GOODMAN CAPFA6030D3 Evaporator A-Coil | 5 Tons

In stock

The Goodman CAPFA6030D3 5-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCAPFA6030D3

5 tons60,000 BTU/h nominal
24-1/2 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedR-32
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCAPFA6030D3
ManufacturerGoodman
Size5 tons
Width24-1/2 in
RefrigerantR-32
MeteringPiston

CAPFA6030D3: 5 tons, 24-1/2 in, the largest coil in the CAPFA family

At the top of the Goodman CAPFA series, the CAPFA6030D3 is rated at 5 tons (60,000 BTU/h). Its cabinet measures 24-1/2 in wide, 30 in tall and 21 in deep. It runs on R-32 refrigerant, with a piston metering device, and mounts on a furnace or a blower cabinet, in upflow or downflow position.

It is a model for very large homes, for those that have grown through renovations, and for properties where a finished basement is added to two storeys. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

Two checks first: electricity and air

At this size, two points get settled before we talk about the model. First, the electrical service: the outdoor unit needs its own circuit, and the panel must be able to take it. Second, air distribution: the ducts, the returns and the blower must be able to deliver the airflow of a 5-ton system.

We assess both at the visit. If the air network is too tight, we propose corrections or, frankly, a system of two smaller zones, which might serve the home better than one big unit.

The "large" model within the series

  • Capacity: 5 tons, the highest; the CAPFA6030C3 comes next with 4 tons, then the three 3.5-ton models (CAPFA4226B3, C3 and D3).
  • Width: 24-1/2 in, the same as the three other D3 models, namely the CAPFA3022D3, the CAPFA3626D3 and the CAPFA4226D3.
  • Height: 30 in, like the CAPFA6030C3; the only two models to reach this height are the models of the 6030 family.

The CAPFA6030D3 is therefore the only coil in the series to combine the largest capacity and the largest width. If your home calls for 5 tons, there is no alternative in the range. If 4 tons is enough and your furnace is 21 in, look at the CAPFA6030C3.

Why a coil this size isn't always the best idea

Bigger doesn't mean better. A 5-ton unit in a home that only needs 3 or 4 tons starts and stops too often, dries the air poorly and leaves a clammy feeling. We prefer a load calculation to a rough rule, and we don't hesitate to recommend a smaller size when the numbers justify it.

The refrigerant circuit, on the technical side

The liquid arrives through the 3/8 in connection and passes through the piston. It then evaporates in the coil tubes and returns to the outdoor unit through the 7/8 in suction. The pan collects the condensation water and directs it to a 3/4 in FNPT drain, with a primary and a secondary outlet. An R-32 refrigerant sensor, designed for the whole life of the coil, watches for leaks.

A heat pump for the whole year

Connected to a heat pump, the coil heats in winter and cools in summer. The furnace keeps its blower and filters and takes over in deep cold according to a threshold that we set with you. In a large home, this redundancy offers real peace of mind.

What the published ratings are worth

  • The coil has no efficiency rating of its own. The ratings belong to the matched system and its AHRI number, which we confirm before ordering.
  • No R-32 match with this coil is listed with ENERGY STAR (dataset w7cv-9xjt, checked on 2026-11-26).
  • Goodman provides a 10-year limited parts warranty, with online registration within 60 days of installation (not required in Quebec).

CAPFA6030D3 features

  • type: cased evaporator coil;
  • nominal size: 5 tons (60,000 BTU/h);
  • refrigerant: R-32;
  • metering device: piston;
  • connections: 3/8 in liquid, 7/8 in suction;
  • drain: 3/4 in FNPT, primary and secondary;
  • dimensions: 24-1/2 × 30 × 21 in.

Over the course of a large job

A project of this scale always begins with a conversation. We visit the house, go upstairs, go down to the basement and talk about how you live in your home. We note where it's hot, where it's cold, where the noise is bothersome. Then we measure.

On installation day, the cabinet is mounted and sealed, the outdoor unit set in place, and the piping carefully brazed. The nitrogen test and the vacuum come before the system is opened, and we finish by adjusting the airflow room by room.

Questions we get

Is it enough for the whole house? That is the job of the load calculation. Do I have to change my panel? Maybe; we check. Is the furnace kept? Yes, as backup. What if my furnace's width differs? We build an insulated transition on site.

One system or two? The question we ask

In some large homes, a single 5-ton coil is not the best answer. A house stretched out lengthwise, or spread over several distinct levels, is sometimes tuned more finely with two mid-size systems, each serving its own zone. You gain in comfort, redundancy and flexibility: if one unit stops, the other keeps going.

Conversely, when the ducts are already well sized and the blower is robust, a single large system remains the simplest solution. We present both options with their advantages, then let you choose.

What the CAPFA6030D3 doesn't replace

A large coil corrects neither poor insulation nor leaky windows. Before sizing, we look at stray air leaks, the attic and the walls. Sometimes a few insulation fixes make it possible to choose a smaller size, which lightens both the initial bill and the operating cost.

AirGreen, your heating and cooling installer in Greater Montreal

AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is covered by RBQ licence 5645-9605-01. For this coil and its outdoor unit, we measure the furnace, check the blower and the electrical panel, mount the cabinet, install the outdoor unit, braze the piping, pressure-test with nitrogen, pull a vacuum, connect the drain and the thermostat and commission the system.

If you are torn between this model and a smaller size, ask us for the full load calculation: it details the heat gains room by room and makes the decision much easier to take.

To check before choosing

  • R-32 requires an outdoor unit with the same refrigerant, installed at the same time.
  • Published ratings valid for the certified match.
  • Electrical service, blower, ducts and clearance for a cabinet 24-1/2 in wide and 30 in tall.

Incentives

Hydro-Québec evaluates the complete system. We consult the official list at quote time, based on the installation date, and tell you what applies.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CAPFA6030D3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Goodman outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCAPFA6030D3
TypeCased evaporator coil
LineCAPFA
Nominal size5 tons (60,000 BTU/h)
RefrigerantR-32
Metering devicePiston
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D24-1/2 × 30 × 21 in
Model numberCAPFA6030D3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 24-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 5-ton Goodman coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.