ARCOAIRE D5FUAAH Electric Furnace | 1.5 Tons - 18000 BTU - R454B
Arcoaire’s 1.5-ton D5FUAAH air handler: a compact 45.00 in high cabinet, powered by 115 V or 208/230 V.
Model numberD5FUAAH18XAK
514 316-2973 · sales@airgreen.ca
Quick facts
A compact air handler for condos and small spaces
What the D5FUAAH18XAK is
In a central system, the outdoor unit produces the heat or cooling, but it is the air handler, indoors, that transfers it to the air and distributes it through the ducts. Arcoaire’s D5FUAAH18XAK plays that role for a 1.5-ton system. It is sold alone, without an outdoor unit: it is used to complete a system or replace an existing air handler, after the match is checked.
With a published airflow of 577 CFM, this size suits small spaces: a condo, an apartment with ductwork, a well-insulated ground floor.
Its place in a condo or small dwelling
In condos in Montreal and the surrounding area, the mechanical space often comes down to a hallway closet. The D5FUAAH18XAK is 45.00 in high, 17.52 in wide and 21.02 in deep, the smallest footprint in the series, shared with the 2-ton size. We add the service clearance the manufacturer requires to these dimensions before confirming that it fits.
Its power supply is another advantage for small dwellings: the cabinet accepts 115 V or 208/230 V, single phase. At 115 V, the minimum circuit ampacity is 5.5 A; at 208/230 V, 4 A, with a 15 A maximum overcurrent protection in both cases. Depending on the state of your panel, either option can simplify the connection.
Before ordering: the match
An air handler sold alone must be compatible with the outdoor unit, refrigerant included. The confirmed data for this model does not name a specific outdoor unit or an electric heat option. We therefore check the model number of your heat pump or air conditioner, and the 3/8 in (liquid) and 3/4 in (suction) connections, before any order. If your old air handler included electric backup heat, we take it into account in the quote.
Installation by AirGreen
We start with a free on-site estimate, then provide a written quote. On installation day, our technicians set the cabinet, connect the ducts, the refrigerant line set, the drain and the power supply, then commission the system. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work.
AirGreen is a family business established in Montreal for more than fifteen years. We also install in Laval, Longueuil, on the North Shore and on the South Shore.
Let’s talk about your project
Sold alone, this air handler does not qualify for the LogisVert grant: the grant follows a certified outdoor unit + air handler pair. If you are considering a complete system, we present that option too.
Ask for your free on-site estimate and receive a written quote. Financing is available for your project.
A compact air handler for small spaces
The D5FUAAH18XAK installs indoors and distributes air heated or cooled by the outdoor unit through the ductwork. At 45.00 in high and 17.52 in wide, it is aimed at closets and small mechanical rooms.
- Condos and apartments with ductwork
- Hallway closets and small mechanical rooms
- Locations supplied with 115 V or 208/230 V
- 1.5-ton central systems with a compatible outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Sold alone: not eligible for the LogisVert grant. The grant follows the certified outdoor unit + air handler pair.
- The matched outdoor unit and electric heat options are not in the confirmed data for this model: we confirm the match (model and refrigerant) before ordering.
- Plan room for a 45.00 x 17.52 x 21.02 in cabinet (H x W x D), plus the service clearance the manufacturer requires.
- 115 V or 208/230 V single-phase, 60 Hz power supply; 15 A maximum overcurrent protection (fuse).
Manufacturer documents
Explore the range
Electric furnaces – air handlersSee allSame brand
ARCOAIRESee all
Frequently asked questions
Which outdoor unit does it work with?
The confirmed data for this model does not name an outdoor unit. Send us your unit’s model number and we check compatibility, refrigerant included, before ordering.
Can it run on 115 V?
Yes. The manufacturer publishes a 115 V or 208/230 V single-phase supply: 5.5 A minimum circuit ampacity at 115 V or 4 A at 208/230 V, 15 A maximum overcurrent protection.
Will it fit in a closet?
It is 45.00 in high, 17.52 in wide and 21.02 in deep. Add the service clearance the manufacturer requires; we measure the location during the estimate.
Does this air handler qualify for a grant?
Not when it is sold alone. Hydro-Québec’s LogisVert grant follows a certified outdoor unit + air handler pair.
Can you install it?
Yes. Our technicians set the cabinet, connect it to the ductwork, the refrigerant line set, the drain and the power supply, then commission the system.
A 1.5-ton Arcoaire air handler, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 19, 2026.