COMFORTMAKER EVD5X42S21B Evaporator V-Coil | 3.5 Tons

In stock

The Comfortmaker EVD5X42S21B 3.5-ton R-454B cased coil sits on your furnace and, matched with a matching Comfortmaker outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberEVD5X42S21B

3.5 tons42,000 BTU/h nominal
21 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberEVD5X42S21B
ManufacturerComfortmaker
Size3.5 tons
Width21 in
RefrigerantR-454B
MeteringTXV

EVD5X42S21B: 3.5 tons, 21 in wide, the middle size of the series

On paper, three 3.5-ton Comfortmaker coils look alike. In your basement, they are very different, because what matters is the metal box they sit on. The Comfortmaker EVD5X42S21B evaporator coil is 21 in wide: it sits in the middle between the narrow 17-1/2 in version and the wide 24-1/2 in version. Nominal size of 3.5 tons, or 42,000 BTU/h, with R-454B refrigerant.

We install it for homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore.

Start with the furnace, not the catalogue

Many people choose a capacity first, then look for a coil. We work the other way around. A tape measure, the furnace's nameplate, a look at the plenum: that is what determines the width. Once the width is known, two or three models remain to be sorted out by capacity.

The EVD5X42S21B is the right candidate when the furnace is 21 in wide, or close to it, so that a simple transition is enough to connect the two.

What the V shape brings

Two faces of tubes arranged in a V share the cabinet. The air passes through them, flowing around them over their whole surface, and the condensation water runs down to the pan instead of staying trapped in the fins. The insulated cabinet prevents losses and limits condensation on the outside of the plenum.

The installation is vertical, with upflow or downflow airflow, depending on where the blower is: the manufacturer lists no other position.

An add-on system, step by step

  1. The outdoor unit compresses the refrigerant and sends it to the coil.
  2. The TXV metering device controls how much refrigerant enters the tubes.
  3. The refrigerant evaporates, absorbs heat from the air and returns to the outdoor unit to start again.
  4. The furnace blower distributes the cooled air through the existing ducts.
  5. With a heat pump, the direction of the cycle reverses in winter and the same coil warms the air.

The furnace keeps its backup role: it takes over when the outdoor temperature drops below the threshold we set with you.

3.5-ton capacity: who is it for?

Cottages, somewhat large single-storey homes and well-insulated two-storey houses. The more rooms the duct network serves, the greater the airflow required, and the more the furnace blower has to measure up. We measure it, along with the plenum and the returns, before confirming the size.

A drier house, not just a cooler one

Summer comfort depends as much on humidity as on temperature. Air at the same temperature but loaded with water feels heavy, sticks to the skin and encourages a musty smell in the basement. As it passes through the cold tubes, the air sheds part of its water vapour, which condenses in the pan and then flows out through the drain. That is why a well-sized central air conditioning system changes the feel of Montreal summers far more than window units that serve only one room.

A system that is too big would do the opposite: it would shut off before it had time to dry the air. The load calculation done during the visit is there to avoid this trap, which is why it is important not to choose the capacity out of habit alone.

Matching and efficiency ratings

The coil has no rating of its own. The published ratings belong to the certified system, the one that pairs this coil with a Comfortmaker outdoor unit of the same capacity and the same refrigerant. We find that system in the AHRI directory, with its number, before ordering.

A note from the manufacturer: serial numbers with a B (EVD5X..S..B) are not yet listed in ENERGY STAR, unlike serial numbers with an A (EVD5X..M..A), which are certified with the Q5H9V and N5H9V heat pumps. For approved matches, AHRI is the authority.

The three 3.5-ton models side by side

  • EVD5X42S17B: 17-1/2 in, for a narrow furnace.
  • EVD5X42S21B (this one): 21 in, for a mid-size furnace.
  • EVD5X42S24B: 24-1/2 in, for a wide furnace.

If your need is closer to 4 tons with the same 21 in width, look at the EVD5X48S21B. And if the target capacity is 5 tons at 21 in, two models exist, the EVD5X60S21B and the EVD5X61S21B. All of these models use R-454B and the TXV metering device.

EVD5X42S21B spec sheet

  • type: cased evaporator coil;
  • series: EVD5X;
  • nominal size: 3.5 tons (42,000 BTU/h);
  • refrigerant: R-454B;
  • width: 21 in;
  • connections: 3/8 in for the liquid, 7/8 in for the suction;
  • metering device: TXV;
  • condensate pan: PBT, sloped, three sealed plugs;
  • leak detection: factory-installed A2L sensor, no mitigation board; furnace with built-in mitigation or ACAENCDIS01A kit required;
  • warranty: 10-year limited warranty on parts if registered within 90 days of installation, otherwise 5 years.

How we work

AirGreen, a family-owned heating and cooling company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01. On this job, we:

  • measure the furnace and check the blower and the electrical panel;
  • install the coil in the plenum and seal the air joints, with a transition built on site if necessary;
  • install the outdoor unit, braze the piping, run the nitrogen test and pull the vacuum;
  • connect the condensate drain and the thermostat;
  • start the system, adjust the airflow and explain how it works.

Questions we often hear

My furnace is a little under 21 in. Is that a problem? No. We build an insulated transition on site and work it into the plenum.

Can I keep my current air conditioner? Generally, no. The coil runs on R-454B and is matched with the outdoor unit specified by the manufacturer; we install the complete system.

Does the furnace become useless with a heat pump? Quite the opposite: it keeps its blower and its filters, and serves as backup heat during the coldest weather.

Does this coil heat? Yes, when it is connected to a heat pump. With a central air conditioner, it only cools.

Three checks before buying

  • R-454B refrigerant for the whole system: coil and outdoor unit are installed together.
  • Published ratings valid for the certified match only.
  • Furnace width and blower airflow confirmed during the visit.

Hydro-Québec programs

Hydro-Québec programs assess the complete system, not an isolated part. At the time of the quote, we check the official list based on the installation date and tell you what applies.

Next step: a visit with a tape measure

Request your free on-site estimate. We measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing lets you spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The EVD5X42S21B sits in the plenum of a furnace or air handler. Connected to a matching Comfortmaker outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Comfortmaker outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerComfortmaker
ModelEVD5X42S21B
TypeCased evaporator coil
LineEVD5X
Nominal size3.5 tons (42,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D21 in
Model numberEVD5X42S21B
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 21 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
COMFORTMAKER
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3.5-ton Comfortmaker coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.