DRBEF3617STANMC and DRHP15B36AJ2AN: reading the data sheet of a 3-ton system before signing
A coil never appears alone in front of an inspector, an incentive adviser or a methodical buyer. It arrives with an outdoor unit and a certificate number. For the Durastar DRBEF3617STANMC evaporator coil, that companion is the DRHP15B36AJ2AN outdoor unit, and the certificate is called AHRI.
The DRBEF3617STANMC is a 3-ton (36,000 BTU/h) N-coil with a cabinet, so a cased coil, 17-1/2 in wide, using R-454B refrigerant. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
Two AHRI numbers, one coil model
The directory publishes two matches for this coil, both with the DRHP15B36AJ2AN heat pump:
- AHRI 216686921;
- AHRI 216686924.
In both cases, the published ratings are the same: 34,200 BTU/h cooling, 34,200 BTU/h heating at 47 °F, SEER2 of 15.2 and HSPF2 of 7.8. These values describe the system, not the coil alone. When a quote cites an AHRI number, we compare it with these two references.
What these ratings mean for your bill
SEER2 measures seasonal efficiency in cooling; HSPF2, seasonal efficiency in heating. The higher the value, the less the system uses for the same amount of comfort. A quote that does not tie them to a match number remains a promise with nothing behind it.
We do not ask you to believe a rating: we hand you the directory reference. You can check it yourself.
Where this 3-ton fits
The 3-ton size covers a large share of the region's bungalows and cottages: furnace in the basement, ducts to every room, a window air conditioner in the bedroom in summer. The coil is installed on the furnace. The home keeps its ducts and moves to a system that cools, then heats when matched with a heat pump.
Our role is to confirm, through a load calculation, that 3 tons is right. If the house needs less or more, we propose another size in the series.
The N shape and its 17-1/2 in width
The N is a coil with three faces folded in a zigzag, in a cabinet that is lower than an A-coil. The data sheet gives the dimensions as 17-1/2 in wide, with a size of 445 × 454 × 508 mm (A × B × C). If your furnace has a different width, we build an insulated transition on site.
The manufacturer lists multi-position installation: upflow, downflow, horizontal left or right. The expansion valve is a TXV, which adapts the refrigerant flow to demand.
Technical features
- Type: cased coil; DRBEF series;
- Size: 3 tons (36,000 BTU/h);
- Refrigerant: R-454B; expansion valve: TXV;
- Dimensions (W × H × D): 17-1/2 in (445 × 454 × 508 (A × B × C) mm);
- Net weight: 49 lb;
- Connections: 3/8 in for liquid, 3/4 in for suction;
- Condensate drain: two 3/4 in NPT connections;
- Leak detection: A2L sensor and mitigation board in a single housing, factory-installed (models without the L suffix); the outdoor unit is paused if excess refrigerant is detected; compatible with any 24 V thermostat;
- Warranty: ten years on parts, conditional, with registration.
How this coil compares with others in the series
- Same capacity and same outdoor unit: the DRBEF3621STANMC is also matched with the DRHP15B36AJ2AN, with its own AHRI numbers. It lists no width on the data sheet;
- Width of 17-1/2 in: among the 3-ton coils in the series, only the DRBEF3617STANMC gives it;
- A-shape at 3 tons: the DRBEF3621HTAAMC and DRBEF3621MTAAMC;
- Another N at 3 tons: the DRBEF3621MTANMC;
- Less capacity: the 2-ton models, such as the DRBEF2417STANMC, share the 17-1/2 in width.
A match like no other
Many coils in the series are matched after the fact, depending on the outdoor unit available. This one has a designated pair. For a buyer, that is reassuring: you do not search, you verify. For us, it simplifies the order and the incentive file.
Our job site routine
- Measuring the furnace, checking the blower and the electrical panel;
- Setting the coil in the plenum and sealing the duct connections;
- Installing the DRHP15B36AJ2AN outdoor unit on a pad or bracket;
- Brazed piping, nitrogen test and vacuum;
- Connecting the drain and thermostat, start-up, airflow adjustment.
We work under RBQ licence 5645-9605-01. AirGreen, a family-run heating and cooling company, has been based in Montreal for more than fifteen years.
To check before ordering
- Both units use R-454B and are installed at the same time;
- The furnace width matches the 17-1/2 in, or a transition is planned;
- The blower can sustain the system's airflow;
- The coil has no efficiency rating of its own: the values you read belong to the system.
Why we prefer a designated match
When a coil and an outdoor unit are published together under an AHRI number, verification is direct: you look up the number, read the ratings and compare them with the quote. With a free-form assembly, you have to guess which combination was tested. That clarity makes the decision calmer for you, and it reduces the risk of error at the order.
Frequently asked questions about this system
Can this coil provide heat? Yes, with the DRHP15B36AJ2AN heat pump: it cools in summer and heats in winter. With a central air conditioner, it only provides cooling.
Can I reuse my current outdoor unit? Generally no: the coil runs on R-454B and is matched with the unit specified by the manufacturer.
Is the furnace still used? Yes, as backup heating, with its blower and its filters.
Keep these three documents
When the job is finished, keep the signed quote, the manufacturer's registration form and the AHRI number of the installed system. These three items are enough to prove what was installed, to claim the ten-year parts warranty and to answer a question from your insurer or a future buyer of the home.
We file them with you in a simple folder, paper or digital, as you prefer. A buyer who sees an AHRI number and proof of registration understands right away that the system was installed by the book.
We take this step to remind you of the essentials of maintenance: clean filter, clear outdoor unit, watched drain.
LogisVert incentive
The matched Durastar system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation. We check it on the official list when we prepare the quote and put the file together with you.
A word on Durastar
Durastar is the heating and cooling brand of Ferguson, distributed in Canada by Wolseley. The DRHP14B and DRHP15B heat pumps in the DRAC series run on R-454B with a two-stage compressor and are matched with DRBEF coils and a Durastar furnace.
Estimate and financing
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The DRBEF3617STANMC sits in the plenum of a furnace or air handler. Connected to the Durastar DRHP15B36AJ2AN outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Durastar DRHP15B36AJ2AN outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
DURASTARSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton Durastar coil, installed by AirGreen