Échangeur d'Air Fantech ERV FIT 120E-M-HC | Montréal, Laval, Longueuil, Rive Sud et Rive Nord

In stock
SKU: FIT 120E-M-HC
127 cfm net1,500 to 2,400 sq ft61% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeRénoclimat $500Core warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 127 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.

It's the right size.

For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 127 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
61%
At −25 °CCode: 54% minimum
74%
At 0 °CCertified at 51 cfm
Net airflowThe ducts cost it 19 cfm
0.2 in · test bench146 cfm
0.4 in · with ducts127 cfm

$53.68

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

55W
Running continuously
482kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 61% at 51 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 55 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

-MMirrored version: dwelling-side ports on the left

On the FIT 120E, the dwelling's supply and return air connect on the right-hand side; on the FIT 120E-M-HC, they move to the left. One building can thus serve mirror-image floor plans, with the installation drawings simply read in reverse.

-HCHard-connect version shipped without a cord

The -HC (hard connect) suffix means the unit ships with no power cord and is wired directly to the circuit where code requires it. On the FIT 120E-M-HC, the supply wires enter the electrical box through a 3/8 in cable fastener and connect to the unit's leads and ground screw.

61%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005120Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.

−19 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 127 cfm. Most spec sheets show only the first number, precisely because it looks better.

55 WMeasured at the airflow it actually runs at

Its 74% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 55 W, or about 482 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years. We register the warranty in your name at commissioning.

5 inWhat it needs on site

5 in ducts, side connection. It weighs 34 lb, and it needs enough clearance to slide the core out once a year.

Grant

Rénoclimat: $500 to install or replace an HRV or ERV

First condition met: HVI Section III certified, No. 2005120. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.

$500
04 · Installation

What it needs on site

5 in ductsCollar diameter
Side connectionSide ports
34 lbUnit weight
23.16 × 20.75 × 10.06 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
146 cfm
Net airflow at 0.4 in. w.g.
127 cfm
SRE at 0 °C (51 cfm)
74%
SRE at −25 °C (51 cfm)
61%
ASE at 0 °C
81%
Power draw
55 W
Efficacy
0.9 cfm/W
Type
ERV
Connection
Side ports
Duct collars
5 in
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in); optional MERV 8 (461674) and MERV 13 (461675)
Dimensions (L × D × H)
23.16 × 20.75 × 10.06 in
Weight
34 lb
Power supply
120 V
HVI certification (Section III)
2005120
Warranty — core
5 years
Warranty — motors
7 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005120). Annual consumption calculated at 55 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Un grand VRE sans cordon, raccords à gauche

Le Fantech FIT 120E-M-HC est pensé pour les grands logements d'immeubles neufs : unités de plusieurs chambres, maisons de ville, derniers étages. Il combine la configuration miroir, qui place l'alimentation et le retour d'air du logement du côté gauche, et un raccordement électrique permanent, sans cordon. Son débit net est de 127 pcm à 0,4 po.

Sans volet motorisé, ce ventilateur récupérateur d'énergie (VRE) est fait d'abord pour une installation entièrement dédiée, avec son propre réseau de conduits.

Une installation indépendante du chauffage

Fantech suggère cette méthode avec les plinthes électriques, le chauffage hydronique, le plancher radiant ou une thermopompe murale. L'air neuf va aux chambres et aux pièces principales; l'air vicié est repris dans la salle de bain, la cuisine et la salle de lavage. Le fabricant demande des conduits galvanisés vers les pièces principales, des branches d'au moins 4 po, et des joints vissés ou scellés au mastic.

Les commandes

Une minuterie de salle de bain RTS4 fait passer l'appareil en haute vitesse pendant 20, 40 ou 60 minutes. Un déshumidistat MDEH1 force la haute vitesse quand l'humidité dépasse le point de consigne. La commande ECO-Touch Auto IAQ, à écran tactile, ajuste la ventilation selon les COV, garde ses réglages après une panne de courant et accepte la minuterie sans fil RTS-W. Pour un usage multilogement, Fantech propose aussi l'ECO-Feel, sans aucun réglage pour l'occupant.

Le raccordement permanent

Un serre-câble de 3/8 po, les fils du circuit reliés aux fils et à la vis de mise à la terre de l'appareil : c'est tout ce que demande la version HC. Certains codes et devis l'imposent en construction neuve. Il faut 2 3/8 po libres au-dessus du boîtier électrique.

Mise en service et équilibrage

À la mise sous tension, l'appareil fait dix secondes de dégivrage par évacuation seule, puis prend le mode choisi. Nous vérifions les trois positions du sélecteur, MIN, AUTO et MAX, avant de brancher la commande murale. L'équilibrage se fait avec une commande tactile Fantech et un manomètre : on mesure l'air vicié, puis l'air neuf, et on ajuste chaque ventilateur par pas de 1 % en haute vitesse. Les deux autres vitesses suivent. La pression et les débits sont notés au rapport de mise en service, que le propriétaire signe avec nous.

Performance

À 51 pcm, l'efficacité de récupération sensible est de 74 % à 0 °C (81 % ajustée) et de 61 % à −25 °C, ce qui dépasse le seuil de 54 % de la section 9.32 du Code pour le Grand Montréal. La récupération totale est de 64 % à 35 °C. Consommation : 55 W au débit d'essai, 104 W en haute vitesse.

Pourquoi cette combinaison

Nous recommandons le FIT 120E-M-HC quand trois conditions sont réunies : un logement orienté à l'inverse, aucun système à air pulsé et un raccordement fixe exigé. Si le logement a une fournaise, le FIT 120E-D-M-HC ajoute le volet. Si une prise suffit, le FIT 120E-M fait le même travail avec son cordon. Pour un immeuble, nous établissons la liste par unité.

Les hottes extérieures

Nous plaçons la prise d'air neuf à au moins 18 po du sol ou au-dessus du niveau de neige, et à au moins 3 pi des coins. Elle reste à distance des sorties de sécheuse, des compteurs de gaz, des entrées de garage et des poubelles. Les conduits isolés vers les hottes sont tendus, le plus courts possible, et scellés au mastic acoustique. Une hotte tandem est possible là où la réglementation l'accepte.

Fiche d'installation

  • 23,16 × 20,75 × 10,06 po, 34 lb.
  • Raccordement latéral, conduits ronds de 5 po.
  • Aucun drain.
  • Accès à prévoir : 8 1/2 po devant la porte, 2 3/8 po au-dessus du boîtier.
  • Filtres : deux MERV 3 lavables de 11 5/16 × 8 1/8 po; MERV 8 (461674) et MERV 13 (461675) en option.
  • Garantie Fantech : noyau 5 ans, moteurs 7 ans, composants électriques 5 ans.

AirGreen installe votre FIT 120E-M-HC

Du centre de Montréal jusqu'à Laval, Longueuil, la Rive-Nord et la Rive-Sud, nous posons ce type d'appareil en construction neuve comme en rénovation. Le calcul de ventilation par pièce selon CSA F326 détermine le débit; nous posons les conduits dédiés et les hottes, puis nous équilibrons l'alimentation et l'évacuation à la valeur calculée.

Le FIT 120E-M-HC est homologué à la section III du répertoire HVI sous le no 2005120. Il peut rendre le projet admissible à l'aide Rénoclimat de 500 $, pourvu que la cote ÉnerGuide s'améliore entre les deux évaluations et que l'évaluation soit faite avant le début des travaux.

Soumission gratuite : 514 316-2973 ou sales@airgreen.ca.