GOODMAN CAPFA3626B3 Evaporator A-Coil | 3 Tons

In stock

The Goodman CAPFA3626B3 3-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCAPFA3626B3

3 tons36,000 BTU/h nominal
17-1/2 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedR-32
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCAPFA3626B3
ManufacturerGoodman
Size3 tons
Width17-1/2 in
RefrigerantR-32
MeteringPiston

Goodman CAPFA3626B3 coil: 3 tons in a narrow 17-1/2 in cabinet

Some furnaces are slim. You find them in row houses, small bungalows from the sixties and utility closets where every inch counts. For those units, the CAPFA3626B3 is the 3-ton model in the Goodman CAPFA series that best fits the footprint: its cabinet is only 17-1/2 in wide.

It is a 3-ton (36,000 BTU/h) cased A-coil running on R-32 refrigerant, designed to mount on a furnace or a blower cabinet. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

Why width often decides the model

When shopping for a coil, people think of tons first. Yet in the field, width is what causes trouble first. A cabinet wider than the furnace forces us to build a transition, and a transition costs time and space. A cabinet well matched to the furnace sits straight, with short connections and a seal that is easier to get right.

The CAPFA3626B3 measures 17-1/2 × 26 × 21 in. It therefore suits compact furnaces whose air rises through a narrow plenum. If yours is wider, we measure it at the visit and tell you honestly whether another model in the series would make more sense.

How it compares with its neighbours in the series

Three coils in the family offer 3 tons. They share the A shape, R-32 refrigerant, the piston metering device and the same height. Only the width sets them apart:

  • CAPFA3626B3 (this one): 17-1/2 in, the narrowest of the three;
  • CAPFA3626C3: 21 in, for medium-width furnaces;
  • CAPFA3626D3: 24-1/2 in, for large furnaces.

Above it, the series also offers three 3.5-ton models in these same widths, a 4-ton model at 21 in and a 5-ton model at 24-1/2 in. Below it, there is a single 2.5-ton coil, at 24-1/2 in. The CAPFA3626B3 is therefore the only one to combine 3 tons with the slimmest width in the whole range.

A typical installation day

In the morning, we cut the power, remove the old coil if there is one, and measure the plenum. The insulated cabinet is then mounted on the furnace and sealed to the ducts. Meanwhile, the outdoor unit is set on its bracket, and the copper piping is carefully brazed between the two.

In the afternoon, we pressure-test with nitrogen, pull a vacuum, connect the condensate drain and the thermostat, then start the system. Before leaving, we adjust the airflow and go over the basic settings with you.

The "add-on" mode: keeping your furnace

With a heat pump, the coil and the furnace work as a team. The heat pump supplies most of the heat when the outdoor air is not too cold. The furnace, with its blower and filters, stays in place and takes over below a temperature threshold that we program with you.

The advantage is simple: no new ducts, no opened walls, and a backup heat source that already knows your home.

What the coil doesn't tell you on its own

The CAPFA3626B3 has no efficiency rating of its own. The published ratings belong to the matched system, the one that links this coil to a specific outdoor unit under an AHRI number. We confirm that number before ordering.

  • No R-32 match with this coil is listed with ENERGY STAR (dataset w7cv-9xjt, checked on 2026-11-26); AHRI remains the reference for the outdoor unit chosen.
  • Goodman offers a 10-year limited parts warranty, with online registration within 60 days of installation (not required in Quebec).

Technical data at a glance

  • model: CAPFA3626B3, cased evaporator coil;
  • nominal capacity: 3 tons (36,000 BTU/h);
  • refrigerant: R-32, leak sensor designed for the life of the coil;
  • metering device: piston;
  • positions: upflow or downflow;
  • 3/8 in liquid connection, 7/8 in suction connection;
  • condensate drain: 3/4 in FNPT, primary and secondary;
  • dimensions W × H × D: 17-1/2 × 26 × 21 in.

Which home suits a 3-ton coil?

The 3-ton size serves a large share of the bungalows and cottages in the region: furnace in the basement, ducts to every room, and an old central air conditioner or window units in summer. A two-storey row house with generous windows also falls in this category.

A load calculation remains the best way to settle the question. A system that is too big shuts off and restarts constantly; one that is too small runs out of breath on hot days. We look for the happy medium.

What you gain from an insulated cabinet

The CAPFA3626B3 ships in an insulated cabinet, ready to install on the furnace. This casing limits condensation on the walls and reduces air leaks between the plenum and the coil. Installation is faster than with an uncased coil that has to be enclosed on site, and the seal is easier to control.

In a tight space, that is a real advantage: fewer materials to handle, fewer joints to seal, fewer places for air to sneak through.

Frequently asked questions

Can the coil be used for heating? Yes, with a heat pump. With a central air conditioner, it only provides cooling.

Can my old air conditioner stay? Generally no: R-32 requires the outdoor unit specified by the manufacturer, and we install the two together.

What if my furnace is wider than 17-1/2 in? We measure the unit and, if needed, build an insulated transition on site, or steer you toward a wider model.

The small constraints that matter in a tight space

In a utility closet or a basement corner, you can't manoeuvre as you would in a large room. We plan access to the filter, the pan and the connections before we even start, and we leave the clearance a technician needs to come back for maintenance without taking everything apart. A system you can reach is a system you maintain.

We also avoid unnecessary elbows in the piping and insulate the refrigerant lines to limit condensation that could drip onto finished floors.

Our team, your project

AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is covered by RBQ licence 5645-9605-01. Your project includes measuring the furnace, checking the blower and the electrical panel, installing the coil, the outdoor unit, the piping, the vacuum and commissioning.

Points to confirm before ordering

  • The coil and the outdoor unit both run on R-32 and are installed together.
  • Efficiency ratings apply to the certified match.
  • The 17-1/2 in width and the blower must suit your furnace; we check everything on site.

Hydro-Québec incentives

Eligibility depends on the complete system and not on the coil alone. We consult the official list against the installation date, then explain what applies.

Get your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CAPFA3626B3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Goodman outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCAPFA3626B3
TypeCased evaporator coil
LineCAPFA
Nominal size3 tons (36,000 BTU/h)
RefrigerantR-32
Metering devicePiston
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D17-1/2 × 26 × 21 in
Model numberCAPFA3626B3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3-ton Goodman coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.