BOSCH BVA M18 Electric Furnace | 2 Tons - 24000 BTU - R410A

In stock

Bosch’s 2-ton BVA-24WN1-M18 air handler with a multi-speed ECM motor: the original BVA series, available while supplies last.

Model numberBVA-24WN1-M18

829 to 1,016SCFM depending on tap
2 tons24,000 BTU/h nominal size
ECM1/3 HP multi-speed motor
Available while supplies last208/230 V · single phase5-tap ECM motor
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberBVA-24WN1-M18
ManufacturerBosch
SeriesOriginal BVA (IDS 1.0)
Size2 tons (24,000 BTU/h)
MotorMulti-speed ECM, 1/3 HP, 5 taps
Airflow829 to 1,016 SCFM
Minimum circuit ampacity3.5 A

A Bosch air handler with an ECM motor, while it lasts

The BVA-24WN1-M18 in brief

The BVA-24WN1-M18 is the 2-ton (24,000 BTU/h) air handler of Bosch’s original BVA series, designed for the first Bosch IDS 1.0 heat pump platform. It is available while supplies last. Its distinguishing feature is its motor: a 1/3 HP multi-speed ECM with five speed taps.

For those five taps, Bosch publishes airflows of 1,016, 955, 927, 887 and 829 SCFM, measured at 0.0 in. W.C. In practice, the installer has several settings to match the airflow to the house and the ductwork, which helps keep the system quiet at the grilles.

Who this air handler makes sense for

The most natural case is replacement. If your home in Laval or on the North Shore has a Bosch IDS 1.0 system whose air handler needs replacing, finding a BVA from the same family keeps things simple. It also suits a new 2-ton project in a single-storey house or a Montreal condo that already has ducts, as long as stock allows.

If stock runs out, Bosch offers another 2-ton air handler in the BVA family: the BVA-24WN1-M15, with a three-speed PSC motor and the same published footprint. The two do not use the same heater kits.

Points to check

  • Electrical: 208/230 V single phase, 60 Hz; 3.5 A minimum circuit ampacity; 15 A maximum time-delay fuse or HACR breaker. The motor is rated at 2.8 A.
  • Space: a cabinet 46-1/2 in high, 19-5/8 in wide and 21-5/8 in deep, plus the plenum and service clearance.
  • Filter: 18 x 20 in size.
  • Backup heat: not included. It is added with a WEHK-series kit; the heat output allowed for size 24 is confirmed before ordering.

The air handler is sold alone, without an outdoor unit. It does not qualify for the LogisVert grant, which follows the certified outdoor unit + air handler pair; we confirm the match with the manufacturer before ordering.

Installation by AirGreen

AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. The on-site estimate is free and you receive a written quote. Our technicians remove the old air handler, install the BVA-24WN1-M18, connect it to the ducts, the refrigerant piping and the condensate drain, fit the WEHK kit if planned, choose the speed tap that suits your ducts and commission the system. We work in Longueuil, on the South Shore and throughout Greater Montreal.

Reserve it before it is gone

Book your free estimate: we confirm availability, the match and the heater kit, then you receive a written quote. Financing is available.

01 · What it is for

The ECM air handler of the first Bosch IDS platform

The BVA-24WN1-M18 is the 2-ton air handler of Bosch’s original BVA series, on the IDS 1.0 platform. Its multi-speed ECM motor offers five speed taps. It is available while supplies last.

  • Replacing a 2-ton original BVA air handler in a Bosch IDS 1.0 installation
  • Completing a 2-ton central system with an ECM-motor air handler
  • Single-storey houses and condos with ductwork
  • Projects planning electric backup heat with a WEHK kit
5-tap ECM motor1/3 HP multi-speed motor; Bosch publishes 829 to 1,016 SCFM depending on the tap, at 0.0 in. W.C.
3.5 A circuitPublished minimum ampacity, with a 15 A maximum time-delay fuse or HACR breaker.
18 x 20 in filterThe filter size Bosch publishes for this air handler.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerBosch
SeriesOriginal BVA (IDS 1.0)
TypeAir handler (blower cabinet) for a central system
Nominal size2 tons (24,000 BTU/h)
Airflow (0.0 in. W.C.)1,016 / 955 / 927 / 887 / 829 SCFM (5 taps)
MotorMulti-speed ECM, 1/3 HP, 5 speed taps
Motor full load amps (FLA)2.8 A
Power supply208/230 V, single phase, 60 Hz
Minimum circuit ampacity3.5 A
Maximum overcurrent protection15 A (time-delay fuse or HACR breaker)
Filter18 x 20 in
Heater kitsWEHK series, sold separately (WEHK05A, WEHK08A, WEHK10A, WEHK15B, WEHK20B)
Dimensions (H x W x D)46-1/2 x 19-5/8 x 21-5/8 in (1180 x 500 x 550 mm)
Model numberBVA-24WN1-M18
03 · Before installing

What to know before installing

  • Available while supplies last.
  • Sold alone: the LogisVert grant follows the certified outdoor unit + air handler pair; this air handler alone does not qualify.
  • The outdoor unit is not included: we confirm the match with the manufacturer before ordering.
  • Backup heat not included: it is added with a WEHK-series kit (WEHK05A to WEHK20B). The heat output allowed for size 24 cannot be read in the spec sheet consulted; we confirm it before ordering.
  • 208/230 V single-phase, 60 Hz power supply: 3.5 A minimum circuit ampacity, 15 A maximum time-delay fuse or HACR breaker.
  • Plan room for a 46-1/2 x 19-5/8 x 21-5/8 in cabinet (H x W x D), plus the service clearance the manufacturer requires.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces – air handlers
See all
Same brand
BOSCH
See all
06 · Questions

Frequently asked questions

Is this model still available?

It is available while supplies last; we confirm availability in the quote. If stock runs out, the BVA-24WN1-M15, with a PSC motor, is the other 2-ton Bosch air handler in the BVA family.

How does it differ from the BVA-24WN1-M15?

Both are 2-ton air handlers with the same published footprint, 46-1/2 x 19-5/8 x 21-5/8 in. The M18 has a 5-tap multi-speed ECM motor; the M15 has a 3-speed PSC motor. Their heater kits differ: WEHK for the M18, EHK for the M15.

Which heater kit can be added?

The M18 uses WEHK-series kits. The spec sheet consulted does not show reliably which heat outputs are allowed for size 24: we confirm it with the manufacturer before ordering.

What electrical circuit is needed?

Bosch publishes a 3.5 A minimum circuit ampacity and 15 A maximum protection, by time-delay fuse or HACR breaker, at 208/230 V single phase. A heater kit raises the load; we check the panel on site.

Does it qualify for the LogisVert grant?

Not when sold alone. The grant follows a certified outdoor unit + air handler pair. For a complete system, we check the proposed pair’s eligibility.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A Bosch BVA ECM air handler, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.