COMFORTMAKER EVD5X38S17B Evaporator V-Coil | 3 Tons
The Comfortmaker EVD5X38S17B 3-ton R-454B cased coil sits on your furnace and, matched with a matching Comfortmaker outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEVD5X38S17B
514 316-2973 · sales@airgreen.ca
Quick facts
EVD5X38S17B: the entry point to the Comfortmaker range, 3 tons in a 17-1/2 in cabinet
Picture the typical bungalow in Longueuil or Laval: an electric furnace in the basement, a network of vents laid out decades ago and, in summer, two or three window air conditioners humming away. That is exactly the setting the Comfortmaker EVD5X38S17B evaporator coil is made for. It is a cased V-coil that runs on R-454B refrigerant and has a nominal size of 3 tons, or 36,000 BTU/h.
Mounted on the furnace, it becomes the cold exchanger of a central system. AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
What this coil does, in plain terms
Think of a radiator turned inside out: instead of heating the air, it cools it. The refrigerant arrives from the outdoor unit, evaporates inside the coil tubes and absorbs the heat from the air the blower pushes across them. The air comes out cooler and drier, and the water collected in the pan runs off to the drain.
Without this component, the outdoor unit cannot cool anything inside the house. That is why it is never chosen alone: it works as a pair with the unit installed in the yard.
The 3-ton size: a bungalow format
In the EVD5X series, this model is the smallest. It suits mid-sized single-storey homes, semi-detached houses and well-insulated cottages whose cooling load stays modest. A unit that is too big for its house runs in short bursts, shuts off too soon and leaves the air sticky; a well-matched size runs longer at a steady pace and dehumidifies better.
We do not pick the capacity by guesswork. During the visit, we look at the floor area, the insulation, the windows, the orientation and the condition of the ductwork before confirming or correcting the size.
The coil in an "add-on" heat pump
The word "add-on" describes a heat pump that is added to an existing furnace instead of replacing it. The furnace keeps its blower, its filters and its role as backup heat. The coil sits in the plenum, in the path of the air.
In winter, the cycle reverses: the outdoor unit draws heat from outside and delivers it to the air in the house. When the outdoor temperature drops below a threshold that we set with you, the furnace takes over. For a homeowner who heats with electricity, this is often the most direct route to a lower bill, because a heat pump moves heat instead of making it, and in mild temperatures it delivers two to three times more heat than the electricity it uses.
Shape, cabinet and connections
The two faces of the coil form a V inside an insulated cabinet. The manufacturer lists a vertical installation, with upflow or downflow airflow. Because it comes in a cabinet, it sits directly on the furnace, which speeds up the work and improves air tightness.
The connections deserve a closer look: 3/8 in for the liquid line and 3/4 in for the suction line. Of the eleven models in the series, this is the only one with a smaller suction line: all the others have a larger suction pipe. The metering device is a TXV, a valve that adjusts the refrigerant to the coil's demand. The condensate pan is made of PBT, sloped, with three sealed plugs.
A 17-1/2 in width: the measurement that decides
At 17-1/2 in, this coil is the narrowest in the family, a width it shares with just one other 3.5-ton model. Many compact furnaces in suburban homes are this width, which avoids improvising. If your furnace is wider, we build an insulated transition on site; we measure it during the visit, not after the order.
Summer in a bungalow: what really changes
On the first hot morning after the installation, you feel the difference throughout the house, not just in the room where the window air conditioner used to be. The cool air travels through the existing vents into the bedrooms, and the house loses its sticky July humidity. No more window blocked by a unit, no more compressor noise at the foot of the bed, no more seasonal storage in the shed.
A single thermostat controls everything. You set one temperature instead of juggling three remotes, and the same equipment serves in winter if the outdoor unit is a heat pump.
Matching with the outdoor unit
The coil accepts a Comfortmaker outdoor unit of the same capacity and the same refrigerant. Before placing an order, we look up the match in the AHRI directory and note its number. The efficiency ratings belong to that certified assembly, not to the coil taken on its own.
One detail that Comfortmaker points out: serial numbers with a B, such as EVD5X..S..B, are not yet listed in ENERGY STAR; only serial numbers with an A, of the EVD5X..M..A type, are certified there with the Q5H9V and N5H9V heat pumps. For approved matches, the AHRI directory remains the reference.
Choosing between the 3-ton and its neighbours in the series
- EVD5X38S17B (this one): 3 tons, 17-1/2 in, 3/4 in suction line.
- EVD5X42S17B: the same 17-1/2 in width, but 3.5 tons and a larger suction pipe. It fits if the house needs a little more capacity without changing the furnace size.
- EVD5X42S21B and EVD5X42S24B: also 3.5 tons, at 21 in and 24-1/2 in wide.
- The 4-ton and 5-ton models (21 in or 24-1/2 in) are meant for much larger homes.
All share the R-454B, the TXV metering device and the cabinet. The choice therefore comes down to two criteria: the capacity the house calls for and the width of your furnace.
EVD5X38S17B spec sheet
- type: cased evaporator coil, EVD5X series;
- nominal size: 3 tons (36,000 BTU/h);
- refrigerant: R-454B;
- width: 17-1/2 in;
- connections: 3/8 in liquid, 3/4 in suction;
- metering device: TXV;
- positions: vertical, upflow or downflow;
- condensate drain: sloped PBT pan, three sealed plugs;
- leak detection: factory-installed A2L sensor, no mitigation board, so a furnace with built-in mitigation or the ACAENCDIS01A kit is required;
- warranty: 10-year limited warranty on parts with registration within 90 days of installation, 5 years without registration.
What we do on installation day
- measuring the furnace, checking the blower and the electrical panel;
- installing the coil in the plenum, adding a transition if needed, sealing the joints;
- outdoor unit on a pad or bracket, brazed piping, nitrogen leak test, vacuum;
- connecting the drain and the thermostat;
- commissioning, airflow adjustment and a walk-through at your home.
The work is done under AirGreen's RBQ licence 5645-9605-01. AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years.
Before you sign
- R-454B requires an outdoor unit with the same refrigerant, installed at the same time.
- The published ratings apply to the certified match, not to a mix of parts.
- The furnace must offer the right width and airflow; the visit confirms it.
- A coil with an A2L detector and no mitigation board calls for an equipped furnace or the kit mentioned above.
Hydro-Québec incentives
Eligibility for Hydro-Québec programs depends on the complete system, not on the coil alone. We check the official list at the time of the quote, based on the installation date, and we tell you what applies to your project.
Have your furnace measured
Request a free in-home estimate: we take the measurements, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing lets you spread out the cost of the project.
The heat pump coil for your furnace
The EVD5X38S17B sits in the plenum of a furnace or air handler. Connected to a matching Comfortmaker outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Comfortmaker outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.