COMFORTMAKER EVD5X60S21B Evaporator V-Coil | 5 Tons

In stock

The Comfortmaker EVD5X60S21B 5-ton R-454B cased coil sits on your furnace and, matched with a matching Comfortmaker outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberEVD5X60S21B

5 tons60,000 BTU/h nominal
21 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberEVD5X60S21B
ManufacturerComfortmaker
Size5 tons
Width21 in
RefrigerantR-454B
MeteringTXV

EVD5X60S21B: 5 tons, the top of the series, in a 21 in cabinet

At the top of Comfortmaker's EVD5X range, you find the 5-ton coils. The EVD5X60S21B is one of them: a cased V-shaped evaporator coil, rated at a nominal 60,000 BTU/h, 21 in wide, that runs on R-454B refrigerant. It is meant for the largest homes in Montreal, Laval, Longueuil, the North Shore and the South Shore.

Before telling you why it may be suitable, let's talk about what has to be true in your home for a 5-ton system to be the right choice.

A capacity that has to be earned

We sometimes refuse to sell a 5-ton system. This size assumes a large house, often enlarged over the years, with a finished basement and several zones to cool. In a more modest house, it is pointless: it reaches the setpoint too quickly, shuts off and lets humidity settle in.

If, after measuring, we find that a 4-ton or 3.5-ton size meets the need, we tell you frankly. Sometimes two smaller systems, one per zone, serve the house better than a single big one.

The two checkpoints: electricity and air

At this capacity, two things are checked first. The first is the electrical service: the outdoor unit of a 5-ton system needs a dedicated circuit, and the panel must be able to accommodate it. The second is the air distribution: the furnace blower, the plenum and the returns must reach the airflow the system requires. If just one of these two falters, the promised comfort does not arrive.

The profile of a 5-ton house

Picture a large North Shore property: an open main floor, an upper floor with four bedrooms, a finished basement used as a playroom. South-facing picture windows, a sunroom added a few years ago. In summer, the upper floor heats up, the basement stays cool, and the old central air conditioner runs nonstop without catching up with the heat.

That is the setting where this coil makes sense. But even there, we measure, because enlarging a house changes its load, and a duct network designed for the original house is not always up to the current one.

What 21 in means for a 5-ton coil

The 21 in cabinet suits mid-width furnaces. Its twin of the same capacity, the EVD5X60S24B, measures 24-1/2 in. Between the two, the decision comes down to your furnace's cabinet: if it is about 21 in, the installation is direct; if it is narrower, we build an insulated transition on site; if it is wider, the 24-1/2 in model is better suited.

Another model, the EVD5X61S21B, shares the same published features: 5 tons, 21 in, R-454B, TXV. We work out with you which of the two model numbers matches the approved pairing.

Shape, cabinet and drain

The coil is V-shaped, delivered in an insulated cabinet, with a sloped PBT condensate pan and three sealed plugs. It is installed vertically, with upflow or downflow airflow. The metering device is a TXV. The connections are 3/8 in for the liquid and 7/8 in for the suction.

The coil in an add-on system

On a large electrically heated house, the idea of an add-on heat pump is quickly understood: the furnace stays, with its blower, its filters and its heating elements, and the heat pump becomes the main heating in mild weather. The coil adds air conditioning in summer. When the outdoor temperature drops below the threshold we program with you, the furnace takes over.

The bigger the house, the more this division of roles counts on the bill, since in mild temperatures a heat pump delivers two to three times more heat than the electricity it consumes.

Everyday comfort

When capacity and airflow are well matched, the rooms balance out: the upper floor no longer turns into an oven, the basement stops being icy, and the air loses the humidity that makes summer unpleasant. A single thermostat replaces the collection of window units, and the outdoor noise is concentrated in one place, the unit installed in the yard, which we place away from bedroom windows when possible.

Matching and AHRI number

The coil has no efficiency rating on its own. Its pairing with a Comfortmaker outdoor unit of the same capacity and the same refrigerant forms a certified system, with an AHRI number. We look it up in the directory before ordering, because that number is what counts when comparing quotes.

Comfortmaker points out that serial numbers with a B (EVD5X..S..B) are not yet in ENERGY STAR; only serial numbers with an A (EVD5X..M..A) are certified there with the Q5H9V and N5H9V heat pumps.

Where it sits in the series

  • EVD5X60S21B (this model): 5 tons, 21 in;
  • EVD5X61S21B: identical spec sheet, 5 tons, 21 in;
  • EVD5X60S24B and EVD5X61S24B: 5 tons, 24-1/2 in;
  • EVD5X48S21B: 4 tons, 21 in, for a slightly smaller house;
  • EVD5X42S21B: 3.5 tons, 21 in.

EVD5X60S21B spec sheet

  • type: cased evaporator coil, EVD5X series;
  • nominal size: 5 tons (60,000 BTU/h);
  • refrigerant: R-454B;
  • width: 21 in;
  • metering device: TXV;
  • leak detection: factory-installed A2L sensor, no mitigation board; furnace with built-in mitigation or ACAENCDIS01A kit required;
  • warranty: 10-year limited warranty on parts with registration within 90 days of installation, 5 years without registration.

The AirGreen installation

A family-owned heating and cooling company in Montreal for more than fifteen years, AirGreen works under RBQ licence 5645-9605-01. We:

  • measure the furnace and check the blower and the electrical panel;
  • install the coil in the plenum and seal the joints;
  • install the outdoor unit, braze the piping, run the nitrogen test and pull the vacuum;
  • connect the drain and the thermostat;
  • adjust the airflow and explain how it works at commissioning.

Before choosing a 5-ton system

  • R-454B is the refrigerant of the coil and of the outdoor unit, which are installed together.
  • The published ratings apply to the certified match.
  • The furnace has the right width, a sufficient blower, and the electrical panel can accommodate the circuit.

Hydro-Québec incentives

Eligibility depends on the complete system. We check the official list based on the installation date and tell you what applies.

Your estimate, with no obligation

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing lets you spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The EVD5X60S21B sits in the plenum of a furnace or air handler. Connected to a matching Comfortmaker outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Comfortmaker outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerComfortmaker
ModelEVD5X60S21B
TypeCased evaporator coil
LineEVD5X
Nominal size5 tons (60,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D21 in
Model numberEVD5X60S21B
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 21 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
COMFORTMAKER
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 5-ton Comfortmaker coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.