RectorSeal RSH-50 Surge Protective Device

In stock

RectorSeal’s surge protective device for single-phase 120/240 V heat pumps and air conditioners.

AirGreen codeAG-EL-00602

50 kAmaximum discharge current
200 kAshort-circuit current rating
NEMA 4Xoutdoor-rated
UL 1449 Type 1120/240 V
Model
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-EL-00602
ManufacturerRectorSeal
ModelRSH-50
Voltage120/240 VAC, single phase
Mounting1/2 in nipple
IndicatorGreen LED

The RSH-50 from RectorSeal is a surge protective device (surge protector) for single-phase 120/240 V AC equipment. It protects air conditioners, heat pumps and ductless wall-mounted heat pumps against transient surges, whether they come from a storm or from the grid.

Certified protection, mounted at the unit

The RSH-50 mounts with a 1/2 in nipple into a knockout on the disconnect or the unit, on the outdoor unit as well as on the indoor air handler. RectorSeal combines a gas discharge tube (GDT) and thermally fused varistors (TFMOV). A green light shows that protection is active.

Manufacturer specifications

  • Maximum discharge current: 50 kA
  • Short-circuit current rating: 200 kA
  • Maximum continuous operating voltage: 150 V AC line-to-ground, 300 V AC line-to-line
  • UL 1449 Type 1 listing, NEMA 4X enclosure, 50/60 Hz
  • Manufacturer's limited lifetime warranty on the product

On its own or with a disconnect

The RSH-50 is available on its own, for a disconnect that is already in place, or in a version with a disconnect that combines shutoff and protection. It is designed for single-phase equipment; a three-phase unit needs a different model. The connection must be made by qualified personnel, in accordance with the Electrical Code.

Installed by AirGreen in Greater Montréal

We add it when installing your heat pump or during a service visit in Montréal, Laval, Longueuil, on the South Shore and the North Shore. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with the version (on its own or with a disconnect) and the model of your unit.

01 · What it is for

Protection mounted right at the equipment

The RSH-50 threads into a 1/2 in knockout on the disconnect or the unit and protects the circuit feeding it.

  • Outdoor heat pump and air conditioner units
  • Indoor units and air handlers
  • Ductless wall-mount heat pumps
  • Single-phase 120/240 V equipment, residential or commercial
Hybrid technologyGas discharge tube (GDT) and thermally fused metal oxide varistors (TFMOV).
Green LEDShows at a glance that protection is active.
Built for outdoorsNEMA 4X weather rating, UL 1449 Type 1 listed.
02 · Sizes

2 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

ModelAirGreen code
Without disconnectAG-EL-00601
With disconnectAG-EL-00602

Available alone or with a disconnect. Tell us which version you need.

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerRectorSeal
ModelRSH-50
Part no. (without disconnect)96415
Voltage120/240 VAC, single phase
Frequency50/60 Hz
Maximum discharge current (Imax)50 kA
Short-circuit current rating (SCCR)200 kA
Maximum continuous operating voltage (MCOV)150 VAC L-G, 300 VAC L-L
TechnologyGDT and TFMOV
ListingUL 1449, Type 1
EnclosureNEMA 4X
Mounting1/2 in nipple
IndicatorGreen LED
Manufacturer warrantyLimited lifetime (product replacement)
StandardsUL 1449 type 1
AirGreen codeAG-EL-00602
04 · Before installing

What to know before installing

  • The RSH-50 is designed for single-phase 120/240 VAC systems.
  • It mounts on a 1/2 in nipple, into a knockout on the disconnect or the unit.
  • Wiring must be done by qualified personnel, to the Electrical Code.
  • Check the green LED after installation and at each annual maintenance.
05 · Documents

Manufacturer documents

06 · Goes with

You may also need

Same category
Electrical
See all
07 · Questions

Frequently asked questions

Is my unit compatible?

RectorSeal designs it for single-phase 120/240 VAC equipment: outdoor units, air handlers, heat pumps and ductless wall-mount heat pumps. Three-phase equipment needs a different model.

What does the green LED mean?

It shows that protection is active. If it is off while the unit has power, have the device checked.

How is the disconnect version different?

The disconnect version combines surge protection and the unit’s means of disconnect in one assembly. Tell us which one you want and we confirm the format before ordering.

Can you install it?

Yes. We add it when we install your heat pump or during a service visit, with the wiring done by qualified personnel.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Protect your heat pump with the RSH-50

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom