Fantech ERV FIT 120E-M-HC Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 127 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 127 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$53.68
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 61% at 51 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 55 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
-MMirrored version: dwelling-side ports on the left
On the FIT 120E, the dwelling's supply and return air connect on the right-hand side; on the FIT 120E-M-HC, they move to the left. One building can thus serve mirror-image floor plans, with the installation drawings simply read in reverse.
-HCHard-connect version shipped without a cord
The -HC (hard connect) suffix means the unit ships with no power cord and is wired directly to the circuit where code requires it. On the FIT 120E-M-HC, the supply wires enter the electrical box through a 3/8 in cable fastener and connect to the unit's leads and ground screw.
61%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005120Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−19 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 127 cfm.
55 WMeasured at the airflow it actually runs at
Its 74% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 55 W, or about 482 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
5 inWhat it needs on site
5 in ducts, side connection. It weighs 34 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005120) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 146 cfm
- Net airflow at 0.4 in. w.g.
- 127 cfm
- SRE at 0 °C (51 cfm)
- 74%
- SRE at −25 °C (51 cfm)
- 61%
- ASE at 0 °C
- 81%
- Power draw
- 55 W
- Efficacy
- 0.9 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 5 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in); optional MERV 8 (461674) and MERV 13 (461675)
- Dimensions (L × D × H)
- 23.16 × 20.75 × 10.06 in
- Weight
- 34 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005120
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005120). Annual consumption calculated at 55 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
A large ERV with no cord, connections on the left
The Fantech FIT 120E-M-HC is designed for large units in new buildings: multi-bedroom units, townhouses, top floors. It combines the mirror configuration, which puts the home's supply and return air on the left side, with a permanent electrical connection, without a cord. Its net airflow is 127 cfm at 0.4 in.
With no motorized damper, this energy recovery ventilator (ERV) is made first and foremost for a fully dedicated installation, with its own duct system.
An installation independent of the heating
Fantech suggests this method with electric baseboards, hydronic heating, radiant floor heating or a wall-mounted heat pump. Fresh air goes to the bedrooms and main living areas; stale air is drawn from the bathroom, the kitchen and the laundry room. The manufacturer calls for galvanized ducts to the main living areas, branches of at least 4 in., and joints that are screwed or sealed with mastic.
Controls
An RTS4 bathroom timer switches the unit to high speed for 20, 40 or 60 minutes. An MDEH1 dehumidistat forces high speed when humidity rises above the set point. The ECO-Touch Auto IAQ touchscreen control adjusts ventilation based on VOCs, keeps its settings after a power outage and accepts the RTS-W wireless timer. For multi-unit buildings, Fantech also offers the ECO-Feel, with no settings at all for the occupant.
The permanent connection
A 3/8 in. cable clamp, the circuit wires connected to the unit's wires and grounding screw: that is all the HC version needs. Some codes and specifications require it in new construction. You need 2 3/8 in. of clearance above the electrical box.
Commissioning and balancing
At power-up, the unit runs ten seconds of exhaust-only defrost, then goes to the selected mode. We check the selector's three positions, MIN, AUTO and MAX, before connecting the wall control. Balancing is done with a Fantech touchscreen control and a manometer: stale air is measured, then fresh air, and each fan is adjusted in 1% steps at high speed. The other two speeds follow. The pressure and airflows are recorded on the commissioning report, which the owner signs with us.
Performance
At 51 cfm, sensible recovery efficiency is 74% at 0 °C (81% adjusted) and 61% at −25 °C, which exceeds the 54% threshold in section 9.32 of the Code for Greater Montreal. Total recovery is 64% at 35 °C. Power draw: 55 W at the test airflow, 104 W at high speed.
Why this combination
We recommend the FIT 120E-M-HC when three conditions are met: a home laid out in reverse, no forced-air system and a fixed connection that is required. If the home has a furnace, the FIT 120E-D-M-HC adds the damper. If an outlet is enough, the FIT 120E-M does the same job with its cord. For a building, we draw up the list unit by unit.
The exterior hoods
We place the fresh air intake at least 18 in. above the ground or above the snow line, and at least 3 ft from corners. It stays away from dryer vents, gas meters, garage entrances and garbage bins. The insulated ducts to the hoods are pulled taut, kept as short as possible and sealed with acoustical sealant. A tandem hood is possible where regulations allow it.
Installation sheet
- 23.16 × 20.75 × 10.06 in., 34 lb.
- Side connection, 5 in. round ducts.
- No drain.
- Access to plan for: 8 1/2 in. in front of the door, 2 3/8 in. above the box.
- Filters: two washable MERV 3, 11 5/16 × 8 1/8 in.; MERV 8 (461674) and MERV 13 (461675) as options.
- Fantech warranty: core 5 years, motors 7 years, electrical components 5 years.
AirGreen installs your FIT 120E-M-HC
From central Montreal to Laval, Longueuil, the North Shore and the South Shore, we install this type of unit in new construction as well as in renovation. The room-by-room ventilation calculation under CSA F326 determines the airflow; we install the dedicated ducts and the hoods, then balance supply and exhaust to the calculated value.
The FIT 120E-M-HC is certified in Section III of the HVI directory (no. 2005120): its airflows and efficiencies are published and verifiable by anyone. Since October 1, 2026, Rénoclimat no longer funds the installation of an HRV or an ERV; only files already open under the program's transition rules remain eligible.
Free quote: 514 316-2973 or sales@airgreen.ca.