COMFORTMAKER EVD5X61S24B Evaporator V-Coil | 5 Tons

In stock

The Comfortmaker EVD5X61S24B 5-ton R-454B cased coil sits on your furnace and, matched with a matching Comfortmaker outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberEVD5X61S24B

5 tons60,000 BTU/h nominal
24-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberEVD5X61S24B
ManufacturerComfortmaker
Size5 tons
Width24-1/2 in
RefrigerantR-454B
MeteringTXV

EVD5X61S24B: 5 tons and 24-1/2 in, what you need to know about A2L leak detection and the warranty

New-generation refrigerants change the way a coil is chosen a little. The Comfortmaker EVD5X61S24B is a good example: a cased V-shaped evaporator coil, rated at a nominal 5 tons (60,000 BTU/h), 24-1/2 in wide, that runs on R-454B refrigerant and includes an A2L leak sensor. This page dwells on those points, often poorly explained, for homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore.

The A2L sensor, in two sentences

The coil is delivered with a factory-installed leak detection sensor. It does not, however, come with a mitigation board: the furnace must therefore have built-in mitigation, or receive the ACAENCDIS01A kit.

That does not make the system complicated to live with. It simply means that we check the furnace before ordering, and add the kit to the quote if needed.

Why this check is done during the visit

A recent furnace may already include what is needed; an older one may not. We look at the nameplate, the condition of the control board and the compatibility with the sensor. This check, like measuring the plenum and the blower, is part of the free estimate.

The manufacturer's warranty, with no grey area

The limited warranty covers parts for 10 years if you register the product within 90 days of installation. Without registration, the term is 5 years. The condition is simple, but easy to forget: we remind you of the deadline at commissioning and we can help you with the process.

What the sensor changes for maintenance

For you, day to day, almost nothing: the sensor works in silence. For the technician, it offers an additional checkpoint during maintenance. We test it at commissioning and note it in the system's file, so that a future technician knows right away what was installed and how the furnace handles mitigation.

If you sell the house, this file is an asset: it describes the model numbers, the certified match and the installation date, which reassures an informed buyer.

A width designed for generous cabinets

At 24-1/2 in, this coil is made for a wide furnace. A narrower furnace calls for an insulated transition that we build on site; a furnace of the right width allows a direct installation, simpler and more airtight.

Five tons: the large size

This size is for large multi-level homes and additions. It calls for a blower able to deliver a large airflow and an electrical panel that accommodates the outdoor unit's circuit. We check both points, and we frankly acknowledge when a smaller size would suit the house better.

When the twin comes under another number

The EVD5X61S24B and the EVD5X60S24B share the same published spec sheet. Rather than pretend there is a difference, we rely on the approved match in the AHRI directory for your outdoor unit: the model number listed there is the one we order, install and write on your invoice. That way you avoid any ambiguity if, one day, a technician has to order a replacement part or check eligibility for a program.

The add-on system and the furnace's role

In an add-on system, the furnace stays in place with its blower, its filters and its heating elements. The coil is added in the plenum. In summer, the refrigerant evaporates in its tubes and captures the heat from the air; in winter, with a heat pump, the cycle reverses and the coil gives heat to the air in the house. The furnace takes over when the outdoor temperature drops below the threshold that we set with you.

Where this model sits in the series

  • EVD5X60S24B: identical spec sheet, meaning 5 tons, 24-1/2 in, R-454B, TXV;
  • EVD5X60S21B and EVD5X61S21B: 5 tons in 21 in;
  • EVD5X48S24B and EVD5X49S24B: 4 tons in 24-1/2 in;
  • EVD5X42S24B: 3.5 tons in 24-1/2 in.

The R-454B refrigerant, the TXV metering device and the cabinet are common to all. Capacity and width guide the choice.

Matching, AHRI and ENERGY STAR

The coil is paired with a Comfortmaker outdoor unit of the same capacity and the same refrigerant. The efficiency ratings belong to the certified system, linked by an AHRI number that we check in the directory before ordering. Serial numbers with a B (EVD5X..S..B) are not yet listed in ENERGY STAR; only serial numbers with an A (EVD5X..M..A) are certified there with the Comfortmaker Q5H9V and N5H9V heat pumps.

EVD5X61S24B spec sheet

  • type: cased evaporator coil, EVD5X series;
  • nominal size: 5 tons (60,000 BTU/h);
  • refrigerant: R-454B;
  • width: 24-1/2 in;
  • connections: 3/8 in liquid, 7/8 in suction;
  • metering device: TXV;
  • positions: vertical, upflow or downflow;
  • drain: sloped PBT pan, three sealed plugs;
  • leak detection: factory-installed A2L sensor, no mitigation board.

The installation at your home

AirGreen is a family-owned heating and cooling company in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. We measure the furnace, check the blower and the panel, install the coil, set up the outdoor unit, braze the piping, run the nitrogen test and the vacuum, connect the drain and the thermostat, then adjust the airflow and explain how it works.

A large-house project, carried out without surprises

The bigger the house, the more the details count: the route of the copper pipes between the outdoor unit and the furnace, the position of the unit relative to the windows, the layout of the condensate drain, the path of the wiring. We discuss each of these points with you during the visit and describe them in the written quote, so that installation day goes as planned and the house quickly returns to normal.

Checklist before buying

  • The same refrigerant, R-454B, for the coil and the outdoor unit.
  • Ratings valid for the certified match.
  • Width, blower and detector mitigation confirmed for your furnace.

Incentives

Hydro-Québec assesses the complete system, not the coil alone. We check the official list based on the installation date and tell you what applies to your project.

Getting your quote

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing lets you spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The EVD5X61S24B sits in the plenum of a furnace or air handler. Connected to a matching Comfortmaker outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Comfortmaker outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerComfortmaker
ModelEVD5X61S24B
TypeCased evaporator coil
LineEVD5X
Nominal size5 tons (60,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D24-1/2 in
Model numberEVD5X61S24B
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 24-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
COMFORTMAKER
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 5-ton Comfortmaker coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.