AMERISTAR 5MXCB004AC6HCA Evaporator A-Coil | 1.5 to 3 Tons

In stock

The Ameristar 5MXCB004AC6HCA 1.5 to 3-ton R-454B cased coil sits on your furnace and, matched with a matching Ameristar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model number5MXCB004AC6HCA

1.5 to 3 tons36,000 BTU/h nominal
17-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model number5MXCB004AC6HCA
ManufacturerAmeristar
Size1.5 to 3 tons
Width17-1/2 in
RefrigerantR-454B
MeteringPiston

5MXCB004AC6HCA coil: 17-1/2 in wide, 20 in high, for the mid-size furnace

A typical measuring visit, from start to finish

Picture a two-storey home on the South Shore with a gas or electric furnace in the basement, an old central air conditioner that is wheezing, and a family thinking about a heat pump. The AirGreen technician arrives with a tape measure, a flashlight and a list of questions. Before even talking about tons, he measures the width of the furnace cabinet. If it is 17-1/2 in, the Ameristar 5MXCB004AC6HCA evaporator coil comes straight into the discussion.

This cased coil from the 5MXC series covers the 1.5 to 3 ton size (36,000 BTU/h), uses R-454B refrigerant and mounts on the furnace to form a central system with an Ameristar outdoor unit. We work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

What sets it apart from its slimmer neighbour?

On paper, the 5MXCB004AC6HCA and the 5MXCA003AC6HCA offer the same nominal capacity. The difference is width: 17-1/2 in here, 14-1/2 in for its smaller sibling. This model's full size is 17-1/2 × 20 × 21 in, with a net weight of 46 lb.

In practice, this means it mounts directly on a mid-size furnace, without having to narrow or widen the plenum. It seems like a minor detail, but it saves hours of sheet-metal work and reduces the points where air can leak.

How a coil works, without the jargon

The outdoor unit sends liquid refrigerant indoors. Inside the coil tubes, that liquid evaporates and absorbs heat from the air passing through. The cooled air, relieved of some of its moisture, heads back into the ducts. The condensed moisture runs into the pan and leaves through the 3/4 in NPT drain connection.

The refrigerant travels through two copper lines: a 3/8 in liquid line connection and a 3/4 in suction line connection. These are the sizes our technicians braze on site.

The role of the piston

Every coil in the series has a piston-type metering device. It is a small calibrated orifice at the coil inlet that limits the flow of refrigerant. Unlike an adjustable valve, it does not move, so its performance depends on a good match with the outdoor unit and on a refrigerant charge carefully adjusted at start-up.

Adding a heat pump to an existing furnace

The "add-on" scenario appeals because it keeps most of your current equipment:

  • the blower, filters and existing ducts stay in use;
  • the outdoor unit is added beside the house;
  • the furnace takes over when the outdoor temperature drops below the threshold that we set with you.

If the outdoor unit is a plain air conditioner, you will only get cooling, but the coil will still be new and suited to the new refrigerant.

Permitted installation positions

The manufacturer describes this model as multi-position: upflow, downflow, horizontal left or right. In practice, the furnace in your basement determines the position. We always confirm the airflow direction and the access to the drain before fastening the cabinet.

The technical features at a glance

  • model: 5MXCB004AC6HCA, cased evaporator coil;
  • series: 5MXC;
  • nominal size: 1.5 to 3 tons (36,000 BTU/h);
  • refrigerant: R-454B;
  • dimensions (W × H × D): 17-1/2 × 20 × 21 in;
  • net weight: 46 lb;
  • connections: 3/8 in liquid, 3/4 in suction;
  • drain: 3/4 in NPT;
  • metering device: piston;
  • leak detection: "R454B Refrigerant Mitigation Sensor" and MCB kit shown on the dimensional drawing (COR-PSD013A-EN); function not described.

Which model in the series for which furnace?

To decide, here are the benchmarks taken from each model's data sheet:

  • 5MXCA003AC6HCA: 1.5 to 3 tons, 14-1/2 in. The one to choose for a small furnace.
  • 5MXCB004AC6HCA (this one): 1.5 to 3 tons, 17-1/2 in.
  • 5MXCB006AC6HCA: same 17-1/2 in width, but the size goes up to 3.5 tons.
  • 5MXCC005AC6HCA and 5MXCC007AC6HCA: 21 in wide, at 1.5 to 3 tons and 1.5 to 3.5 tons respectively.
  • 5MXCC009AC6HCA: 21 in, 3 to 5 tons.
  • 5MXCD008AC6HCA: 24-1/2 in, 3 to 3.5 tons.
  • 5MXCD010AC6HCA: 24-1/2 in, 3 to 5 tons.

If your furnace is 17-1/2 in wide and the need is around 3 tons or less, the 5MXCB004AC6HCA is the natural choice. If the assessment points to a heavier load, the 5MXCB006AC6HCA offers the same width with a larger size.

Pairing and ratings

This coil is paired with an Ameristar outdoor unit of the same capacity and the same refrigerant. The performance ratings (SEER2, EER2, HSPF2) are not those of the coil: they belong to the certified system identified by an AHRI number. We confirm that number before ordering. Ameristar lists AHRI-certified coils with Trane, American Standard, RunTru and Ameristar outdoor units (Trane COR-PSD013B-EN), with no published ENERGY STAR pairing under the 5MXC prefix.

How our installation goes

AirGreen has been a family-run heating and cooling company in Montreal for more than fifteen years, and our refrigeration, ventilation and electrical work falls under our RBQ licence 5645-9605-01. For this system:

  • measuring the furnace, checking the blower and the electrical panel;
  • setting the coil in the plenum, with an insulated transition if needed, then sealing the duct connections;
  • installing the outdoor unit, brazing the piping, nitrogen pressure test and evacuation;
  • connecting the condensate drain and the thermostat;
  • start-up, airflow adjustment and a walkthrough at the house.

Frequently asked questions

Can it heat? Yes, with a heat pump. With a central air conditioner, it only cools.

Can I keep my current air conditioner? Generally not. The coil runs on R-454B and must be paired with the outdoor unit specified by the manufacturer.

My furnace is not the right width. What can I do? We measure it and, if needed, build an insulated transition on site.

Who is this size best for?

The classic profile: a mid-size home, a mid-width furnace and an owner who wants to replace a tired air conditioner without turning the basement upside down. Families torn between window units and a central system will find a reasonable compromise here. The coil needs no plenum modification and no new duct system, if the furnace is the right width.

If, on the other hand, your furnace has already been replaced by a wider model, or if you plan to do so, let's talk about it at the visit: it is better to choose the coil for the equipment you will have tomorrow.

What to check before placing an order

  • R-454B requires an outdoor unit with the same refrigerant, installed at the same time.
  • The blower must be able to deliver the system's airflow.
  • The 17-1/2 in width must match the furnace.

Incentives and financing

Eligibility for Hydro-Québec programs depends on the complete system, not on the coil alone. We consult the official list when we prepare your quote, depending on the installation date.

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Ameristar system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The 5MXCB004AC6HCA sits in the plenum of a furnace or air handler. Connected to a matching Ameristar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Ameristar outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerAmeristar
Model5MXCB004AC6HCA
TypeCased evaporator coil
Line5MXC
Nominal size1.5 to 3 tons (36,000 BTU/h)
RefrigerantR-454B
Metering devicePiston
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D17-1/2 × 20 × 21 in
Net weight46 lb
Model number5MXCB004AC6HCA
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
AMERISTAR
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 1.5 to 3-ton Ameristar coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.