ARCOAIRE FXM4X Electric Furnace | 1.5 Tons - 18000 BTU - R410A

In stock

Arcoaire’s 1.5-ton FXM4X fan coil: a multiposition R-410A cabinet with an aluminum coil, TXV and constant-torque ECM motor.

Model numberFXM4X1800AL

600 CFMnominal airflow (283 L/s)
1.5 tons18,000 BTU/h nominal size
1/3 HPconstant-torque ECM motor, 5 taps
R-410A208/230 V · single phaseWashable filter suppliedHeating element not includedAvailable while supplies last
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberFXM4X1800AL
ManufacturerArcoaire
Size1.5 tons (18,000 BTU/h)
Nominal airflow600 CFM
RefrigerantR-410A
Power supply208/230 V, 1 ph, 60 Hz
Heater kitsEHK05, EHK07, EHK10

A compact fan coil to get a small R-410A central system running again

What the FXM4X1800AL is and who it suits

The FXM4X1800AL is the indoor part of a central system: a cabinet that holds the blower, the coil and the expansion valve. The outdoor unit, heat pump or air conditioner, sends it refrigerant; the cabinet turns that energy into warm or cool air and distributes it through your ducts. It does not produce heat on its own until a heater kit is added.

This 1.5-ton size is aimed at smaller spaces: a bungalow, a condo with ductwork, a well-insulated ground floor. It mainly suits homeowners whose R-410A air handler has failed while the outdoor unit still works, and contractors looking for a same-capacity replacement. The model is available while supplies last.

How it fits a Québec home

In our homes, the air handler often ends up in a corner of the basement, at the back of a closet or lying in a service space. The FXM4X handles all three: it installs upflow or horizontal left with no modification, horizontal right with a minor modification, and downflow with a conversion kit.

For winter, the cabinet can take electric backup heat. Arcoaire lists three kits for this size, 5, 8 or 10 kW, sold separately. We choose the right one based on the capacity of your electrical panel and the role the backup must play when the heat pump slows down in extreme cold.

The constant-torque ECM motor has five speed taps. At commissioning, we select the one that suits your ductwork instead of leaving the factory setting.

What AirGreen’s installation covers

We start with a free on-site estimate. We note the model of your outdoor unit, the condition of the ducts, the space available and the power supply, then we provide a written quote. If the FXM4X1800AL does not suit your outdoor unit, we tell you before ordering.

On installation day, our technicians remove the old cabinet, set the new one, connect the refrigerant line set, the drain and the power supply, add the heater kit if it is part of the project, then commission the system and check the airflow. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work: one team handles everything.

AirGreen is a family business established in Montreal for more than fifteen years. We work in Laval, Longueuil, on the North Shore and on the South Shore.

Let’s talk about your project

Sold alone, this fan coil does not qualify for the LogisVert grant: the grant applies to a certified pair. If you are considering replacing the whole system, we compare both options with you.

Ask for your free on-site estimate and receive a clear written quote. Financing is available to spread the cost of your project.

01 · What it is for

The indoor cabinet of a small R-410A central system

The FXM4X1800AL carries refrigerant from the outdoor unit through its aluminum coil and pushes conditioned air into the ductwork. It installs vertically or horizontally, which makes replacements easier in a basement, a closet or a service space.

  • Replacing a 1.5-ton R-410A air handler at the end of its life
  • Bungalows, condos and small houses that already have ductwork
  • Upflow or horizontal-left installation with no cabinet modification
  • Adding 5, 8 or 10 kW of electric backup heat with an EHK kit
Constant-torque X13 ECM motor1/3 HP motor with 5 taps: 319 to 776 CFM depending on the tap selected and the static pressure (dry coil).
Factory-installed TXVThe all-aluminum coil, tubes and fins, ships with its thermostatic expansion valve already mounted.
Arcoaire warranty5-year No Hassle replacement limited warranty and 5-year parts limited warranty, plus 5 more years on parts with timely registration (residential).
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerArcoaire
TypeMultiposition fan coil (air handler with coil)
Nominal size1.5 tons (18,000 BTU/h)
RefrigerantR-410A
Metering deviceFactory-installed TXV
CoilAluminum tubes and fins, 14-1/2 fins/in, slope coil
Nominal airflow600 CFM (283 L/s)
Airflow range319 to 776 CFM (tap 1 at 0.60 in w.c. to tap 5 at 0.10 in w.c., dry coil)
MotorConstant-torque ECM (X13), 1/3 HP, 5 taps, 2.8 A (FLA)
Power supply208/230 V, single phase, 60 Hz
MCA / max. overcurrent protection3.5 A / 15 A (fan coil only)
Liquid connection3/8 in (10 mm), sweat
Suction connection5/8 in (16 mm), sweat
Filter16-3/8 x 21-1/2 in (416 x 546 mm), washable, factory supplied
PositionsUpflow or horizontal left; horizontal right with minor modification; downflow with kit
Insulation1 in, R-4.2
DrainPrimary and secondary fittings with brass inserts
Dimensions (H x W x D)49-5/8 x 17-5/8 x 22-1/16 in (1,261 x 448 x 560 mm)
Shipping weight122 lb (55 kg)
Heater kitsEHK05AKN/AKB (5 kW), EHK07AKN/AKB (8 kW), EHK10AKN/AKB (10 kW), sold separately
Manufacturer warrantyArcoaire: 5-year No Hassle replacement limited; 5-year parts limited, plus 5 years with timely registration (residential)
Model numberFXM4X1800AL
03 · Before installing

What to know before installing

  • Available while supplies last.
  • Sold alone: not eligible for the LogisVert grant. The grant follows the certified outdoor unit + air handler pair.
  • The heating element is not included. For this size, Arcoaire lists the EHK05 (5 kW), EHK07 (8 kW) and EHK10 (10 kW) kits, sold separately; no 15 kW or larger kit is listed.
  • 208/230 V single-phase, 60 Hz power supply. For the fan coil alone: 3.5 A minimum circuit ampacity, 15 A maximum overcurrent protection. With a heater kit, follow the values on the rating plate.
  • Plan room for a 49-5/8 x 17-5/8 x 22-1/16 in cabinet (H x W x D), plus the service clearance the manufacturer requires.
  • Horizontal-right installation requires a minor modification; downflow requires a conversion kit sold separately.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces – air handlers
See all
Same brand
ARCOAIRE
See all
06 · Questions

Frequently asked questions

Is this model still available?

Yes, while supplies last. If the FXM4X1800AL is no longer available when your project starts, we propose a replacement air handler that is compatible with your outdoor unit.

Is electric heat included?

No. The fan coil has no heating element. For this size, Arcoaire lists the EHK05 (5 kW), EHK07 (8 kW) and EHK10 (10 kW) kits, sold separately.

Which outdoor unit does it work with?

The manufacturer’s data sheet does not name a specific outdoor unit for this model. It is a 1.5-ton R-410A cabinet: send us the model number of your heat pump or air conditioner and we check compatibility before ordering.

Does this air handler qualify for a grant?

Not when it is sold alone. Hydro-Québec’s LogisVert grant follows a certified outdoor unit + air handler pair. For a complete system, ask us for a quote.

What warranty does Arcoaire provide?

For this model, Arcoaire prints a 5-year No Hassle replacement limited warranty and a 5-year parts limited warranty, extended by 5 years on parts with timely registration, for residential use.

Can you install it?

Yes. Our technicians set the cabinet, connect it to the ductwork, the refrigerant line set and the power supply, then commission the system.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 1.5-ton Arcoaire fan coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom