québec confirms the assistance granted.

Sold and installed by AirGreen.

Before the visit: your panel and the space outside

  • Room in your panel: 35 A at most for the FA-M36, 45 A for the FA-M42.
  • Where the outdoor unit goes: 1,074 × 853 × 468 mm, 66 or 79 kg.
RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16. Gas and oil: a licensed partner.
Free estimateAt home, no commitment.
LogisVert on the quoteAHRI number and indicative amount when the unit qualifies. Only Hydro-Québec confirms the assistance granted.
Showroom1370 Joliot-Curie Street, Suite 712, Boucherville.

Hydro-Québec never solicits by phone or door to door for the LogisVert Efficient Homes Program.

AirGreenFORESTAIR

Sources

  1. FORESTAIR, submittal data FA-M36-D4TL/O, “Multizone Series Condensing Unit”, footer 112025, © FORESTAIR 2025. PDF
  2. FORESTAIR, submittal data FA-M42-D5TL/O, “Multizone Series Condensing Unit”, footer 112025, © FORESTAIR 2025. PDF
  3. NEEP, Cold Climate Air Source Heat Pump List, records 508677, 508676 and 508673, read November 5, 2026. ashp.neep.org
  4. ENERGY STAR, heat pump registry, Canadian market (dataset w7cv-9xjt), record 4529625, read November 5, 2026. data.energystar.gov
  5. Hydro-Québec, LogisVert Efficient Homes Program, participant’s guide, version 1.10 (September 15, 2026). Indicative amounts: those on our product pages. hydroquebec.com
  6. Government of Québec, “Noise measurement”, updated June 16, 2022. quebec.ca

Page updated November 11, 2026.