MIDEA EVOX G3 and GREE FLEXX ULTRA, 2 tons

Comparison · Central heat pump · 2 tons

MIDEA EVOX G3 and GREE FLEXX ULTRA R32, 2 tons

Two 24,000 BTU/h central heat pumps, for a small house or a well-insulated home. At this size, the question is not only how much each one can deliver, but how low it can go.

GREE FLEXX ULTRA R32, AirGreen product card GREE

FLEXX ULTRA R32 · 2 tons

FXU24HP230V1R32AH + FXU24HP230V1R32AO · AHRI 215213329 See the product page
Lowest certified output at 8.3 °C, BTU/h6,600and10,800
SEER2 (AHRI certificate)18.6and18
HSPF2 Region V8.1and7.6
Certified max. heating at −30 °C, BTU/h12,100and18,000
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 24,000 BTU/h house in Montréal, on Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the benchmark.

How this amount is calculated
  1. Heat needed over the winter. A house whose heat loss reaches 24,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: a simplification that ignores the recovery after a setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup planned for when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 24,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. The network access fee, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.

The small house

Your house against each heat pump's range

Set the house's heat loss at −23.1 °C. The yellow line shows what it asks for at each certified temperature; the bands run from the lowest to the highest output each certificate publishes at that temperature.

20,000BTU/h
10,00036,000

A heat loss of 20,000 BTU/h at −23.1 °C gives 4,720 BTU/h at 8.3 °C.

A house's heat loss is calculated room by room by an estimator; the slider is there to show the effect of a value.

Method: the demand at each temperature is proportional to the gap with 18 °C, the same base as the cost calculation (load × (18 − T) ÷ 41.1). Below the lowest certified output, a variable-speed heat pump can no longer slow down: it stops and restarts. Above the highest, the electric backup supplies the rest. Outputs: AHRI certificates published by NEEP, records 387399 and 504980.

Extreme cold

What each one publishes below −15 °C, at 2 tons

NEEP measures both systems at the same temperatures, including −30 °C. Between −15 and −30 °C, GREE also publishes a capacity table for the 24,000 BTU/h FLEXX ULTRA. Each value is placed at its own temperature, with its source; nothing is calculated between two points.

The GREE table (Extended Ratings, August 27, 2024) gives total capacity with 21.1 °C indoors; it does not say whether this is maximum output. At −15 °C it gives 24,000 BTU/h, and the certificate 25,000 BTU/h maximum: the page shows both.

Features

The features of a 2-ton system, document by document

Only what appears in the submittal sheets of the two 24,000 BTU/h systems. A feature missing from a document is not necessarily missing from the unit.

Thermostat and control

MIDEA: 120N (X6W) wired controller with built-in Wi-Fi, wireless remote, or a third-party 24 V thermostat.

GREE: compatible with a 24 V AC thermostat.

Submittals MAUSE-H24B-2A / MO1HE-H24B-2A and GREE_FXU24_230V_R32_SUB_05162025
Wi-Fi and app

MIDEA: through the 120N (X6W) wired controller, built-in Wi-Fi.

GREE: not stated in the 2-ton submittal sheet.

Same sheets
Electric backup heat

MIDEA: optional electric heat kit, up to 25 kW.

GREE: optional FLEXA2LHTR06 kit: 4.5 kW at 208 V, 5.5 kW at 230 V.

Same sheets
Heated base pan

MIDEA: base pan heater standard; NEEP lists 150 W.

GREE: base pan with heating element; NEEP lists 160 W.

Submittal sheets · NEEP records 387399 and 504980
Compressor

MIDEA: rotary KTM240D46UKT2, with standard crankcase heater.

GREE: compressor with heating element.

Same sheets
Indoor fan airflow

MIDEA: 5 speeds, from 630 to 824 cfm; static pressure 0 to 1.0 in. w.c.

GREE: 5 speeds; 760 cfm at 1.0 in. w.c.

Same sheets
Sound

A small system is heard mostly at low speed

MIDEA publishes its 2-ton air handler at 33 dB(A) on low speed and 47.5 dB(A) at its loudest; GREE gives one sound pressure value for its own, 50 dB(A). Outdoors: 59 dB(A) for the MIDEA, 60 dB(A) for the GREE. Neither sheet gives the measuring distance.

dB(A)

How to read these numbers. dB(A) measures a noise level as the ear perceives it: the lower the number, the quieter the unit. Each dot is a published value.

Why this is not a ranking. Neither manufacturer states its measuring conditions; different method, not comparable to the decibel.

Air handler, inside the house

Published values

Outdoor unit

Published values

In a small house, the system spends much of the winter at the bottom of its range (see “The small house”): the low-speed value is the one that matters day to day. Each manufacturer measures its own way; these values are reference points, not a ranking.

Installation

Two very different sizes for the same output

Outdoor units, to the same scale

Outdoor unit MIDEA MO1HE-H24B-2A
MO1HE-H24B-2A35 × 26 1/2 in · 102 lb
Outdoor unit GREE FXU24HP230V1R32AO
FXU24HP230V1R32AO39 × 37 13/16 in · 187.4 lb

Photos from the 2-ton submittal sheets, to the same scale: the MO1HE-H24B-2A, low and wide, stands 26 1/2 in tall; the FXU24 stands 37 13/16 in.

Air handlers, to the same scale

Air handler MIDEA MAUSE, series image
MAUSE-H24B-2A14 1/2 × 53 7/8 in · 123 lb
Air handler GREE FLEXX ULTRA, series image
FXU24HP230V1R32AH18 1/8 × 43 1/2 in · 135.6 lb

Series images of the air handlers, to the same scale: 53 7/8 in tall for the MAUSE-H24B-2A, 43 1/2 in for the FXU24HP230V1R32AH.

Line length between the two units

40 ft
covered by the factory chargerefrigerant addedoutside the published limits
InstallationEVOX G3 · 2 tonsFLEXX ULTRA R32 · 2 tons
Maximum piping lengthNot stated on the 2-ton submittal sheet164 ftminimum 10 ft
Pre-charged length25 ft (7.5 m)0.7 oz per ft beyond31 ft0.323 oz per ft beyond
Maximum height difference82 ft (25 m)98 ft
Liquid – gas diameters3/8 – 3/4 in, flare connections3/8 – 3/4 in, flare connections
Refrigerant, factory chargeR-454B, 74 oz (2.1 kg)R-32, 88.2 oz
Outdoor unit W × H × D, weight35 × 26 1/2 × 13 1/2 in, 102 lb39 × 37 13/16 × 14 9/16 in, 187.4 lb
Indoor unit W × H × D, weight14 1/2 × 53 7/8 × 21 1/2 in, 123 lb18 1/8 × 43 1/2 × 21 1/4 in, 135.6 lb
Electrical protectionOutdoor: MCA 19 A, MOP 20 A; indoor: MCA 3.5 A, MOP 15 A208/230 VOutdoor: MCA 21 A, MOCP 25 A; indoor: MCA 4.7 A, MOCP 15 A208-230 V
Indoor fan airflow5 speeds: 824, 759, 694, 630 and 630 cfm5 speeds; 760 cfm at 1.0 in. w.c.
Published heating / cooling range−30 to 24 °C / −30 to 50 °C−30 to 24 °Clow heating limit: −22 °F

Sources: MIDEA submittal sheet MAUSE-H24B-2A / MO1HE-H24B-2A (undated); GREE submittal sheet GREE_FXU24_230V_R32_SUB_05162025. The GREE sheet also shows a depth of 29 3/4 in on its drawing, without explanation; the page follows its specification table. Calculating a home's electrical service is a job for a master electrician.

Questions

What people ask us about these two 2-ton systems

Why talk about the lowest output?

A well-insulated house asks for little heat for most of the winter. When demand drops below the lowest certified output, the heat pump stops and restarts instead of slowing down. At 8.3 °C, the EVOX G3 certificate gives 6,600 BTU/h minimum, the FLEXX ULTRA certificate 10,800 BTU/h.

And in extreme cold?

At −30 °C, both certificates give a maximum output: 12,100 BTU/h for the EVOX G3, 18,000 BTU/h for the FLEXX ULTRA. Beyond what it delivers, the electric backup takes over. The slider in “The small house” shows the heat loss at which that happens.

Is the 2-ton just a smaller 3-ton?

No. Each size has its own AHRI certificate: 215471340 (EVOX G3) and 215213329 (FLEXX ULTRA) for the 2-ton. At MIDEA, the 2-ton outdoor unit (MO1HE-H24B-2A, 35 × 26 1/2 in) is smaller than the one in the 3-ton sold by AirGreen (MO1SE-H36B-2A, 38 9/16 × 38 3/8 in). The 3-ton comparison has its own page.

Why is the GREE outdoor unit so much bigger?

GREE publishes the same outdoor dimensions for the 2-ton and 3-ton FLEXX ULTRA (39 × 37 13/16 × 14 9/16 in, 187.4 lb). MIDEA publishes 35 × 26 1/2 × 13 1/2 in and 102 lb for the 2-ton EVOX G3. Plan the space and the support accordingly.

Are both ENERGY STAR certified?

The NEEP records of both certificates show ENERGY STAR and the cold-climate criterion.

Do they use the same refrigerant?

No: R-454B for the EVOX G3 (GWP 466, IPCC AR4) and R-32 for the FLEXX ULTRA (GWP 675, IPCC AR4), both class A2L under ASHRAE 34.

Certified sheet

The certificate values, side by side

Certified valueEVOX G3 · 2 tonsFLEXX ULTRA R32 · 2 tons
Certificate
AHRI certificate · NEEP record215471340 · 387399MAUSE-H24B-2A + MO1HE-H24B-2A215213329 · 504980FXU24HP230V1R32AH + FXU24HP230V1R32AO
ENERGY STAR (NEEP record)Yes, cold-climate criterion includedYes, cold-climate criterion included
RefrigerantR-454B · GWP 466 (IPCC AR4) · class A2LR-32 · GWP 675 (IPCC AR4) · class A2L
Seasonal efficiency
SEER218.618
EER21212
HSPF2 Region IV1010
HSPF2 Region V8.17.6
Certified heating, BTU/h
Min. / rated / max. capacity at 8.3 °C6,600 / 24,000 / 29,20010,800 / 25,000 / 25,400
Min. / rated / max. capacity at −8.3 °C4,900 / 20,800 / 20,8007,100 / 20,600 / 21,600
Min. / rated / max. capacity at −15 °C5,300 / 20,600 / 20,60014,000 / 25,000 / 25,000
COP at 8.3 °C (lowest, rated, highest output)4.84 / 3.50 / 3.495.11 / 3.59 / 3.56
COP at −15 °C (lowest, rated, highest output)2.07 / 2.14 / 2.142.55 / 2.00 / 2.00
Coldest certified point
Test temperature−30 °C (−22 °F)−30 °C (−22 °F)
Capacity at the coldest point (lowest / highest)2,500 / 12,100 BTU/h13,400 / 18,000 BTU/h
COP at the coldest point (lowest / highest output)1.08 / 1.401.37 / 1.36
Cooling
Rated capacity at 35 °C24,000 BTU/hmin. 6,400, max. 28,80024,000 BTU/hmin. 11,200, max. 24,000

“higher” marks the higher value of the same measure, under the same conditions. It is not a recommendation. At the coldest point, both are measured at −30 °C: the values compare directly, but this group is not highlighted.

Both are on the AirGreen website.

To choose for your home, talk it over with our team: bring the heated area, the condition of the ducts, the space planned for the outdoor unit and your current heating.

Sources

Documents reviewed

NEEP, record 387399 (EVOX G3, 2 tons)AHRI 215471340 · reviewed November 10, 2026
NEEP, record 504980 (FLEXX ULTRA R32, 2 tons)AHRI 215213329 · reviewed November 10, 2026
MIDEA, submittal sheet MAUSE-H24B-2A / MO1HE-H24B-2AExtreme Heat AHU series, undated · reviewed November 10, 2026
GREE, submittal sheet FXU24 (R32)GREE_FXU24_230V_R32_SUB_05162025 · copy hosted by a distributor · reviewed November 10, 2026
GREE, FLEXX ULTRA R32 Extended RatingsCAT NO GREE_FLEXX_ULTRA_EXTENDED RATINGS_08272024 · heating, FXU24, 21.1 °C indoors · reviewed November 10, 2026
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5 · these rates may change
NRCan, HOT2000 climate mapMontréal Intl: 4,167 degree-days (base 18 °C), design temperature −23.1 °C