DURASTAR DRBEF3621HTAAMC Evaporator A-Coil | 3 Tons

In stock

The Durastar DRBEF3621HTAAMC 3-ton R-454B cased coil sits on your furnace and, matched with a matching Durastar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberDRBEF3621HTAAMC

3 tons36,000 BTU/h nominal
casedtype
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberDRBEF3621HTAAMC
ManufacturerDurastar
Size3 tons
RefrigerantR-454B
MeteringTXV

DRBEF3621HTAAMC: the 3-ton A-coil, 76 lb, for the two-storey home with an upflow furnace

The large suburban two-storey home has its habits: a basement furnace that blows upward, a duct network serving two floors, and summers when the upper floor turns into a steam room. For that profile, the Durastar DRBEF3621HTAAMC evaporator coil has good arguments. It is a 3-ton (36,000 BTU/h) A-coil with a cabinet, so a cased coil, running on R-454B refrigerant.

We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, in homes where central air conditioning must reach the upper floor without overloading the main floor.

A 3-ton size for a multi-storey home

The larger the home, the more air there is to treat, and the more generous the coil's heat-exchange surface must be. The 3-ton size is there for that. It suits many two-level suburban homes with a basement, provided the load calculation confirms it.

We insist on that calculation. If your home needs less, we steer you to a 2-ton model; if it needs more, we tell you that too. In every case, the quote is based on the house, not on what is in stock.

Why an "A" on an upflow furnace

The A-coil is made of two fin plates leaning together and joined at the top. Air arrives from below, rises through the centre and passes through both faces. On an upflow furnace, it is a natural arrangement, one we know well. It needs a little more height above the furnace than an N-coil: so we measure the plenum space before proposing it.

The manufacturer lists multi-position installation: upflow, downflow, horizontal left or right. The expansion valve is a TXV.

The weight: 76 lb to carry and to support

The listed net weight is 76 lb. That means two technicians for handling and a plenum that must be solid. We check the sheet metal, the supports and the alignment, then seal all the joints.

That mass has an advantage: a sturdy cabinet stands up better to years of use and condensation. It only requires preparing the route through the house well, particularly in a narrow basement staircase.

7/8 in connections: the piping follows

This coil's connections are 3/8 in for liquid and 7/8 in for suction. That suction line calls for careful brazing, a good nitrogen test and complete insulation. We check the existing piping: if it is not suitable, we run a new line.

What to remember from the data sheet

  • Model DRBEF3621HTAAMC, cased coil, DRBEF series;
  • Nominal capacity: 3 tons (36,000 BTU/h);
  • R-454B refrigerant; TXV expansion valve;
  • Connections: 3/8 in liquid, 7/8 in suction;
  • Condensate: two 3/4 in NPT connections;
  • Net weight: 76 lb;
  • Built-in leak detection: A2L sensor and mitigation board, factory-installed on models without the L suffix, pausing the outdoor unit if excess refrigerant is detected, compatible with any 24 V thermostat;
  • Conditional 10-year parts warranty, with registration.

Should you choose this one over another 3-ton?

The series offers five 3-ton coils. Here is how to tell them apart from the published data:

  • The "A" coils: the DRBEF3621HTAAMC and DRBEF3621MTAAMC share the same shape and the same data sheet values; we help you choose according to the reference your match calls for;
  • The "N" coils: the DRBEF3617STANMC, DRBEF3621MTANMC and DRBEF3621STANMC, lower, for a plenum with limited height;
  • Designated match: the DRBEF3617STANMC and DRBEF3621STANMC are tied to the DRHP15B36AJ2AN unit;
  • Width of 17-1/2 in: published only for the DRBEF3617STANMC.

If your furnace has height to spare and you want the classic A shape, this model fits well.

Cooling and heating: how the roles are split

In summer, the refrigerant evaporating in the coil removes heat from the air and condenses the moisture. Upstairs, that means bedrooms where you sleep better. In winter, with a heat pump, the cycle reverses and the same ducts carry heated air. The furnace takes over below the temperature threshold we set with you.

The coil has no efficiency rating of its own: the SEER2, EER2 and HSPF2 ratings belong to the certified match, and an AHRI number ties them together.

Matching with the outdoor unit

This coil is matched with a Durastar outdoor unit of the same capacity and the same refrigerant. We check the exact match and its AHRI number in the directory before ordering. The outdoor heat pump and the coil are installed together, with the same refrigerant.

Installation day

  • Assessment of the furnace, the blower and the electrical panel;
  • Installing the coil and sealing the duct connections;
  • Installing the outdoor unit, brazing, nitrogen test, vacuum;
  • Connecting the drain and the thermostat;
  • Start-up, airflow adjustment, walk-through.

We work under RBQ licence 5645-9605-01. AirGreen, a family-run heating and cooling company, has been based in Montreal for more than fifteen years.

The usual checks

  • Same refrigerant on both sides: R-454B;
  • Enough height above the furnace for an "A";
  • Furnace width confirmed before ordering;
  • Blower able to deliver the system's airflow.

Hydro-Québec incentives

Eligibility for LogisVert and the other programs depends on the complete system, not on the coil alone. We check the official list according to the installation date and tell you what applies to your project.

The brand

Durastar is the heating and cooling brand of Ferguson, distributed in Canada by Wolseley. Its DRBEF coils running on R-454B go with the brand's heat pumps and central air conditioners.

Comfort upstairs, a detail that changes everything

In a multi-storey home, a single thermostat does not tell the whole story. Warm air rises, the upstairs bedroom is often the warmest, and the basement room the coolest. A well-set airflow and balanced registers help spread the comfort. We check these settings at start-up and adjust them with you on the first hot day.

Planning maintenance for a sturdy cabinet

A coil installed on a furnace is cleaned from the plenum. We leave convenient access and show you where the pan is. The filter remains the most important element: clean, it protects the fins from dust and extends the life of the blower.

Plan for a check before the cooling season and another before heating. Our team serves Montreal, Laval, Longueuil, the North Shore and the South Shore, and schedules these visits with you according to your calendar, so the system is ready before the first big heat.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The DRBEF3621HTAAMC sits in the plenum of a furnace or air handler. Connected to a matching Durastar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Durastar outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDurastar
ModelDRBEF3621HTAAMC
TypeCased evaporator coil
LineDRBEF
Nominal size3 tons (36,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Net weight76 lb
Model numberDRBEF3621HTAAMC
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • We check the furnace width before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
DURASTAR
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3-ton Durastar coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.