DURASTAR DRBEF3621MTAAMC Evaporator A-Coil | 3 Tons

In stock

The Durastar DRBEF3621MTAAMC 3-ton R-454B cased coil sits on your furnace and, matched with a matching Durastar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberDRBEF3621MTAAMC

3 tons36,000 BTU/h nominal
casedtype
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberDRBEF3621MTAAMC
ManufacturerDurastar
Size3 tons
RefrigerantR-454B
MeteringTXV

DRBEF3621MTAAMC: choosing the coil position, from vertical plenum to horizontal attic

The same furnace is not installed the same way in every home. Some blow upward from a basement. Others blow downward from an attic or a crawl space. Still others lie on their side in a ceiling space. The Durastar DRBEF3621MTAAMC evaporator coil has been published by the manufacturer as multi-position: upflow, downflow, horizontal left or horizontal right.

It is a 3-ton (36,000 BTU/h) A-coil with a cabinet, so a cased coil, using R-454B refrigerant. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

Four positions, four questions to ask

Before choosing a coil, we look at how the furnace is installed:

  • Upflow: the furnace is in the basement and blows upward; the coil goes on top;
  • Downflow: the furnace is up high and blows downward; the coil goes below the plenum;
  • Horizontal left: the furnace lies on its side and the air moves in one direction;
  • Horizontal right: the furnace lies on its side and the air moves in the other direction.

The DRBEF3621MTAAMC is listed for all four cases. We confirm on site that your configuration is one of them and we arrange the drain accordingly.

The condensate drain rules

A coil at work produces water. In a horizontal position especially, the slope of the pan and the direction of the drain decide everything: if the water does not leave, it overflows. This model has two 3/4 in NPT condensate connections. We use the one that matches the chosen position and cap the other neatly.

In an attic or a ceiling space, we provide a safety pan and an exit path, so that a possible leak does not stain a ceiling.

An A-coil, with the weight that goes with it

The two inclined faces, joined at the top, form the letter A. It is a classic and sturdy configuration. The listed net weight is 76 lb, which calls for two technicians and a solid support. We check the plenum, its joints and its fastening before proceeding.

The expansion valve is a TXV, which regulates the refrigerant flow according to the load of the air to be treated.

The connections and safety

  • Liquid: 3/8 in; suction: 7/8 in;
  • Leak detection: A2L sensor and mitigation board in a single housing, factory-installed on models without the L suffix; if excess refrigerant is detected, the outdoor unit stops temporarily;
  • Compatible with any 24 V thermostat.

Data sheet summary

  • Model: DRBEF3621MTAAMC, DRBEF series;
  • Type: cased evaporator coil;
  • Nominal size: 3 tons, or 36,000 BTU/h;
  • Refrigerant: R-454B;
  • Net weight: 76 lb;
  • Conditional 10-year parts warranty, with registration.

A twin in the series: the DRBEF3621HTAAMC

The data sheets of the DRBEF3621MTAAMC and the DRBEF3621HTAAMC list the same values: 3 tons, A shape, R-454B, TXV, 3/8 in and 7/8 in connections, 76 lb. They differ by their part reference. We ask the manufacturer to confirm the exact correspondence between the reference and your match before placing the order; it is a quick check that avoids a return of equipment.

For the others, here is how to tell them apart:

  • A 3-ton "N": the DRBEF3617STANMC, DRBEF3621MTANMC and DRBEF3621STANMC, lower;
  • A width of 17-1/2 in: published for the DRBEF3617STANMC;
  • Less capacity: the 2-ton models, including the DRBEF2414STAAMC, also an "A".

The coil's role in your system

It receives refrigerant from the outdoor unit and cools the air moving through your ducts. With a heat pump, it also gives back heat from outdoors in winter. It has no efficiency rating of its own: the published values belong to the certified match, identified by an AHRI number.

The outdoor unit must have the same capacity and the same refrigerant. We look up its number in the directory before the order.

Our installation method

  • Technical visit: furnace, blower, electrical panel, installation position;
  • Installing the coil in the chosen position, with sealed joints;
  • Outdoor unit on a pad or bracket; brazed piping; nitrogen test; vacuum;
  • Condensate drain and thermostat connected;
  • Start-up, airflow adjustment, explanations.

RBQ licence 5645-9605-01 covers our refrigeration, ventilation and electrical work. AirGreen, a family-run heating and cooling company, has been based in Montreal for more than fifteen years.

Before ordering, let's check together

  • Same refrigerant, R-454B, for the coil and the outdoor unit;
  • Furnace installation position confirmed;
  • Furnace width checked;
  • Blower able to deliver the required airflow.

Incentives

Hydro-Québec programs, notably LogisVert, take the matched system into account, not the coil alone. We check the official list according to the installation date and tell you what applies.

Durastar

Durastar is the heating and cooling brand of Ferguson, distributed in Canada by Wolseley. DRBEF coils running on R-454B are installed on a furnace and go with the brand's heat pumps and central air conditioners.

If your furnace is in a tight space

A low attic, a crawl space or a utility closet needs a little preparation: a clear path, lighting, a safe working floor. We come to look before quoting, take photos and tell you honestly whether access is workable. Better to know at the estimate than during the installation.

A concrete example: the attic furnace

Picture a home whose furnace is in the attic space, above the second floor, blowing downward into the ducts. In that case, the coil goes in the downflow position. The weight of the cabinet then rests on the structure of the unit, which must be solid, and the condensate drain must run down without ever risking an overflow onto a ceiling.

We provide a safety pan, a secondary drain when useful, and access for maintenance. The attic floor is made safe so the work is done cleanly and without risk. This type of job takes a bit more preparation, but it goes very well when everything has been planned during the visit.

What the configuration changes at the thermostat

Nothing changes for you. The thermostat controls the whole system the same way, whatever the position of the coil. You set the temperature, and the system takes care of the rest. The position is only a matter of installation.

Installation day, on the home side

Plan to clear the path to the furnace and put away whatever clutters the mechanical room. If a pet moves about freely, think about placing it in a room away from the work. The installation may require briefly shutting off the heat and the power; we warn you in advance and put everything back on before we leave.

Book your estimate appointment

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The DRBEF3621MTAAMC sits in the plenum of a furnace or air handler. Connected to a matching Durastar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Durastar outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDurastar
ModelDRBEF3621MTAAMC
TypeCased evaporator coil
LineDRBEF
Nominal size3 tons (36,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Net weight76 lb
Model numberDRBEF3621MTAAMC
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • We check the furnace width before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
DURASTAR
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3-ton Durastar coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.