ARCOAIRE R4A4S Economy Central Air Conditioner | 2 Tons - 24000 BTU - R410A
The 2-ton R4A4S R-410A condensing unit: an economy replacement for an existing central air system, available while supplies last.
Model numberR4A4S24AKANA
514 316-2973 · sales@airgreen.ca
Quick facts
When the old 2-ton air conditioner gives out: an economy R-410A replacement
A direct replacement for a house that is already equipped
The scenario is common: the house has had central air for years, the electric furnace and the ducts are in good condition, but the condensing unit outside will not start again. There is not always a reason to redo everything. The R4A4S24AKANA, the 2-ton (24,000 BTU/h) outdoor unit of ICP's economy R4A4S series, replaces that part, on R-410A, with a single-stage scroll compressor. It is available while supplies last.
The key question is the indoor coil. It can be reused only if it is R-410A compatible and matched according to the manufacturer; this condensing unit's capacity tables use the ESD4X24M14A1E section. If the coil in place is not suitable, we include its replacement in the same quote, rather than pair two mismatched units.
The same logic applies to the refrigerant piping: this size has a 3/4 in vapor valve and a 3/8 in liquid valve, and we check the diameter and condition of the existing lines before reusing them. And if a reasonable repair is enough to get the old unit running again, we tell you that too.
The data published for this size
The spec sheet, published under the Maratherm brand, another ICP banner, gives a range of 13.4 to 16.0 SEER2 depending on the matched indoor section. There is no certified rating for the condensing unit alone. The published sound power is 74 dBA.
The compressor has an internal pressure relief valve and internal thermal overload, and the unit has a filter drier and a dense wire coil guard. For the electrical side, plan a 208/230 V single-phase circuit with a 15.1 A minimum ampacity and a 25 A maximum time-delay fuse or breaker.
This condensing unit does not heat and, sold alone, it is not eligible for the LogisVert grant. If the furnace is also nearing the end, a central heat pump may be worth comparing.
On installation day
AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. After a free on-site estimate and a written quote, our technicians:
- recover the refrigerant from the old condensing unit and remove it;
- set the R4A4S24AKANA level on its pad;
- check or replace the indoor coil and the piping;
- evacuate, adjust the charge to the actual length and connect the power;
- commission the system and check its operation.
We work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
Get your cool back
Ask for your free estimate: we assess the installation in place, confirm availability and give you a written quote. Financing is available.
Replacing a 2-ton condensing unit without redoing everything
The R4A4S24AKANA replaces the outdoor unit of a split central air conditioner. It works with a matched indoor section, a coil on an electric furnace or a fan coil; its capacity tables are built with the ESD4X24M14A1E section.
- Replacing a 2-ton condensing unit at the end of its life
- Single-storey and semi-detached houses already cooled through ducts
- Projects where budget comes before maximum efficiency
- Adding central air to an existing electric furnace
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Available while supplies last.
- Cooling only. Sold alone: not eligible for the LogisVert grant.
- The existing indoor coil can be reused only if it is R-410A compatible and matched according to the manufacturer.
- 208/230 V single-phase, 60 Hz circuit: 15.1 A minimum ampacity, 25 A maximum time-delay fuse or breaker.
- The factory charge is topped up on site according to the actual piping length.
- Spec sheet published under the Maratherm brand; dimensions and weight given only on a drawing.
Manufacturer documents
Explore the range
Central air conditionersSee allSame brand
ARCOAIRESee all
Frequently asked questions
Can I keep my current indoor coil?
Only if it is R-410A compatible and matched according to the manufacturer. This condensing unit's capacity tables use the ESD4X24M14A1E section. We check the coil in place before proposing to keep it.
What electrical circuit is needed?
A 208/230 V single-phase circuit with a 15.1 A minimum ampacity and a 25 A maximum time-delay fuse or breaker, according to the spec sheet.
Is it loud?
The spec sheet publishes a sound power of 74 dBA for this size, measured under the AHRI 270 test standard. The unit's location also matters: we choose it with you.
Why the Maratherm name on the spec sheet?
The R4A4S is made by ICP and its spec sheet is published under the Maratherm brand. The ICP limited warranty certificate covers the R4A4S series.
What is the manufacturer's warranty?
According to the ICP limited warranty certificate: parts for 10 years for the original owner with registration within 90 days of installation, otherwise 5 years; the certificate states that this registration condition does not apply in Quebec. Subsequent owners: 5 years. Labour is not covered by the manufacturer.
A 2-ton central air conditioner, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 19, 2026.