DURASTAR DRBEF2417STANMC Evaporator N-Coil | 2 Tons
The Durastar DRBEF2417STANMC 2-ton R-454B cased coil sits on your furnace and, matched with a matching Durastar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberDRBEF2417STANMC
514 316-2973 · sales@airgreen.ca
Quick facts
The DRBEF2417STANMC: a 43 lb N-coil, 2 tons, for a basement staircase that forgives nothing
Equipment that does not fit well into the house is installed badly. Before capacity and refrigerant, we think about the route: front door, staircase, the corner of the mechanical room. At 43 lb net, the Durastar DRBEF2417STANMC evaporator coil can be handled without special equipment, which matters in finished basements in Montreal, Laval and Longueuil.
It is a 2-ton (24,000 BTU/h) N-coil with a cabinet, so a cased coil, 17-1/2 in wide, running on R-454B. Our team also installs it on the North Shore and on the South Shore.
At a glance
- A coil that completes an existing furnace;
- Air conditioning in summer; heating in winter with a heat pump;
- A required match with an outdoor unit of the same capacity and the same refrigerant;
- Installation in a single pass, with the furnace kept in place.
The coil's route, from the van to the furnace
The cabinet arrives ready to install. Two technicians carry it to the plenum, shim it, then connect it. At 43 lb, it needs no mechanical lifting: no hoist or scaffolding. That reduces the risk of scuffing a finished wall or a step.
Once in place, we seal the duct joints and check that nothing moves. A poorly shimmed coil produces vibration, then condensation in places where it has no business being.
N shape: three faces, a lower cabinet
The fins of an N-coil form a zigzag. They offer the needed heat-exchange surface in a shorter volume than an A-coil. Under a beam, at the bottom of a basement ceiling or in a small utility room, that economy of height makes all the difference.
The manufacturer lists multi-position installation: upflow, downflow, horizontal left or right. A TXV-type expansion valve adjusts the refrigerant supply according to the air temperature.
What you cannot see: leak detection
Refrigerants in the A2L family, including R-454B, have led manufacturers to build in a safety device. On this model, an A2L sensor and a mitigation board are combined in a single housing, factory-installed on models without the L suffix. If excess refrigerant is detected, the outdoor unit pauses. The whole thing works with any 24 V thermostat.
Data sheet details
- Nominal capacity: 2 tons, 24,000 BTU/h;
- Width: 17-1/2 in; net weight: 43 lb;
- R-454B refrigerant, TXV expansion valve;
- 3/8 in liquid connection, 3/4 in suction;
- Two 3/4 in NPT condensate connections;
- DRBEF series; type: cased evaporator coil;
- Warranty: ten years on parts, subject to registration.
How to tell this model from its siblings
The DRBEF2417STANMC looks a lot like the DRBEF2417MTANMC: same N shape, same 2-ton capacity, same 17-1/2 in width, same R-454B and same TXV. The difference visible on the data sheets comes down to net weight and part reference. Ask us for the comparison at the estimate; we draw it up from the manufacturer's document.
Other pointers to decide:
- A 2-ton "A" such as the DRBEF2414STAAMC takes more height than an "N";
- The DRBEF2421HTANMC and DRBEF2421MTANMC are also 2-ton "N" coils, with no width listed on the data sheet;
- For a larger home, look at the 3-ton models; the DRBEF3617STANMC keeps the 17-1/2 in width.
The complete system: who talks to whom
The coil, on its own, has no efficiency rating. The SEER2 and HSPF2 ratings in circulation describe a match, tied to an AHRI number. Before ordering, we look up that number for the chosen outdoor unit, so that the promise in the quote is exactly that of the equipment delivered.
Our rule is simple: a coil and an outdoor unit that do not appear together in the directory are not matched at AirGreen.
A five-step installation
- Visit: measuring the furnace, the blower and the electrical panel;
- Coil: set in the plenum, insulated transition if needed;
- Outdoor unit: pad or bracket, brazed piping, nitrogen test, vacuum;
- Connections: condensate drain, thermostat;
- Testing: start-up, airflow adjustment, walk-through.
The work is carried out under RBQ licence 5645-9605-01. AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years.
Before you say yes
- Same refrigerant on both sides: R-454B;
- Furnace width confirmed against the 17-1/2 in;
- Blower able to deliver the airflow required;
- Ratings read from the certified match, not from the coil alone.
Getting an installation right in a finished basement
Many of our customers have finished their basements: suspended ceiling, playroom, small office. In that case, the mechanical room is often the only place left unfinished, and space there is tight. We take the time to protect the floors, cover nearby surfaces and locate the piping pass-throughs before starting.
The refrigerant piping between the furnace and the outdoor unit follows a route that we plan with you. We look for the shortest and most discreet path, without kinking the tubes, and we insulate what needs it. A good layout also simplifies future service.
Questions we are often asked
Can this coil provide heat? Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner, it only provides cooling.
Can I keep my current air conditioner? Generally no. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
What if my furnace is not the same width? We measure it and, if needed, build an insulated transition on site.
Is the furnace still useful? Yes. It keeps its blower and takes over when the outdoor temperature falls below the threshold we program with you.
One simple step after installation
Fill out the manufacturer's registration form: that is what makes the ten-year parts warranty applicable. We help you do it on start-up day, so nothing is forgotten.
Maintaining what you cannot see
Once the cabinet is closed up, nobody looks at it for years. Yet that is where dust builds up on the fins and where the pan can collect deposits. A check before the warm season lets us clean what needs cleaning, check the drain and make sure the airflow has not dropped. It takes little time and protects the investment.
Financial help
Hydro-Québec incentives, notably LogisVert, are tied to the complete system. The amount and eligibility vary with the installation date: we check the official list when we prepare your quote and tell you what concerns your file.
The manufacturer
Durastar is the heating and cooling brand of Ferguson; Wolseley distributes it in Canada. DRBEF coils running on R-454B are installed on a furnace to complete Durastar heat pumps and central air conditioners.
Next step: the estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The DRBEF2417STANMC sits in the plenum of a furnace or air handler. Connected to a matching Durastar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Durastar outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
DURASTARSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2-ton Durastar coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.