GOODMAN CAPFA3626C3 Evaporator A-Coil | 3 Tons
The Goodman CAPFA3626C3 3-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCAPFA3626C3
514 316-2973 · sales@airgreen.ca
Quick facts
CAPFA3626C3: the mid-width 3-ton coil, 21 in, for the most common furnace
If you had to draw the typical furnace in a Quebec basement, it would be about as wide as the CAPFA3626C3. This Goodman 3-ton (36,000 BTU/h) coil measures 21 in wide, 26 in tall and 21 in deep. It sits in the middle of the series, between the narrow and the wide model of the same size, and it is often the one that slips onto a standard furnace without a transition.
It runs on R-32 refrigerant and mounts on a furnace or a blower cabinet. Our crews work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
The mid-range compromise
Choosing a width isn't only a matter of inches. A cabinet too narrow for the furnace leaves gaps to fill; a cabinet too wide forces us to enlarge the air outlet or build an adapter. The CAPFA3626C3 avoids both extremes for a large number of units and leaves little room for surprises on installation day.
That said, we never assume the width of your furnace. We measure it, then compare it with the cabinet width before signing the quote.
The comparison at a glance
Here is how this coil fits among the nine models in the CAPFA series, all R-32 with a piston metering device:
- Same capacity, different width: the CAPFA3626B3 is 17-1/2 in and the CAPFA3626D3 goes up to 24-1/2 in, both at 3 tons;
- Same width, different capacity: the CAPFA4226C3 (3.5 tons) and the CAPFA6030C3 (4 tons) are also 21 in;
- Smaller: the CAPFA3022D3, at 2.5 tons, with a 24-1/2 in cabinet;
- Larger: the CAPFA6030D3, at 5 tons, also at 24-1/2 in.
In other words, you can move up or down in capacity without changing width, which is handy if your furnace is already fixed at 21 in.
Why 3 tons?
The 3-ton size is a balance point for many homes in the region: mid-size cottages, enlarged bungalows, two-storey semi-detached homes. A load calculation is needed to confirm, but 3 tons comes up often in our quotes because it avoids oversizing while still keeping up with hot July days.
The coil in your heat pump system
Placed in the plenum, the coil receives refrigerant from the outdoor unit. In summer, it absorbs heat from the air passing through it, and the moisture condenses in the pan. In winter, with a heat pump, the cycle reverses and the air is warmed by contact with the hot refrigerant.
The furnace keeps its filters and its blower. It also remains available as backup heat for deep cold, based on a temperature threshold that we program together.
Efficiency ratings: who do they belong to?
A coil has no rating on its own. The SEER2, EER2 and HSPF2 ratings describe a complete system, tied to an AHRI number. That number matters when comparing two quotes and for incentive programs.
- No R-32 match with this coil appears in ENERGY STAR (dataset w7cv-9xjt, checked on 2026-11-26); we therefore consult AHRI for the outdoor unit chosen.
- Goodman warranty: 10 years on parts, with online registration within 60 days (not required in Quebec).
CAPFA3626C3 specifications
- type: cased coil, CAPFA range;
- size: 3 tons (36,000 BTU/h);
- refrigerant: R-32, with leak sensor;
- metering device: piston;
- positions: upflow or downflow;
- connections: liquid 3/8 in, suction 7/8 in;
- condensate drain: 3/4 in FNPT, primary and secondary;
- dimensions: 21 × 26 × 21 in.
Cooling in summer also means drying
Many homeowners replace their window units with a central system for the quieter comfort and the even air distribution. A lesser-known detail: as it cools the air, the coil also dehumidifies it. In a home in Laval or on the North Shore during a muggy heat wave, the difference is felt in the bedrooms, where the air becomes drier and easier to breathe.
Three scenarios where 21 in fits just right
The replacement furnace. You change an old gas or oil furnace, or you keep the current unit and simply add air conditioning. In both cases, the 21 in cabinet matches most plenums of common size.
The resold home. You have just bought a cottage whose central air conditioner is at the end of its life. The new coil, paired with a new outdoor unit, gives you a coherent system, with no mix of ages or refrigerants.
The basement renovation. You are finishing a family room and the need for cool air goes up. Rather than adding a portable unit, you strengthen the central system, provided the blower keeps up with the airflow required.
What we ask of the blower
The coil does not move the air: the furnace blower does. If the airflow is insufficient, the coil gets too cold and can freeze over. That is why we check the blower, the plenum and the return air before confirming the size. A good coil on poor air circulation gives a poor result.
If the duct network is too restricted, we tell you and propose targeted fixes, such as a better-placed return grille, rather than changing equipment for no reason.
Quick answers
Does the furnace need to be replaced? No, it is still useful. Can I reuse the current outdoor unit? Generally not, because of R-32. What if the width doesn't match? We build an insulated transition on site.
A word on the condensate drain
The CAPFA3626C3 coil produces water every time it cools the humid air of a Montreal summer. It has to leave cleanly: a 3/4 in FNPT drain, with a primary and a secondary outlet to guard against any blockage. We take care with the slope, connect to a compliant discharge point and show you where to watch in case of clogging. It's a discreet detail that prevents water damage in humid summers.
Installation by AirGreen
AirGreen is a family-run heating and cooling company, in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work falls under RBQ licence 5645-9605-01. For this coil, we measure the furnace, check the blower and the panel, mount the cabinet, install the outdoor unit, braze the piping, pressure-test with nitrogen, pull a vacuum, connect the drain and the thermostat, then adjust the airflow.
To confirm before buying
- R-32 requires a compatible outdoor unit, installed at the same time.
- Published ratings apply to the certified match.
- The 21 in width and the blower must suit your furnace.
Financial help
Hydro-Québec programs apply to the complete system. We check the official list at quote time, based on the installation date.
Take the next step
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The CAPFA3626C3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Goodman outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.