MIDEA EVOX G3 and GREE FLEXX ULTRA R32, 2 tons
Two 24,000 BTU/h central heat pumps, for a small house or a well-insulated home. At this size, the question is not only how much each one can deliver, but how low it can go.
MIDEA
EVOX G3 · 2 tons
MAUSE-H24B-2A + MO1HE-H24B-2A · AHRI 215471340 See the product page
GREE
FLEXX ULTRA R32 · 2 tons
FXU24HP230V1R32AH + FXU24HP230V1R32AO · AHRI 215213329 See the product pageWhat the electricity costs, in dollars, winter and summer
AirGreen estimate for the same 24,000 BTU/h house in Montréal, on Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the benchmark.
How this amount is calculated
- Heat needed over the winter. A house whose heat loss reaches 24,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: a simplification that ignores the recovery after a setback.
- Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup planned for when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
- Electricity for cooling. 24,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
- Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. The network access fee, the same with or without a heat pump, is not counted.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.
Your house against each heat pump's range
Set the house's heat loss at −23.1 °C. The yellow line shows what it asks for at each certified temperature; the bands run from the lowest to the highest output each certificate publishes at that temperature.
A heat loss of 20,000 BTU/h at −23.1 °C gives 4,720 BTU/h at 8.3 °C.
A house's heat loss is calculated room by room by an estimator; the slider is there to show the effect of a value.
Method: the demand at each temperature is proportional to the gap with 18 °C, the same base as the cost calculation (load × (18 − T) ÷ 41.1). Below the lowest certified output, a variable-speed heat pump can no longer slow down: it stops and restarts. Above the highest, the electric backup supplies the rest. Outputs: AHRI certificates published by NEEP, records 387399 and 504980.
What each one publishes below −15 °C, at 2 tons
NEEP measures both systems at the same temperatures, including −30 °C. Between −15 and −30 °C, GREE also publishes a capacity table for the 24,000 BTU/h FLEXX ULTRA. Each value is placed at its own temperature, with its source; nothing is calculated between two points.
The GREE table (Extended Ratings, August 27, 2024) gives total capacity with 21.1 °C indoors; it does not say whether this is maximum output. At −15 °C it gives 24,000 BTU/h, and the certificate 25,000 BTU/h maximum: the page shows both.
The features of a 2-ton system, document by document
Only what appears in the submittal sheets of the two 24,000 BTU/h systems. A feature missing from a document is not necessarily missing from the unit.
MIDEA: 120N (X6W) wired controller with built-in Wi-Fi, wireless remote, or a third-party 24 V thermostat.
GREE: compatible with a 24 V AC thermostat.
Submittals MAUSE-H24B-2A / MO1HE-H24B-2A and GREE_FXU24_230V_R32_SUB_05162025MIDEA: through the 120N (X6W) wired controller, built-in Wi-Fi.
GREE: not stated in the 2-ton submittal sheet.
Same sheetsMIDEA: optional electric heat kit, up to 25 kW.
GREE: optional FLEXA2LHTR06 kit: 4.5 kW at 208 V, 5.5 kW at 230 V.
Same sheetsMIDEA: base pan heater standard; NEEP lists 150 W.
GREE: base pan with heating element; NEEP lists 160 W.
Submittal sheets · NEEP records 387399 and 504980MIDEA: rotary KTM240D46UKT2, with standard crankcase heater.
GREE: compressor with heating element.
Same sheetsMIDEA: 5 speeds, from 630 to 824 cfm; static pressure 0 to 1.0 in. w.c.
GREE: 5 speeds; 760 cfm at 1.0 in. w.c.
Same sheetsA small system is heard mostly at low speed
MIDEA publishes its 2-ton air handler at 33 dB(A) on low speed and 47.5 dB(A) at its loudest; GREE gives one sound pressure value for its own, 50 dB(A). Outdoors: 59 dB(A) for the MIDEA, 60 dB(A) for the GREE. Neither sheet gives the measuring distance.
How to read these numbers. dB(A) measures a noise level as the ear perceives it: the lower the number, the quieter the unit. Each dot is a published value.
Why this is not a ranking. Neither manufacturer states its measuring conditions; different method, not comparable to the decibel.
Air handler, inside the house
Published values
Outdoor unit
Published values
In a small house, the system spends much of the winter at the bottom of its range (see “The small house”): the low-speed value is the one that matters day to day. Each manufacturer measures its own way; these values are reference points, not a ranking.
Two very different sizes for the same output
Outdoor units, to the same scale


Photos from the 2-ton submittal sheets, to the same scale: the MO1HE-H24B-2A, low and wide, stands 26 1/2 in tall; the FXU24 stands 37 13/16 in.
Air handlers, to the same scale


Series images of the air handlers, to the same scale: 53 7/8 in tall for the MAUSE-H24B-2A, 43 1/2 in for the FXU24HP230V1R32AH.
Line length between the two units
| Installation | EVOX G3 · 2 tons | FLEXX ULTRA R32 · 2 tons |
|---|---|---|
| Maximum piping length | Not stated on the 2-ton submittal sheet | 164 ftminimum 10 ft |
| Pre-charged length | 25 ft (7.5 m)0.7 oz per ft beyond | 31 ft0.323 oz per ft beyond |
| Maximum height difference | 82 ft (25 m) | 98 ft |
| Liquid – gas diameters | 3/8 – 3/4 in, flare connections | 3/8 – 3/4 in, flare connections |
| Refrigerant, factory charge | R-454B, 74 oz (2.1 kg) | R-32, 88.2 oz |
| Outdoor unit W × H × D, weight | 35 × 26 1/2 × 13 1/2 in, 102 lb | 39 × 37 13/16 × 14 9/16 in, 187.4 lb |
| Indoor unit W × H × D, weight | 14 1/2 × 53 7/8 × 21 1/2 in, 123 lb | 18 1/8 × 43 1/2 × 21 1/4 in, 135.6 lb |
| Electrical protection | Outdoor: MCA 19 A, MOP 20 A; indoor: MCA 3.5 A, MOP 15 A208/230 V | Outdoor: MCA 21 A, MOCP 25 A; indoor: MCA 4.7 A, MOCP 15 A208-230 V |
| Indoor fan airflow | 5 speeds: 824, 759, 694, 630 and 630 cfm | 5 speeds; 760 cfm at 1.0 in. w.c. |
| Published heating / cooling range | −30 to 24 °C / −30 to 50 °C | −30 to 24 °Clow heating limit: −22 °F |
Sources: MIDEA submittal sheet MAUSE-H24B-2A / MO1HE-H24B-2A (undated); GREE submittal sheet GREE_FXU24_230V_R32_SUB_05162025. The GREE sheet also shows a depth of 29 3/4 in on its drawing, without explanation; the page follows its specification table. Calculating a home's electrical service is a job for a master electrician.
What people ask us about these two 2-ton systems
Why talk about the lowest output?
A well-insulated house asks for little heat for most of the winter. When demand drops below the lowest certified output, the heat pump stops and restarts instead of slowing down. At 8.3 °C, the EVOX G3 certificate gives 6,600 BTU/h minimum, the FLEXX ULTRA certificate 10,800 BTU/h.
And in extreme cold?
At −30 °C, both certificates give a maximum output: 12,100 BTU/h for the EVOX G3, 18,000 BTU/h for the FLEXX ULTRA. Beyond what it delivers, the electric backup takes over. The slider in “The small house” shows the heat loss at which that happens.
Is the 2-ton just a smaller 3-ton?
No. Each size has its own AHRI certificate: 215471340 (EVOX G3) and 215213329 (FLEXX ULTRA) for the 2-ton. At MIDEA, the 2-ton outdoor unit (MO1HE-H24B-2A, 35 × 26 1/2 in) is smaller than the one in the 3-ton sold by AirGreen (MO1SE-H36B-2A, 38 9/16 × 38 3/8 in). The 3-ton comparison has its own page.
Why is the GREE outdoor unit so much bigger?
GREE publishes the same outdoor dimensions for the 2-ton and 3-ton FLEXX ULTRA (39 × 37 13/16 × 14 9/16 in, 187.4 lb). MIDEA publishes 35 × 26 1/2 × 13 1/2 in and 102 lb for the 2-ton EVOX G3. Plan the space and the support accordingly.
Are both ENERGY STAR certified?
The NEEP records of both certificates show ENERGY STAR and the cold-climate criterion.
Do they use the same refrigerant?
No: R-454B for the EVOX G3 (GWP 466, IPCC AR4) and R-32 for the FLEXX ULTRA (GWP 675, IPCC AR4), both class A2L under ASHRAE 34.
The certificate values, side by side
| Certified value | EVOX G3 · 2 tons | FLEXX ULTRA R32 · 2 tons |
|---|---|---|
| Certificate | ||
| AHRI certificate · NEEP record | 215471340 · 387399MAUSE-H24B-2A + MO1HE-H24B-2A | 215213329 · 504980FXU24HP230V1R32AH + FXU24HP230V1R32AO |
| ENERGY STAR (NEEP record) | Yes, cold-climate criterion included | Yes, cold-climate criterion included |
| Refrigerant | R-454B · GWP 466 (IPCC AR4) · class A2L | R-32 · GWP 675 (IPCC AR4) · class A2L |
| Seasonal efficiency | ||
| SEER2 | 18.6 | 18 |
| EER2 | 12 | 12 |
| HSPF2 Region IV | 10 | 10 |
| HSPF2 Region V | 8.1 | 7.6 |
| Certified heating, BTU/h | ||
| Min. / rated / max. capacity at 8.3 °C | 6,600 / 24,000 / 29,200 | 10,800 / 25,000 / 25,400 |
| Min. / rated / max. capacity at −8.3 °C | 4,900 / 20,800 / 20,800 | 7,100 / 20,600 / 21,600 |
| Min. / rated / max. capacity at −15 °C | 5,300 / 20,600 / 20,600 | 14,000 / 25,000 / 25,000 |
| COP at 8.3 °C (lowest, rated, highest output) | 4.84 / 3.50 / 3.49 | 5.11 / 3.59 / 3.56 |
| COP at −15 °C (lowest, rated, highest output) | 2.07 / 2.14 / 2.14 | 2.55 / 2.00 / 2.00 |
| Coldest certified point | ||
| Test temperature | −30 °C (−22 °F) | −30 °C (−22 °F) |
| Capacity at the coldest point (lowest / highest) | 2,500 / 12,100 BTU/h | 13,400 / 18,000 BTU/h |
| COP at the coldest point (lowest / highest output) | 1.08 / 1.40 | 1.37 / 1.36 |
| Cooling | ||
| Rated capacity at 35 °C | 24,000 BTU/hmin. 6,400, max. 28,800 | 24,000 BTU/hmin. 11,200, max. 24,000 |
“higher” marks the higher value of the same measure, under the same conditions. It is not a recommendation. At the coldest point, both are measured at −30 °C: the values compare directly, but this group is not highlighted.
Both are on the AirGreen website.
To choose for your home, talk it over with our team: bring the heated area, the condition of the ducts, the space planned for the outdoor unit and your current heating.
Documents reviewed
Data verified November 10, 2026. Performance: AHRI certificates and the NEEP database. Dimensions, sound, piping, electrical data and features: per the manufacturer. When a source contradicts the AHRI certificate, the certificate prevails.
Trademarks. MIDEA, EVOX, GREE and FLEXX are trademarks of their respective owners. Logos are used only to identify the products compared. AirGreen is a dealer of both brands; this page is not produced, sponsored or endorsed by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us at sales@airgreen.ca: every reported figure is checked and corrected if needed.