AMERISTAR 5MXCC009AC6HCA Evaporator A-Coil | 3 to 5 Tons

In stock

The Ameristar 5MXCC009AC6HCA 3 to 5-ton R-454B cased coil sits on your furnace and, matched with a matching Ameristar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model number5MXCC009AC6HCA

3 to 5 tons60,000 BTU/h nominal
21 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model number5MXCC009AC6HCA
ManufacturerAmeristar
Size3 to 5 tons
Width21 in
RefrigerantR-454B
MeteringPiston

5MXCC009AC6HCA: the 3 to 5 ton coil for large homes, 21 in wide and 30 in high

When a home spreads over three levels, the kitchen opens onto a big living room and the upper floor gets sun all day, a small coil is no longer enough. The Ameristar 5MXCC009AC6HCA evaporator coil meets that need with a 3 to 5 ton size (60,000 BTU/h), a cabinet 21 in wide, 30 in high and 21 in deep, and a net weight of 82 lb.

It runs on R-454B refrigerant, mounts on a furnace or blower cabinet and is paired with an Ameristar outdoor unit of the same capacity. We work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

A heavy coil: what that changes at installation

At 82 lb, this is the first model in the series where handling becomes a real question. You do not carry it down a basement staircase alone. We plan for two technicians, a clear path and, when needed, a solid support under the cabinet. The 30 in height also calls for vertical clearance, which we measure at the visit, along with the plenum route and the access to the drain.

The manufacturer lists upflow, downflow and horizontal (left or right) positions. In a home with a low ceiling, the horizontal position can save the day.

Why a large home needs serious airflow

A 3 to 5 ton size moves a lot of air. If the furnace blower is undersized, or if the return ducts are too narrow, the coil performs poorly: air circulates badly, some rooms stay hot and the house feels unbalanced. That is why we always inspect:

  • the blower's power and its motor;
  • the supply plenum and its connections;
  • the return air paths, their number and their cross-section;
  • the electrical panel, which must accommodate a larger outdoor unit.

Piping and condensate

The liquid line connection is 3/8 in. The suction line can be 3/4 in or 7/8 in depending on the outdoor unit chosen and the length of the run. On a large coil that produces a lot of condensate, the 3/4 in NPT drain must have a firm slope and stay accessible for maintenance.

5MXCC009AC6HCA specifications

  • type: cased evaporator coil, 5MXC series;
  • nominal size: 3 to 5 tons (60,000 BTU/h);
  • refrigerant: R-454B;
  • dimensions (W × H × D): 21 × 30 × 21 in;
  • net weight: 82 lb;
  • connections: 3/8 in liquid, 3/4 in or 7/8 in suction;
  • condensate drain: 3/4 in NPT;
  • metering device: piston;
  • leak detection: "R454B Refrigerant Mitigation Sensor" and MCB kit shown on the dimensional drawing (COR-PSD013A-EN); function not described.

Compared with the other models in the series

The 5MXCC009AC6HCA is one of the two models that go up to 5 tons. The other is the 5MXCD010AC6HCA, which offers the same 3 to 5 ton range but at 24-1/2 in wide. The choice between the two depends on your furnace: 21 in here, 24-1/2 in there.

Lower on the scale:

  • 5MXCC007AC6HCA, 21 in, 1.5 to 3.5 tons;
  • 5MXCC005AC6HCA, 21 in, 1.5 to 3 tons;
  • 5MXCD008AC6HCA, 24-1/2 in, 3 to 3.5 tons;
  • 5MXCB006AC6HCA and 5MXCB004AC6HCA, 17-1/2 in;
  • 5MXCA003AC6HCA, 14-1/2 in.

If the assessment shows that your home does not need more than 3.5 tons, a smaller model will be the wiser choice: an oversized coil runs short cycles and dries the air poorly.

A heat pump on a large home

In a large home, the heat pump takes a significant share of the heating from fall to spring. The furnace stays there for the coldest days: it keeps its blower, its filters and its backup role, starting at a temperature threshold that we set with you. In summer, the same installation replaces a whole collection of window units with a single system that serves every floor.

The certified pairing

The coil has no efficiency rating of its own. The SEER2, EER2 and HSPF2 ratings are tied to the certified system, linked by an AHRI number. Ameristar lists AHRI-certified coils with Trane, American Standard, RunTru and Ameristar outdoor units (Trane COR-PSD013B-EN), and no published ENERGY STAR pairing under the 5MXC prefix. We check that number before ordering.

Our installation

AirGreen has been a family-run heating and cooling company in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. For a system of this size, we first check the furnace, the blower and the electrical service, then set the cabinet carefully, seal the duct connections, install the outdoor unit on its pad, braze the piping, pressure-test everything with nitrogen, pull a vacuum, connect the drain and the thermostat, and then adjust the airflow.

The question of the electrical panel and the outdoor location

A large outdoor unit needs a suitable circuit and a clear location: open air around it, a level pad, access for service and a reasonable distance from the coil to limit the length of piping. In the dense neighbourhoods of Montreal, Laval or Longueuil, where yards are narrow, we look for the location that respects the neighbours, the unit's ventilation and winter snow constraints.

On the North Shore and South Shore, where lots are often wider, the solution is simpler, but the panel check stays the same: we confirm the capacity of the electrical service before preparing the quote.

Maintaining a large coil

The bigger the coil, the more condensate it produces in summer. A clear drain and a clean pan are therefore essential. We advise having the whole assembly checked once a year, replacing the filter regularly and watching for any trace of water around the furnace. A simple check before the hot season avoids most unpleasant surprises.

An example on the North Shore

A North Shore couple is expanding their home: an addition on the ground floor, a finished basement and a large bay window. Their old air conditioner can no longer keep up. The furnace is 21 in wide. The load calculation exceeds the range of the two other models of that width, and the 5MXCC009AC6HCA becomes the only coherent choice, provided the blower and the return air paths keep up.

What to check before choosing

  • The outdoor unit must use R-454B and be installed at the same time.
  • The furnace must be 21 in wide, with the required height above it.
  • The blower must deliver the system's airflow.
  • The support must handle 82 lb.

Incentives

Hydro-Québec programs assess the complete system, not the coil alone. We check the pairing against the official list and tell you what applies depending on the installation date.

Estimate and financing

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Ameristar system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The 5MXCC009AC6HCA sits in the plenum of a furnace or air handler. Connected to a matching Ameristar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Ameristar outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerAmeristar
Model5MXCC009AC6HCA
TypeCased evaporator coil
Line5MXC
Nominal size3 to 5 tons (60,000 BTU/h)
RefrigerantR-454B
Metering devicePiston
Liquid connection3/8 in
Suction connection3/4 in or 7/8 in
Dimensions W × H × D21 × 30 × 21 in
Net weight82 lb
Model number5MXCC009AC6HCA
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 21 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
AMERISTAR
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3 to 5-ton Ameristar coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.