GOODMAN CAPFA6030C3 Evaporator A-Coil | 4 Tons
The Goodman CAPFA6030C3 4-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCAPFA6030C3
514 316-2973 · sales@airgreen.ca
Quick facts
CAPFA6030C3: a 4-ton coil, 30 in tall, for large homes with a furnace
At 4 tons (48,000 BTU/h), you move into a different category. The CAPFA6030C3 is no longer a coil for the average home: it targets large multi-storey houses, sprawling single-storey homes and properties with a fully finished basement. Its cabinet measures 21 in wide, 30 in tall and 21 in deep. It runs on R-32 refrigerant.
It is a cased A-coil from the Goodman CAPFA range, mounted on a furnace or a blower cabinet. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
What changes at 4 tons
A coil this size moves a lot of air. The airflow required is clearly higher than for the small sizes, and it is the furnace blower that has to deliver it. If it can't, the coil freezes or the house lacks comfort, which wastes the benefits of large equipment.
That is why the assessment visit matters as much as the product. We examine the blower, the plenum, the cross-section of the ducts and the return air. We confirm the size only after these checks.
A 30 in tall cabinet: what it means
The 30 in height is the most visible characteristic of this model. A taller cabinet houses more heat-exchange surface, but it also needs more clearance above the furnace. In a basement with a low ceiling, we measure carefully before committing. If the clearance is insufficient, we offer solutions: changing the position of the cabinet, moving a duct or choosing another size.
Where it sits among the nine models
- The only 4-ton in the series: no other model shares this capacity.
- 21 in width: the same as the CAPFA3626C3 (3 tons) and the CAPFA4226C3 (3.5 tons).
- One step up: the CAPFA6030D3, which offers 5 tons in a 24-1/2 in cabinet.
- One step down: the CAPFA4226C3 or the CAPFA4226D3, at 3.5 tons.
If your furnace measures 21 in and the house calls for more than 3.5 tons, this is the model to look at. For 5 tons, you have to move to a wide cabinet.
Do you really need 4 tons?
The question deserves to be asked frankly. A system that is too big runs in fits and starts, dries the air poorly and wears out its components faster. We prefer a serious load calculation to an impression. Sometimes it confirms 4 tons, especially in homes with large glass areas, high ceilings or several connected levels. Sometimes it recommends 3.5 tons, and we tell you so.
The heat pump and the furnace together
With a heat pump, the coil heats in winter through the existing ducts. The furnace stays in place with its blower, filters and heating elements, and takes over when the outdoor temperature drops below the threshold that we program together. It is a convenient solution for a large home: the heat pump does the bulk of the work, and the furnace covers the coldest periods.
Efficiency, ENERGY STAR, warranty
- The coil has no efficiency rating on its own; the ratings are those of the matched system, tied to an AHRI number.
- No R-32 match with this coil is listed with ENERGY STAR (dataset w7cv-9xjt, checked on 2026-11-26); we consult AHRI for the outdoor unit.
- 10-year limited parts warranty, with online registration within 60 days (not required in Quebec).
CAPFA6030C3 technical features
- type: cased evaporator coil;
- size: 4 tons (48,000 BTU/h);
- refrigerant: R-32, leak sensor designed for the life of the coil;
- metering device: piston;
- positions: upflow or downflow;
- connections: 3/8 in liquid, 7/8 in suction;
- condensate drain: 3/4 in FNPT, primary and secondary;
- dimensions: 21 × 30 × 21 in.
A large North Shore home, an example
Take a cottage on the North Shore with a finished basement, an open kitchen and a large picture window. In summer, heat builds up upstairs, and window units are no longer enough. A central system with a 4-ton coil, well matched and well tuned, spreads the cool air throughout the building using the existing ducts. What remains is to check that those ducts pass enough air; that is the point on which we spend the most time.
Common questions
Is my electrical service sufficient? We check it at the visit, because the outdoor unit needs its own circuit.
Does the furnace keep a role? Yes, as a backup source and as the blower.
Can I keep my old air conditioner? Generally not, because of R-32.
What if my furnace is narrower? We build and insulate a transition on site.
The role of return air in a large home
People talk a lot about supply registers, but it is often the return air that limits a large system. If air doesn't return easily enough to the furnace, the blower struggles, the coil gets too cold and comfort drops. In a multi-storey home, we check whether there is a return on each level and whether the grilles are big enough for the airflow of the CAPFA6030C3.
A simple fix, such as an extra return or an enlarged duct, costs less than oversized equipment, and it improves the result of the whole system.
Maintaining a system of this size
A large coil collects dust faster if the filter is neglected. We recommend checking the filter regularly and scheduling a visit before the hot season. Checking the pan, the drain and the connections takes little time and avoids bad surprises. We give you a short guide on what to look at between visits.
The AirGreen installation
AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. For this coil, we measure the furnace, check the blower and the electrical panel, mount the cabinet, seal the duct connections, install the outdoor unit, braze the piping, pressure-test with nitrogen, pull a vacuum, connect the drain and the thermostat, then adjust the airflow and explain how it works.
Keep in mind that a 4-ton coil is a significant investment: it is better to take an extra week to validate the sizing than to regret a poorly suited system. We remain reachable after the visit to answer your questions.
To check before choosing
- Coil and outdoor unit in R-32, installed together.
- Published ratings valid for the certified match.
- Blower, plenum, 30 in height clearance and 21 in width to be confirmed during the visit.
Incentives
Eligibility for Hydro-Québec programs depends on the complete system, not on the coil alone. We check the official list against the installation date and tell you what applies to your project.
Your on-site estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The CAPFA6030C3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Goodman outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 4-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.
