DURASTAR DRBEF2421HTANMC Evaporator N-Coil | 2 Tons
The Durastar DRBEF2421HTANMC 2-ton R-454B cased coil sits on your furnace and, matched with a matching Durastar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberDRBEF2421HTANMC
514 316-2973 · sales@airgreen.ca
Quick facts
DRBEF2421HTANMC: a 2-ton N-coil, 7/8 in suction and 71 lb of well-seated metal
Some coils are chosen by capacity. Others are read by their piping. The Durastar DRBEF2421HTANMC belongs to the second category: its data sheet lists a 7/8 in suction connection, larger than that of several 2-ton models in the series, and a net weight of 71 lb. Those two details steer the installation, long before anyone talks about thermostat colour.
This 2-ton (24,000 BTU/h) N-coil, supplied in a cabinet and so a cased coil, uses R-454B refrigerant. AirGreen connects it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
Why the suction diameter deserves a closer look
Two tubes run between the outdoor unit and the coil. The thinner one carries liquid refrigerant: here, 3/8 in. The larger one brings the gas back to the compressor: here, 7/8 in. A tube that is too narrow hampers that return; a poorly insulated tube lets heat creep in along the way.
Our job is to connect those two diameters to the existing piping or to run a new compliant line. When the tubes in place do not match, we replace them rather than force a fitting.
71 lb: plan for solid support
A 71 lb cabinet calls for a plenum in good shape and a support that will not give way over time. We check the rigidity of the sheet metal, the alignment with the furnace and the way the mass is distributed. A coil that works every day, with condensate collecting on it, deserves a well-shimmed mounting.
It takes two people to handle. We plan the basement delivery accordingly and protect the route from the door to the mechanical room.
The N shape explained without jargon
Three faces of fins arranged in a zigzag, rather than two meeting at a point: that is the N-coil. It fits in a shorter cabinet than an A-coil. That choice makes sense when the plenum is low or when a duct, a beam or a ceiling limits the available height.
The manufacturer lists multi-position installation: upflow, downflow, horizontal left or right. The expansion valve is a TXV.
The DRBEF2421HTANMC data sheet at a glance
- Nominal capacity: 2 tons (24,000 BTU/h);
- Refrigerant: R-454B;
- Expansion valve: TXV;
- Connections: 3/8 in liquid, 7/8 in suction;
- Condensate: two 3/4 in NPT connections;
- Net weight: 71 lb;
- Safety: A2L sensor and mitigation board in a single housing, factory-installed on models without the L suffix; temporary shutdown of the outdoor unit if excess refrigerant is detected; compatible with any 24 V thermostat;
- Manufacturer's warranty: ten years on parts, conditional and with registration.
Choose it, or look elsewhere in the series?
A few pointers drawn from the DRBEF series data sheets:
- Same capacity, same shape: the DRBEF2421MTANMC is also a 2-ton "N", with no width listed on its data sheet. Its weight and connection values differ; we compare the two data sheets with you;
- Known width of 17-1/2 in: the DRBEF2417MTANMC and DRBEF2417STANMC give it, which makes it easier to fit a narrow furnace;
- Different shape: the DRBEF2414STAAMC is an "A";
- More capacity: the 3-ton models, such as the DRBEF3621HTAAMC or DRBEF3621MTANMC, are for larger homes.
If your home is modest but the existing piping is already large-gauge, or if it will be redone, this model holds its own very well.
What the coil does through the seasons
In summer, the refrigerant boils inside the tubes and picks up heat from the air passing through them. That air, cooled and dehumidified, goes back into the ducts. In winter, with a heat pump, the cycle reverses and the heat collected outside is delivered to the house. The furnace keeps its filters, its blower and its backup role for the harshest cold.
A coil has no efficiency rating of its own. The match and its AHRI number carry the SEER2, EER2 and HSPF2 ratings. We check that number before any order.
The installation, step by step
- Assessment of the furnace, the blower and the electrical panel;
- Setting the coil in the plenum, with an insulated transition on site if needed;
- Brazed refrigerant piping, nitrogen leak test, vacuum;
- Connecting the drain and the thermostat;
- Start-up and airflow adjustment.
Brazing, vacuum pulling and electrical connections are done under RBQ licence 5645-9605-01. Our family-run heating and cooling company has been in Montreal for more than fifteen years.
The final look before ordering
- The outdoor unit must run on R-454B, like the coil;
- The furnace width must be checked before ordering;
- The blower must deliver the system's airflow;
- Incentives depend on the complete system.
Brazing, nitrogen, vacuum: the three steps that make it last
Refrigerant fittings are brazed under a light flow of nitrogen, so that the inside of the tube stays clean. Then we pressurize the line to look for the slightest leak, and pull a vacuum to remove air and moisture before opening the refrigerant.
These steps are more demanding on a large-diameter suction tube, because the surfaces to heat and insulate are larger. We allow the time needed, and we skip no step to save an hour.
Finally, we insulate the suction line along its whole visible length. A cold, bare tube drips in summer, and a dripping tube eventually stains a ceiling or a wall.
Why the suction line belongs in a quote
A serious quote states the diameter of the connections and the nature of the piping. That lets you compare two offers on the same basis: one may include a new line, the other may reuse the existing one. Ask for this information in writing; it often explains part of the price gap between two contractors.
Incentive and paperwork
Eligibility for Hydro-Québec programs, including LogisVert, is determined on the matched system, not on the coil alone. We check the official list according to the installation date, then tell you what applies to your project.
About the brand
Durastar is the heating and cooling brand of Ferguson, which Wolseley distributes in Canada. Its DRBEF coils running on R-454B are installed on a furnace to go with Durastar heat pumps and central air conditioners.
A word on maintenance after installation
A coil of this weight benefits from a periodic check: clean fins, a pan free of deposits, a drain that runs freely. We give you a simple list of what to look at yourself and what calls for a technician. A check visit before summer can catch a weeping joint or an overloaded filter.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The DRBEF2421HTANMC sits in the plenum of a furnace or air handler. Connected to a matching Durastar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Durastar outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- We check the furnace width before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
DURASTARSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2-ton Durastar coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.