KINGHOME Multi-Zone R32 1-Way Ceiling Cassette | 9,000 BTU
A linear cassette for the bedroom or office where nothing else fits
Some rooms just won't take a wall-mounted heat pump. The wall is taken up by a closet, a bookcase or a headboard, the window spans the full width, or the owner simply doesn't want anything on the walls. The KINGHOME 9,000 BTU 1-way ceiling cassette is made for exactly this case: it sits inside the ceiling, shows only a narrow decorative panel and blows air in a single direction, along the full length of the room.
At AirGreen, we mostly recommend it for bedrooms, home offices and small closed rooms in a finished basement. In Montréal condos, it often fits into the bulkhead that already runs along the hallway or the window wall, where the ductwork and plumbing pass. It's the smallest capacity in the 1-way series, and the one best suited to a room where people sleep.
An indoor head that's part of a multi-zone system
This cassette never works on its own. It has no dedicated outdoor unit, no AHRI number of its own and no independent efficiency rating: it connects to a KINGHOME Ultra Heat multi-zone heat pump running on R-32 refrigerant, which also serves the other rooms in the house. Its 220 V power comes from the outdoor unit, through the interconnect cable. Heating and cooling performance, the operating range and the certification therefore belong to the complete system, not to the head.
The 9,000 BTU is one of the sizes accepted by every outdoor unit in the Ultra Heat range, according to the manufacturer's compatibility table:
- KM18X6O (up to 2 zones) and KM24X6O (up to 3 zones), for a condo or a single floor;
- KM30X6O and KM36X6O (up to 4 zones), for a single-family home;
- KM42X6O and KM48X6O (up to 5 zones) and KM60X6O (up to 6 zones), for a large home.
The 18,000 to 48,000 BTU outdoor units carry the ENERGY STAR cold climate designation and heat down to -30 °C. The one exception: the 60,000 BTU unit doesn't have this designation, something we always explain before recommending it. The most common setup for this model is still a 2-zone system: a wall-mounted head in the condo's open-plan living area, and this cassette in the primary bedroom.
Why the 1-way format suits a bedroom
An 8-way cassette goes in the middle of a room and spreads air in every direction. In a narrow bedroom, that's not ideal: part of the airflow hits the nearest wall and bounces back toward the bed. The 1-way cassette does the opposite. Installed near the exterior wall, above the window or at the room's entrance, it blows air along the room's long axis, above the occupants, with no direct draft on the pillow.
The housing measures 38.86 in. long by 15.16 in. wide, and is only 7.01 in. thick. That slim profile is the deciding factor in many projects: it allows installation in a shallow drop ceiling or between joists, where a square cassette wouldn't have enough room. The closed air intake and the wave-textured panel give it a clean finish, and the manufacturer offers several panel options. The cross-flow blade guides air along the length of the room for faster heating and cooling.
Modest numbers, chosen for a small room
- Nominal capacity: 9,000 BTU
- Maximum airflow: 324 CFM
- Indoor sound level: 31 dB(A) at low speed, 37 dB(A) at maximum speed
- Dehumidification: 1.69 pt/h, or about 0.8 L/h
- Refrigerant: R-32
The key figure for a bedroom is the very narrow sound range: even at maximum speed, the unit stays at 37 dB(A), according to the manufacturer's data sheet. Low speed, at 31 dB(A), is how it normally runs at night once the set point is reached.
Dehumidification matters too. A small room cooled by an oversized unit gets cold and clammy, because the coil doesn't run long enough to remove the moisture. That's why we don't automatically put a 12,000 BTU unit in a bedroom: the 9,000 BTU runs longer, more gently, and leaves the air drier.
Features and controls
An infrared remote is included. Wi-Fi is available as an option, through a Wi-Fi wired controller compatible with the KINGHOME app, and the manufacturer also offers a wall-mounted or flush-mounted wired controller. The I-feel function sets the temperature based on the reading taken at the remote, so close to the occupant rather than at the ceiling. Add to that coil self-cleaning, forced defrost, soft start, low-voltage start-up and a frost-protection maintenance heating mode, handy for a room that's rarely used in winter.
What we check before installation
A cassette goes into a ceiling, and a ceiling isn't easy to redo. During our assessments in Montréal, Laval, Longueuil, the North Shore and the South Shore, we check the following points before confirming a quote.
Ceiling space and structure
We measure the free space above the finished ceiling: the 7.01 in. thick housing has to fit with the clearances specified by the manufacturer. In a drywall ceiling, we plan the opening and a service access; in a drop ceiling, we check the grid. The cassette hangs from the structure on threaded rods anchored in the joists, never from the drywall or the drop-ceiling rails.
Power supply
The head has no breaker of its own: the outdoor unit determines the demand at the panel. For example, the KM18X6O requires a minimum circuit ampacity (MCA) of 15 A and a maximum overcurrent protection (MOP) of 20 A; the KM24X6O, an MCA of 20 A and an MOP of 25 A. These requirements work with most condo panels, but we always check the available space and the capacity of the electrical service.
Outdoor unit location
We prefer a wall bracket that keeps the outdoor unit above the snow buildup and lets defrost water drain away. In a condo, we also check the condo association's rules for the balcony or the façade, and the distance from the neighbours' windows.
Piping and drain
The 18,000 to 48,000 BTU outdoor units have 1/4 and 3/8 in. ports. We plan the refrigerant line route through the ceiling, insulated along its entire length, with as few elbows as possible. The cassette has a built-in condensate pump that lifts the water to a drain point: we confirm that discharge point before installation and test the drainage with water at start-up. Finally, the vacuum is pulled all the way, with no shortcuts, because moisture left in the circuit wears out the compressor.
The LogisVert grant
This indoor head doesn't appear on its own on Hydro-Québec's LogisVert grant list; eligibility is confirmed on the installation date. The financial assistance is tied to the complete multi-zone system, meaning the Ultra Heat outdoor unit and the certified combination. We confirm this for your specific combination when we prepare the quote.
Why choose AirGreen
- Salaried refrigeration technicians trained on KINGHOME multi-zone systems.
- Civil liability insurance of $5,000,000.
- Warranty registration done by us, at start-up.
- After-sales service that knows your installation, from Montréal to the South Shore.
Request your free estimate: we assess the bedroom or office, the space available in the ceiling and your electrical panel, then give you a clear quote for the complete multi-zone system.
Documentation
Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models; an additional warranty may be available.