The RSH-50 from RectorSeal is a surge protective device (surge protector) for single-phase 120/240 V AC equipment. It protects air conditioners, heat pumps and ductless wall-mounted heat pumps against transient surges, whether they come from a storm or from the grid.
Certified protection, mounted at the unit
The RSH-50 mounts with a 1/2 in nipple into a knockout on the disconnect or the unit, on the outdoor unit as well as on the indoor air handler. RectorSeal combines a gas discharge tube (GDT) and thermally fused varistors (TFMOV). A green light shows that protection is active.
Manufacturer specifications
- Maximum discharge current: 50 kA
- Short-circuit current rating: 200 kA
- Maximum continuous operating voltage: 150 V AC line-to-ground, 300 V AC line-to-line
- UL 1449 Type 1 listing, NEMA 4X enclosure, 50/60 Hz
- Manufacturer's limited lifetime warranty on the product
On its own or with a disconnect
The RSH-50 is available on its own, for a disconnect that is already in place, or in a version with a disconnect that combines shutoff and protection. It is designed for single-phase equipment; a three-phase unit needs a different model. The connection must be made by qualified personnel, in accordance with the Electrical Code.
Installed by AirGreen in Greater Montréal
We add it when installing your heat pump or during a service visit in Montréal, Laval, Longueuil, on the South Shore and the North Shore. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with the version (on its own or with a disconnect) and the model of your unit.
Protection mounted right at the equipment
The RSH-50 threads into a 1/2 in knockout on the disconnect or the unit and protects the circuit feeding it.
- Outdoor heat pump and air conditioner units
- Indoor units and air handlers
- Ductless wall-mount heat pumps
- Single-phase 120/240 V equipment, residential or commercial
2 sizes, one page
Each size has its own AirGreen code. Tap a row to select it.
| Model | AirGreen code |
|---|---|
| Without disconnect | AG-EL-00601 |
| With disconnect | AG-EL-00602 |
Available alone or with a disconnect. Tell us which version you need.
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- The RSH-50 is designed for single-phase 120/240 VAC systems.
- It mounts on a 1/2 in nipple, into a knockout on the disconnect or the unit.
- Wiring must be done by qualified personnel, to the Electrical Code.
- Check the green LED after installation and at each annual maintenance.
Manufacturer documents
You may also need
Outdoor Disconnect Switch for Heat Pump
Surge Protector for HVAC Equipment – 20 kA
Copper Electrical Wire
Breaker for Residential Electrical Panel
14/4 Communication Cable for Heat PumpsElectricalSee all
Frequently asked questions
Is my unit compatible?
RectorSeal designs it for single-phase 120/240 VAC equipment: outdoor units, air handlers, heat pumps and ductless wall-mount heat pumps. Three-phase equipment needs a different model.
What does the green LED mean?
It shows that protection is active. If it is off while the unit has power, have the device checked.
How is the disconnect version different?
The disconnect version combines surge protection and the unit’s means of disconnect in one assembly. Tell us which one you want and we confirm the format before ordering.
Can you install it?
Yes. We add it when we install your heat pump or during a service visit, with the wiring done by qualified personnel.
Protect your heat pump with the RSH-50
Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 7, 2026.