AMERISTAR 5MXCD010AC6HCA Evaporator A-Coil | 3 to 5 Tons
The Ameristar 5MXCD010AC6HCA 3 to 5-ton R-454B cased coil sits on your furnace and, matched with a matching Ameristar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model number5MXCD010AC6HCA
514 316-2973 · sales@airgreen.ca
Quick facts
5MXCD010AC6HCA coil: the largest in the series, 24-1/2 in wide, 30 in high, 86 lb
Some models are chosen out of habit and others because no other one fits. The Ameristar 5MXCD010AC6HCA evaporator coil is one of the latter: it is the widest in the group, the same height as the 5MXCC009AC6HCA, with a cabinet of 24-1/2 × 30 × 21 in and a net weight of 86 lb. Its size covers 3 to 5 tons (60,000 BTU/h), the widest range toward the top of the series.
It runs on R-454B refrigerant and mounts on a large furnace or blower cabinet, paired with an Ameristar outdoor unit of the same capacity. AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
A portrait of the home that needs it
Think of a large North Shore residence: three storeys, a finished basement, a big south-facing window wall and a vast open space. Or a duplex where a single system serves the whole building. In these homes, the cooling load is high in summer, and the furnace in place is large. A lower-capacity coil would run endlessly without ever catching up with the afternoon heat.
The 5MXCD010AC6HCA is meant for those cases. It is not made for average homes: if the assessment gives a more modest load, a smaller model will be more relevant.
The logistics of an 86 lb cabinet
This is the heaviest in the series and it has to be treated as such. At delivery, we plan the access route, the width of the staircase and extra hands. On site, the cabinet rests on the furnace, and we check that the structure supports this additional load. The 30 in height calls for clearance above the furnace, which we measure before committing to anything.
The manufacturer allows upflow, downflow and horizontal (left or right) positions. When height is limited, horizontal may be the only solution.
5MXCD010AC6HCA specifications
- type: cased evaporator coil, 5MXC series;
- nominal size: 3 to 5 tons (60,000 BTU/h);
- refrigerant: R-454B;
- dimensions (W × H × D): 24-1/2 × 30 × 21 in;
- net weight: 86 lb;
- liquid line connection: 3/8 in;
- suction line connection: 3/4 in or 7/8 in;
- condensate drain: 3/4 in NPT;
- metering device: piston;
- leak detection: "R454B Refrigerant Mitigation Sensor" and MCB kit shown on the dimensional drawing (COR-PSD013A-EN); function not described.
Where it sits in the series
To understand the place of the 5MXCD010AC6HCA, let's compare it with its closest neighbours:
- 5MXCD008AC6HCA: same 24-1/2 in width, but 3 to 3.5 tons. The one to pick if the furnace is wide and the load moderate.
- 5MXCC009AC6HCA: same 3 to 5 ton range, but 21 in wide. The one to pick if the furnace is narrower.
- 5MXCC007AC6HCA and 5MXCC005AC6HCA: 21 in, 1.5 to 3.5 tons and 1.5 to 3 tons.
- 5MXCB006AC6HCA and 5MXCB004AC6HCA: 17-1/2 in, for mid-size furnaces.
- 5MXCA003AC6HCA: 14-1/2 in, 1.5 to 3 tons, for the smallest ones.
The 5MXCD010AC6HCA is therefore the only one to combine the maximum width of the series and the highest capacity range. If either of those conditions is missing, another model will fit better.
A system that heats too, on a large scale
Paired with a heat pump, this coil lets a large home heat with its own furnace as backup. The heat pump moves heat from outdoors to indoors; in mild weather, it delivers two to three times more heat than the electricity used. That efficiency drops with the cold, and the furnace takes over below a threshold that we set with you. With a central air conditioner, the coil only cools.
Electrical circuit and outdoor unit location
A system of this size draws more power. We check the electrical panel, the circuit rating and the location of the outdoor unit: level pad, clearance around the unit, shortest possible piping run. On the tight streets of Montreal and Longueuil, the available space often dictates the solution; on the North Shore and South Shore, we have more latitude, but the same rules apply.
Ratings and certified pairing
The coil does not display an efficiency rating of its own. The SEER2, EER2 and HSPF2 ratings belong to the certified system, linked by an AHRI number. Ameristar lists AHRI-certified coils with Trane, American Standard, RunTru and Ameristar outdoor units (Trane COR-PSD013B-EN), and no published ENERGY STAR pairing under the 5MXC prefix. We confirm the AHRI number before ordering.
Our installation
AirGreen has been a family-run heating and cooling company in Montreal for more than fifteen years, and holds RBQ licence 5645-9605-01 for its refrigeration, ventilation and electrical work. Installing a large coil includes measuring the furnace and the clearance, checking the blower and the panel, setting the cabinet, sealing the connections, installing the outdoor unit, brazing the piping, the nitrogen pressure test, the evacuation, the drain, the thermostat and the airflow adjustment. We finish with a full explanation of the system.
Maintaining a large coil
The bigger the coil, the more condensation water there is in summer. The 3/4 in NPT drain must stay clear, with a firm slope. We recommend an annual check, a regularly replaced filter and a look at the pan at the start of the hot season.
What to check before ordering
- The outdoor unit must use R-454B and be installed at the same time.
- The furnace must be 24-1/2 in wide and offer the 30 in height above it.
- The blower must deliver the system's airflow.
- The structure must support 86 lb.
What if a large home could get by with a smaller model?
This is the question we ask every time. A large home is not necessarily an energy-hungry one: good insulation, recent windows and well-oriented openings lower the cooling load. Sometimes the floor area is impressive while the calculation gives a modest result. In that case, the 5MXCD008AC6HCA, or a 21 in model, is better than oversizing the system.
Conversely, an older, poorly insulated home with large glazed areas facing south or west may call for the full range of the 5MXCD010AC6HCA. Only measurement settles it, and we do it on site.
Start-up and explanations
At the end of the work, we do not leave before checking the airflow, the condensate drainage and the thermostat's operation in both modes. We give you our team's contact details, explain how to change the filter and answer your questions, including those that come to you after we leave.
Incentives
Hydro-Québec programs assess the complete system, not the coil alone. We check the pairing against the official list when we prepare your quote and tell you what applies depending on the installation date.
Free estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Ameristar system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The 5MXCD010AC6HCA sits in the plenum of a furnace or air handler. Connected to a matching Ameristar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Ameristar outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 24-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
AMERISTARSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3 to 5-ton Ameristar coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.