AMERISTAR 5MXCD008AC6HCA Evaporator A-Coil | 3 to 3.5 Tons
The Ameristar 5MXCD008AC6HCA 3 to 3.5-ton R-454B cased coil sits on your furnace and, matched with a matching Ameristar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model number5MXCD008AC6HCA
514 316-2973 · sales@airgreen.ca
Quick facts
5MXCD008AC6HCA: a large 24-1/2 in cabinet for a 3 to 3.5 ton load
The coil you choose because the furnace is wide
Some furnaces are wide without the house being enormous. You find them when an older high-airflow unit has been kept, or when a large blower cabinet serves a mid-size home. For those cases, the Ameristar 5MXCD008AC6HCA evaporator coil offers the 24-1/2 in width with a narrow capacity range, 3 to 3.5 tons (42,000 BTU/h).
Its dimensions are 24-1/2 in wide, 26 in high and 21 in deep, for a net weight of 64 lb. It runs on R-454B refrigerant and is paired with an Ameristar outdoor unit of the same capacity. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
A capacity range that starts higher
The narrower models in the series start at 1.5 tons. This one starts at 3 tons. That is an important difference: it is meant for homes whose cooling load already sits in the upper part of the usual residential scale, not for those torn between a small and a medium size. If your assessment points to a lighter load, a smaller model will be better suited.
Reading the data sheet numbers without getting lost
- model: 5MXCD008AC6HCA, cased evaporator coil, 5MXC series;
- nominal size: 3 to 3.5 tons (42,000 BTU/h);
- refrigerant: R-454B;
- dimensions (W × H × D): 24-1/2 × 26 × 21 in;
- net weight: 64 lb;
- liquid line connection: 3/8 in; suction line: 3/4 in or 7/8 in;
- condensate drain: 3/4 in NPT;
- metering device: piston;
- positions: upflow, downflow, horizontal left or right;
- leak detection: "R454B Refrigerant Mitigation Sensor" and MCB kit shown on the dimensional drawing (COR-PSD013A-EN); function not described.
Next to its twin, the 5MXCD010AC6HCA
These two models share the 24-1/2 in width, but they are the only ones in the series that reach this far in width. The 5MXCD010AC6HCA covers 3 to 5 tons; the 5MXCD008AC6HCA, 3 to 3.5 tons. Choosing the second means recognizing that the house does not need the large range and that the furnace dictates the width.
Here is the full picture for comparison:
- 14-1/2 in: 5MXCA003AC6HCA, 1.5 to 3 tons;
- 17-1/2 in: 5MXCB004AC6HCA (1.5 to 3 tons) and 5MXCB006AC6HCA (1.5 to 3.5 tons);
- 21 in: 5MXCC005AC6HCA, 5MXCC007AC6HCA and 5MXCC009AC6HCA (3 to 5 tons);
- 24-1/2 in: 5MXCD008AC6HCA (this one) and 5MXCD010AC6HCA.
In other words, if your furnace is 24-1/2 in and your need does not exceed 3.5 tons, this model avoids buying a coil bigger than necessary.
An alternative to the custom transition
When the furnace is wide and a narrower coil is installed, an insulated sheet-metal transition has to be built to connect the two. It is doable, but it adds joints and time. With a coil the same width as the cabinet, the air passes from one to the other without a detour, and there are fewer sealants to keep an eye on over time.
Airflow to check
Even though the capacity range is more modest than that of its big sibling, the system needs good airflow. We check the blower, the returns and the cross-section of the supply ducts. A cramped duct system gives long cycles and poorly served rooms, whatever coil is set on top.
Winter and summer
With a heat pump, the coil cools in summer and heats in winter. The furnace keeps its blower and filters, and serves as backup heating for the coldest days below a threshold that we set with you. With a central air conditioner, it only cools. In both cases, the outdoor unit must use the same refrigerant, R-454B.
Ratings and AHRI number
The coil has no efficiency rating of its own; the SEER2, EER2 and HSPF2 ratings are those of the certified system. Ameristar lists AHRI-certified coils with Trane, American Standard, RunTru and Ameristar outdoor units (Trane COR-PSD013B-EN), and no published ENERGY STAR pairing under the 5MXC prefix. We validate the AHRI number before ordering, so that the quote reflects what you will receive.
Our work at your home
AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is covered by RBQ licence 5645-9605-01. For this coil:
- we measure the furnace and check the blower and the electrical panel;
- we install the cabinet in the plenum and seal the duct connections;
- we set the outdoor unit, braze the piping, and run the nitrogen pressure test and evacuation;
- we connect the condensate drain and the thermostat;
- we adjust the airflow and explain how everything works.
Questions we are often asked
Can this coil heat? Yes, when paired with a heat pump. With a central air conditioner, it only cools.
Can I reuse my current outdoor unit? Generally not: the coil runs on R-454B and must be paired with the unit specified by the manufacturer.
Is the furnace still useful? Yes. It keeps its blower and serves as backup for the coldest days.
What to check before placing an order
- The outdoor unit must use R-454B and be installed at the same time.
- The furnace must be 24-1/2 in wide, or we build a transition.
- The blower must deliver the system's airflow.
An example of our reasoning during the visit
Take a South Shore home whose furnace, replaced a few years ago, has a wide cabinet. The owner wants air conditioning without touching the ducts. We measure the cabinet, find that it reaches 24-1/2 in, then calculate the home's load room by room: orientation, insulation, windows, number of occupants. If the result falls in the 3 to 3.5 ton range, the 5MXCD008AC6HCA is the logical candidate; if it exceeds that range, we move to the 5MXCD010AC6HCA.
At no point do we propose a model for the sole reason that it is in stock. The choice follows from the measurements, and we give you the details of our calculations with the written quote.
Maintenance and follow-up
A coil of this size asks for little attention: a clean filter, a clear drain and an annual check. We recommend checking the condensate drainage in spring and watching for any trace of water near the furnace. If an unusual noise or a drop in comfort appears, call us: an airflow adjustment is often enough to restore things.
Incentives
Hydro-Québec programs assess the complete system, not the coil alone. We check the pairing against the official list when we prepare your quote and tell you what applies, depending on the installation date.
Get your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Ameristar system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The 5MXCD008AC6HCA sits in the plenum of a furnace or air handler. Connected to a matching Ameristar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Ameristar outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 24-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
AMERISTARSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3 to 3.5-ton Ameristar coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.