BOSCH BVA M15 Electric Furnace | 2 Tons - 24000 BTU - R410A

In stock

Bosch’s 2-ton BVA-24WN1-M15 multiposition air handler: R-410A coil and 3-speed PSC motor, for the Bosch IDS 1.0 Plus heat pump platform.

Model numberBVA-24WN1-M15

1,107 SCFMairflow at high speed
2 tons24,000 BTU/h nominal size
55 dB(A)at low speed (62 dB(A) at high)
R-410A208/230 V · single phaseMultipositionOptional backup heat (EHK)
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberBVA-24WN1-M15
ManufacturerBosch
SeriesBVA 15 (IDS 1.0 Plus)
Size2 tons (24,000 BTU/h)
Airflow743 / 958 / 1,107 SCFM
MotorPSC, 3 speeds, 1/5 HP
Power supply208/230 V, 1 ph, 60 Hz

A Bosch air handler that goes where the house has room

What the BVA-24WN1-M15 is

The BVA-24WN1-M15 is the 2-ton (24,000 BTU/h) air handler of Bosch’s BVA 15 series. It combines the blower and the R-410A coil in one cabinet, and Bosch designs it for its BOVA M15-series inverter heat pump, on the IDS 1.0 Plus platform. Installed indoors, it distributes through the ducts the heat or cooling produced by the outdoor unit.

Bosch offers two 2-ton air handlers in this family: this one, with a PSC motor, and the BVA-24WN1-M18, with an ECM motor, available while supplies last. The PSC or ECM tag in the series selector tells them apart.

Its real strength: position

The cabinet ships in upflow or horizontal right position and converts on site to horizontal left or downflow. For a Québec home, that flexibility matters. In a Longueuil bungalow with no basement room, it can lie in a crawl space; in a Montreal condo, it stands upright in a closet. Allow 46-1/2 in of height, 19-5/8 in of width and 21-5/8 in of depth for the cabinet, plus the plenum.

The PSC motor offers three speeds: 743, 958 or 1,107 SCFM, with medium as the factory setting. Bosch publishes 62, 59 and 55 dB(A) depending on speed. The 18 x 20 in filter rack is integrated and opens without tools, which makes routine maintenance easier.

Electrical and backup heat

Without a heater kit, the air handler needs a 2 A minimum circuit ampacity and 15 A maximum overcurrent protection, at 208/230 V single phase, 60 Hz. For electric backup heat in extreme cold, Bosch lists three kits for this size: EHK-05B (5 kW), EHK-08B (7.5 kW) and EHK-10B (10 kW). The EHK-15B and EHK-20B are not available for size 24. The kit is sold separately; we choose it based on the house and the panel capacity.

The air handler is sold alone. The spec sheet does not name the exact outdoor model: we confirm the match before ordering. Sold alone, it does not qualify for the LogisVert grant, which follows the certified outdoor unit + air handler pair.

What the installation covers

AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. After a free on-site estimate and a written quote, our technicians choose the cabinet position, install it, connect it to the ducts, the refrigerant piping (3/8 in liquid, 3/4 in suction) and the condensate drain, fit the heater kit if planned, make the electrical connection and commission the system. We install in Laval, on the South Shore, on the North Shore and throughout Greater Montreal.

Let’s find it the right spot

Book your free estimate: we choose the position, the kit and the match, then you receive a written quote. Financing is available.

01 · What it is for

The indoor section of a Bosch central heat pump

The BVA-24WN1-M15 combines the blower and the R-410A coil in one cabinet. Bosch designs it for its BOVA M15-series inverter heat pump; it installs in upflow or horizontal position and can be completed with an EHK electric heater kit.

  • Completing a 2-ton Bosch IDS 1.0 Plus central heat pump
  • Installations in the basement, a closet or a crawl space in horizontal position
  • Single-storey houses and condos with ductwork
  • Projects adding 5, 7.5 or 10 kW of electric backup heat
MultipositionUpflow or horizontal right as shipped, field convertible to horizontal left or downflow.
Three selectable speeds743, 958 or 1,107 SCFM depending on speed; medium is the default setting.
62, 59 and 55 dB(A)The published sound levels at high, medium and low speed.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerBosch
SeriesBVA 15 (IDS 1.0 Plus)
TypeMultiposition air handler with coil, for a central heat pump
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-410A
Airflow (0.0 in. W.C.)743 / 958 / 1,107 SCFM (low / medium default / high)
MotorPSC, 3 selectable speeds, 1/5 HP
Sound level62 / 59 / 55 dB(A) (high / medium / low)
Power supply208/230 V, single phase, 60 Hz
Minimum circuit ampacity2 A (without heater kit)
Maximum overcurrent protection15 A (without heater kit)
Liquid connection3/8 in O.D.
Suction connection3/4 in O.D.
FilterIntegrated 18 x 20 in rack, tool-less door
PositionsUpflow or horizontal right as shipped; convertible to horizontal left or downflow
Heater kitsEHK-05B (5 kW), EHK-08B (7.5 kW), EHK-10B (10 kW); EHK-15B and EHK-20B not available for this size
Dimensions (H x W x D)46-1/2 x 19-5/8 x 21-5/8 in (1180 x 500 x 550 mm)
Weight126 lb net; 154 lb packaged
Model numberBVA-24WN1-M15
03 · Before installing

What to know before installing

  • Sold alone: not eligible for the LogisVert grant. The grant follows the certified outdoor unit + air handler pair.
  • The outdoor unit is not included, and the spec sheet does not name the exact outdoor model: we confirm the match before ordering.
  • Backup heat not included: EHK-05B (5 kW), EHK-08B (7.5 kW) or EHK-10B (10 kW) kits. EHK-15B and EHK-20B are not available for this size.
  • 2 A minimum circuit ampacity and 15 A maximum overcurrent protection for the air handler without a heater kit, at 208/230 V single phase, 60 Hz.
  • Plan room for a 46-1/2 x 19-5/8 x 21-5/8 in cabinet (H x W x D) weighing 126 lb, plus the service clearance the manufacturer requires.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces – air handlers
See all
Same brand
BOSCH
See all
06 · Questions

Frequently asked questions

Which outdoor unit does this air handler work with?

Bosch presents it as the air handler for its BOVA M15-series inverter heat pump (IDS 1.0 Plus platform). The spec sheet does not name the exact outdoor model: we confirm the match before ordering.

Which heater kit can be added?

For this size, Bosch lists the EHK-05B (5 kW), EHK-08B (7.5 kW) and EHK-10B (10 kW) kits. The EHK-15B and EHK-20B are not available for size 24. We choose the kit with you based on the house and the panel.

Can it be installed horizontally?

Yes. It ships in upflow or horizontal right position and converts on site to horizontal left or downflow.

Is it quiet?

Bosch publishes 62 dB(A) at high speed, 59 dB(A) at medium and 55 dB(A) at low. Perceived noise also depends on the ducts and grilles, which we check.

Does it qualify for a grant?

Not when sold alone. Hydro-Québec’s LogisVert grant follows a certified outdoor unit + air handler pair; for a complete system, we check eligibility in the quote.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton Bosch BVA air handler, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.