ARCOAIRE FJMA4X Electric Furnace | 2.5 Tons - 30000 BTU - R410A

In stock

Arcoaire’s 2.5-ton FJMA4X air handler: the series’ in-between size, with 875 CFM nominal.

Model numberFJMA4X30L0BB

875 CFMnominal airflow
2.5 tons30,000 BTU/h nominal size
5.3 Aminimum circuit ampacity
208/230 V · single phaseSold alone, no outdoor unit
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberFJMA4X30L0BB
ManufacturerArcoaire
SeriesFJMA4X
Size2.5 tons (30,000 BTU/h)
Nominal airflow875 CFM
Minimum circuit ampacity5.3 A
Maximum overcurrent protection15 A

2.5 tons: the in-between size, in the same footprint

Why an in-between size

The size a house needs rarely lands on a round number. A semi-detached house in Longueuil, a mid-size two-storey home in Laval or a renovated house with new windows often ends up between 2 and 3 tons. Arcoaire’s FJMA4X30L0BB answers that case: it is the 2.5-ton (30,000 BTU/h) air handler of the FJMA4X series, with a published nominal airflow of 875 CFM.

Choosing the right size has real effects. A system that is too small runs non-stop in extreme cold; a system that is too large keeps starting and stopping, leaves temperature differences between rooms and removes humidity poorly in summer. The in-between size avoids both pitfalls when the house calls for it.

The same footprint as the neighbouring sizes

Arcoaire publishes a cabinet 49-5/8 in high, 17-5/8 in wide and 22-1/16 in deep for this model, the same dimensions as the 2-ton and 3-ton sizes of the series. For the installer, that is convenient: if the size chosen after the on-site assessment shifts by half a size, the room needed in the mechanical space does not.

The air handler runs on 208/230 V single phase, 60 Hz, with a 5.3 A minimum circuit ampacity and 15 A maximum overcurrent protection. The liquid connection is 3/8 in (9.5 mm), inside diameter.

Before ordering

The FJMA4X30L0BB is sold alone, without an outdoor unit. It therefore does not qualify for the LogisVert grant, which follows the certified outdoor unit + air handler pair. When you replace the whole system, we propose a 2.5-ton pair chosen from the manufacturer’s matches and check its eligibility.

No heater kit is described for this model in the data we verified. If you want electric backup heat, we confirm the compatible kit with the manufacturer before ordering.

What AirGreen’s installation covers

AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Our work always follows the same order:

  1. free on-site estimate and choice of size;
  2. written quote, including the matched outdoor unit;
  3. installing the air handler, connecting the plenum and ducts;
  4. refrigerant connection, vacuum, condensate drain and electrical connection;
  5. commissioning and adjustment with you.

We install in Montreal, on the South Shore, on the North Shore and throughout Greater Montreal.

Let’s run the numbers together

Book a free estimate: we confirm whether your house needs 2, 2.5 or 3 tons, then you receive a written quote. Financing is available.

01 · What it is for

When 2 tons is not enough and 3 tons is too much

The FJMA4X30L0BB fills the gap between the 2-ton and 3-ton sizes of the FJMA4X series. Installed indoors, it moves 875 CFM nominal through the ductwork, with an outdoor unit of the same capacity.

  • Semi-detached houses and mid-size two-storey homes with ductwork
  • Houses whose load calculation falls between 2 and 3 tons
  • Replacing a 2.5-ton air handler without changing the mechanical room
  • Completing a 2.5-ton central heat pump or central air conditioner
875 CFM nominalThe airflow Arcoaire publishes for the 2.5-ton size.
Same footprint as 2 and 3 tonsA 49-5/8 x 17-5/8 x 22-1/16 in cabinet (H x W x D), like the neighbouring sizes in the series.
5.3 A circuitPublished minimum ampacity, with 15 A maximum overcurrent protection at 208/230 V.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerArcoaire
SeriesFJMA4X
TypeAir handler (blower cabinet), sold alone
Nominal size2.5 tons (30,000 BTU/h)
Nominal airflow875 CFM
Power supply208/230 V, single phase, 60 Hz
Minimum circuit ampacity5.3 A
Maximum overcurrent protection15 A
Liquid connection3/8 in (9.5 mm), inside diameter
Dimensions (H x W x D)49-5/8 x 17-5/8 x 22-1/16 in
Model numberFJMA4X30L0BB
03 · Before installing

What to know before installing

  • Sold alone: the LogisVert grant follows the certified outdoor unit + air handler pair; this air handler alone does not qualify.
  • The outdoor unit is not included. It is chosen from the matches the manufacturer publishes.
  • No heater kit is described for this model in the verified data: for electric backup heat, we confirm the compatible kit before ordering.
  • Plan room for a 49-5/8 x 17-5/8 x 22-1/16 in cabinet (H x W x D), the plenum and the manufacturer’s service clearance.
  • 208/230 V single-phase, 60 Hz power supply; 3/8 in (9.5 mm) liquid connection, inside diameter.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces – air handlers
See all
Same brand
ARCOAIRE
See all
06 · Questions

Frequently asked questions

Why choose 2.5 tons rather than 2 or 3?

Because the house’s load calculation calls for it. An undersized unit struggles in extreme cold or heat; an oversized one short-cycles and dehumidifies poorly. We run that calculation before proposing a size.

Is the cabinet larger than the 2-ton one?

No. Arcoaire publishes the same dimensions for the 2, 2.5 and 3-ton sizes of the series: 49-5/8 in high, 17-5/8 in wide and 22-1/16 in deep.

What electrical circuit is needed?

A 208/230 V single-phase circuit with a 5.3 A minimum ampacity and 15 A maximum overcurrent protection, per Arcoaire’s data. We check the panel during the estimate.

Does it qualify for the LogisVert grant?

Not when sold alone. The grant follows a certified outdoor unit + air handler pair. For a full replacement, we check the pair’s eligibility in the quote.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2.5-ton Arcoaire air handler, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.