AMERISTAR 5MXCB006AC6HCA Evaporator A-Coil | 1.5 to 3.5 Tons

In stock

The Ameristar 5MXCB006AC6HCA 1.5 to 3.5-ton R-454B cased coil sits on your furnace and, matched with a matching Ameristar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model number5MXCB006AC6HCA

1.5 to 3.5 tons42,000 BTU/h nominal
17-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model number5MXCB006AC6HCA
ManufacturerAmeristar
Size1.5 to 3.5 tons
Width17-1/2 in
RefrigerantR-454B
MeteringPiston

5MXCB006AC6HCA coil: 26 in high and a size that climbs to 3.5 tons

What stands out first about the Ameristar 5MXCB006AC6HCA evaporator coil is its height: 26 in, which is clearly more than the two most compact models in the same series. That extra height holds a larger heat-exchange surface, and it is what lets the size extend from 1.5 to 3.5 tons (42,000 BTU/h). The width stays at 17-1/2 in, the depth at 21 in, and the net weight reaches 57 lb.

It runs on R-454B refrigerant and mounts on a furnace to form a central system with an Ameristar outdoor unit. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

Height: the point too often forgotten

When replacing a coil, people look at width, then capacity. Few think about the space above the furnace. Yet a 26 in tall cabinet adds height to the whole assembly. Between the top of the furnace and the basement ceiling, there has to be room for the cabinet, the supply plenum and service access.

During the visit, we measure that distance and look for beams, pipes and cables that could be in the way. In a low basement, a horizontal position can sometimes be used, which the manufacturer allows for this model just like the upflow and downflow positions.

Why a larger size needs more air

A higher-capacity coil cools a larger volume of air. For the system to deliver what its data sheet promises, the furnace blower has to push more airflow than a small size needs. So we check:

  • the capacity of the existing blower;
  • the size of the supply plenum;
  • the condition and sizing of the return ducts;
  • the filter, which has to let air through without choking it.

A coil that is too big for a weak blower can freeze up or leave the house uneven. The check is done before the order, not after.

Two-storey homes, bungalows and large townhouses

The 1.5 to 3.5 ton size is meant for homes where the ducts serve many rooms: two-storey houses, large bungalows, deep townhouses. It is a mid-range model that leaves some margin if you plan to expand, finish a basement or redo the insulation.

The piping: two possible suction line diameters

The liquid line connection is 3/8 in. For the suction line, the manufacturer's data sheet lists 3/4 in or 7/8 in, depending on the pairing. The diameter used depends on the outdoor unit chosen and on the length of piping between it and the furnace. We confirm this detail before cutting the copper. The condensate drain is 3/4 in NPT.

What the data sheet says

  • model: 5MXCB006AC6HCA, cased evaporator coil, 5MXC series;
  • nominal size: 1.5 to 3.5 tons (42,000 BTU/h);
  • refrigerant: R-454B;
  • dimensions (W × H × D): 17-1/2 × 26 × 21 in;
  • net weight: 57 lb;
  • liquid line connection: 3/8 in; suction line: 3/4 in or 7/8 in;
  • condensate drain: 3/4 in NPT;
  • metering device: piston;
  • positions: upflow, downflow, horizontal left or right;
  • leak detection: "R454B Refrigerant Mitigation Sensor" and MCB kit shown on the dimensional drawing (COR-PSD013A-EN); function not described.

This one or the 5MXCB004AC6HCA?

These two models have the same 17-1/2 in width. The 5MXCB004AC6HCA is limited to 1.5 to 3 tons, while this one goes up to 3.5. If your furnace suits both, the decision rests on your home's load, which the on-site assessment lets us calculate, and on the available height.

Here are the other models in the series, to put this one in context:

  • 5MXCA003AC6HCA: 14-1/2 in, 1.5 to 3 tons;
  • 5MXCC005AC6HCA: 21 in, 1.5 to 3 tons;
  • 5MXCC007AC6HCA: 21 in, 1.5 to 3.5 tons;
  • 5MXCC009AC6HCA: 21 in, 3 to 5 tons;
  • 5MXCD008AC6HCA: 24-1/2 in, 3 to 3.5 tons;
  • 5MXCD010AC6HCA: 24-1/2 in, 3 to 5 tons.

Heat pump or air conditioner?

Paired with a heat pump, the coil cools in summer and heats in winter through the same ducts. The furnace stays in place as backup heating for the coldest days, at a threshold that we set with you. Paired with a central air conditioner, it only cools. In both cases, the outdoor unit must use the same refrigerant as the coil.

The ratings belong to the system

The coil has no efficiency rating of its own. The SEER2, EER2 and HSPF2 ratings are tied to the certified system, identified by an AHRI number. Ameristar lists AHRI-certified coils with Trane, American Standard, RunTru and Ameristar outdoor units (Trane COR-PSD013B-EN), and no published ENERGY STAR pairing under the 5MXC prefix. We validate the pairing in the directory before ordering.

Our work on site

AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years; its refrigeration, ventilation and electrical work is covered by RBQ licence 5645-9605-01. On this taller model, the installation includes:

  • checking the available height, the blower and the electrical panel;
  • setting the cabinet, sealing the duct connections and, if needed, an insulated transition;
  • installing the outdoor unit, brazing the piping, nitrogen pressure test and evacuation;
  • the condensate drain, the thermostat and the airflow adjustment.

Points to confirm before buying

  • The outdoor unit must use R-454B and be installed along with the coil.
  • The 17-1/2 in width and the 26 in height must fit your furnace and your basement.
  • The blower must deliver the system's airflow.

Why height does not tell the whole story about comfort

A taller coil is not a guarantee of comfort in itself. What counts is the balance among three elements: the home's actual load, the airflow the blower can sustain and the quality of the duct system. If one of the three is weak, the other two cannot make up for it. We would rather spend an extra hour observing the house than promise a result that the duct system cannot deliver.

In North Shore and Laval homes built with long ducts under concrete floors, for example, the return air is often the weak point. An extra return grille or a larger-diameter duct can change comfort more than a bigger coil.

Maintenance after installation

A cased coil is simple to maintain: a clean filter, a clear drain and an annual check are enough to keep the system in good shape. We show you where the condensate drain is, how to recognize a clogged filter and when to call us. The pan must stay dry between cycles and the water must flow freely to the drain.

Incentives

Hydro-Québec programs assess the complete system, not the coil alone. We check the pairing against the official list when we prepare your quote and tell you what applies depending on the installation date.

Estimate and financing

Request your free on-site estimate: we measure the furnace and the available height, check the electrical service and give you a written quote for the complete Ameristar system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The 5MXCB006AC6HCA sits in the plenum of a furnace or air handler. Connected to a matching Ameristar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Ameristar outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerAmeristar
Model5MXCB006AC6HCA
TypeCased evaporator coil
Line5MXC
Nominal size1.5 to 3.5 tons (42,000 BTU/h)
RefrigerantR-454B
Metering devicePiston
Liquid connection3/8 in
Suction connection3/4 in or 7/8 in
Dimensions W × H × D17-1/2 × 26 × 21 in
Net weight57 lb
Model number5MXCB006AC6HCA
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
AMERISTAR
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 1.5 to 3.5-ton Ameristar coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.