The Comfortmaker EVD5X42S17B 3.5-ton R-454B cased coil sits on your furnace and, matched with a matching Comfortmaker outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberEVD5X42S17B

3.5 tons42,000 BTU/h nominal
17-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberEVD5X42S17B
ManufacturerComfortmaker
Size3.5 tons
Width17-1/2 in
RefrigerantR-454B
MeteringTXV

The EVD5X42S17B, or how to fit 3.5 tons into a narrow furnace

Some homes need a little more capacity than a 3-ton system, but their furnace is nothing imposing. That is the situation the Comfortmaker EVD5X42S17B evaporator coil solves: a nominal size of 3.5 tons (42,000 BTU/h) in a cabinet only 17-1/2 in wide, with R-454B refrigerant.

This page answers the questions homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore most often ask before choosing this model.

What is an evaporator coil for?

It is the part where the air in the house meets the cold. The refrigerant, sent by the outdoor unit, circulates through finned tubes; the warm air passing through gives up its heat and its moisture. Nothing else in your system directly cools the air you breathe.

Here, the tubes are folded into a V inside an insulated cabinet. This shape provides a large exchange surface in a compact volume, which makes it attractive in a modest-sized furnace.

Why 3.5 tons rather than 3?

A half size more is the right move when the house has been enlarged, when a sunroom has been added or when afternoon sun exposure pushes a 3-ton unit to its limits. We always check this with a simple load calculation during the visit: floor area, insulation, windows, number of occupants.

That said, bigger is not always better. If your house gets by with the 3-ton, the EVD5X38S17B, which has the same width, is the logical choice. We will tell you so frankly.

A system that also heats, if the outdoor unit is a heat pump

The coil handles air conditioning in every case. With a matched heat pump, it also works in winter: the refrigerant warmed outside gives up its heat to the air passing through the cabinet. The furnace stays in place with its blower and filters, and takes over when the outdoor temperature falls below the threshold we set with you.

With a simple central air conditioner, on the other hand, the coil only does the cooling.

How the coil is installed

It is installed vertically, with upflow or downflow airflow, on top of the furnace or beneath it. Since it is already in its insulated cabinet, there is no box to build: we mount it, seal the joints and connect the piping. The liquid connection is 3/8 in and the suction connection is 7/8 in.

The TXV metering device adjusts the refrigerant to the load. The condensate pan, made of PBT and sloped, empties the water toward the drain thanks to three sealed plugs that adapt to the position of the pipe.

Is my furnace the right width?

The coil measures 17-1/2 in. If your furnace is the same width, the installation goes in a straight line. If not, we build an insulated transition on site, after measuring at your home. This step is part of the estimate visit; nothing is ordered before we have checked.

The blower matters as much as the width. A 3.5-ton size needs more air than a 3-ton, and a blower that is too tight reduces comfort. We check its airflow, the size of the plenum and the condition of the return air.

The comfort you notice in practice

A well-sized system starts its cooling, reaches the requested temperature and holds that level without abrupt cycling. The house cools evenly, and the air loses its moisture as it passes over the cold tubes. Occupants mostly notice two things: a less stuffy upper floor and easier nights.

The 3.5-ton capacity also serves homes where the air distribution is generous, with several vents per floor. In a small house with a limited duct network, it would be pointless, because the air has nowhere to go; that is why we talk about airflow before we talk about tonnage.

Which outdoor unit should you choose?

A Comfortmaker unit of the same capacity and the same refrigerant. The exact match goes through the AHRI directory, where we note the number of the certified system before ordering. That number is what ties efficiency ratings to the coil-plus-outdoor-unit assembly.

A clarification from Comfortmaker: serial numbers with a B (EVD5X..S..B) are not yet listed in ENERGY STAR, while serial numbers with an A (EVD5X..M..A) are certified there with the Q5H9V and N5H9V heat pumps. The AHRI directory lists the approved matches.

EVD5X42S17B, EVD5X42S21B or EVD5X42S24B?

These three models offer the same 3.5-ton capacity, the same R-454B and the same TXV metering device. Only the width changes:

  • 17-1/2 in: the EVD5X42S17B, for narrow furnaces;
  • 21 in: the EVD5X42S21B, for mid-width furnaces;
  • 24-1/2 in: the EVD5X42S24B, for large furnaces.

The right model is the one whose width fits your equipment. Between this model and the EVD5X38S17B, the width is identical; only the capacity, 3 tons against 3.5, separates them.

EVD5X42S17B features

  • type: cased evaporator coil, EVD5X series;
  • size: 3.5 tons (42,000 BTU/h);
  • refrigerant: R-454B;
  • width: 17-1/2 in;
  • connections: 3/8 in liquid, 7/8 in suction;
  • metering device: TXV;
  • drain: sloped PBT pan, three sealed plugs;
  • leak detection: factory A2L sensor with no mitigation board, which requires a furnace with built-in mitigation or the ACAENCDIS01A kit;
  • 10-year limited warranty on parts with registration within 90 days after installation, 5 years without registration.

What AirGreen's installation includes

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 for its refrigeration, ventilation and electrical work. For this coil, the job covers:

  • measuring the furnace and checking the electrical panel;
  • installing the coil in the plenum and sealing the air connections;
  • the outdoor unit on a bracket, brazed piping, the nitrogen test and the vacuum;
  • the condensate drain and the thermostat;
  • start-up, airflow adjustment and a full demonstration.

Replacing an old central air conditioner

If your home already has a central air conditioner, the temptation is to change only the outdoor unit. With this coil, that is not possible: it runs on R-454B and must be matched with the unit specified by the manufacturer. An old coil and an old unit using a different refrigerant do not mix with this system.

The upside: a complete replacement, coil and unit together, brings back a manufacturer's warranty on parts and a system in which every element was chosen to work with the others. We keep the furnace, its filters and its air network as they are, unless the visit reveals a defect that needs correcting.

Points to confirm before ordering

  • The same refrigerant, R-454B, for the coil and the outdoor unit, installed together.
  • Published ratings that apply to the certified system, not to mismatched parts.
  • A furnace of the right width with a blower that delivers the system's airflow.

Financial assistance

Hydro-Québec programs apply to the complete system. We check the official list based on the installation date and tell you in the quote what applies to your project.

Let's look at your home's numbers

Request your free on-site estimate. We measure the furnace, assess the electrical service and write up a quote for the complete Comfortmaker system. Financing is available to spread out the cost.

01 · What it is for

The heat pump coil for your furnace

The EVD5X42S17B sits in the plenum of a furnace or air handler. Connected to a matching Comfortmaker outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Comfortmaker outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerComfortmaker
ModelEVD5X42S17B
TypeCased evaporator coil
LineEVD5X
Nominal size3.5 tons (42,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D17-1/2 in
Model numberEVD5X42S17B
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
COMFORTMAKER
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3.5-ton Comfortmaker coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.