GOODMAN CAPFA4226B3 Evaporator A-Coil | 3.5 Tons

In stock

The Goodman CAPFA4226B3 3.5-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCAPFA4226B3

3.5 tons42,000 BTU/h nominal
17-1/2 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedR-32
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCAPFA4226B3
ManufacturerGoodman
Size3.5 tons
Width17-1/2 in
RefrigerantR-32
MeteringPiston

When 3.5 tons must fit in 17-1/2 in: the CAPFA4226B3

Here is a configuration that raises eyebrows: a capacity of 3.5 tons (42,000 BTU/h) in the narrowest cabinet in the series. That is precisely what the CAPFA4226B3 offers, a Goodman cased evaporator A-coil running on R-32 refrigerant. It measures 17-1/2 in wide, 26 in tall and 21 in deep.

You find it in homes that need a lot of cooling but whose furnace is slim: large single-storey homes that are compact in width, cottages with a narrow plenum, townhouses with many rooms. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

What the capacity asks of the house

The more the capacity goes up, the more air has to circulate through the coil. At 3.5 tons, the system calls for more generous airflow than the 2.5-ton or 3-ton sizes. That airflow comes from the furnace blower, and it has to be able to deliver it without straining.

During the visit, we therefore measure three things: the blower capacity, the size of the plenum and the condition of the return air. A narrow plenum is not an obstacle in itself, but it requires careful attention to air distribution to avoid cold spots and noise.

Quick read of the four 3.5-ton and 3-ton models

  • CAPFA4226B3 (this one): 3.5 tons, 17-1/2 in;
  • CAPFA4226C3: 3.5 tons, 21 in;
  • CAPFA4226D3: 3.5 tons, 24-1/2 in;
  • CAPFA3626B3: 3 tons, 17-1/2 in, the same width with a lower capacity.

The 3-ton coil at 17-1/2 in is enough if your needs remain modest. This one is preferable if the house is large, has lots of glass or faces south. For even bigger homes, the series offers a 4-ton model at 21 in and a 5-ton model at 24-1/2 in.

Anatomy of the cabinet

The insulated casing of the CAPFA4226B3 encloses the A-coil, the drain pan and the connections. Two sloped faces meet at the top: air rises in the centre and passes through both sides. Upflow and downflow positions are provided by the manufacturer. The liquid connection is 3/8 in and the suction is 7/8 in, while the pan drains through a 3/4 in FNPT drain with a primary and a secondary outlet.

An R-32 refrigerant sensor, designed to last as long as the coil, watches for possible leaks.

Heat pump or air conditioner?

Both choices are possible with this coil. Paired with a central air conditioner, it only cools in summer. Paired with a heat pump, it also heats in winter through the existing ducts, with the furnace staying on as backup for deep cold.

The choice depends on your current heat source. If you heat with electricity, the heat pump offers a notable gain; if you heat with gas, we compare the two options with you before recommending one.

Efficiency, ENERGY STAR and warranty

  • The coil has no efficiency rating on its own; the ratings belong to the matched system and its AHRI number.
  • No R-32 match with this coil is listed with ENERGY STAR (dataset w7cv-9xjt, checked on 2026-11-26).
  • Goodman's limited warranty covers parts for 10 years, with online registration within 60 days (not required in Quebec).

CAPFA4226B3 features

  • nominal size: 3.5 tons (42,000 BTU/h);
  • refrigerant: R-32;
  • metering device: piston;
  • dimensions: 17-1/2 × 26 × 21 in;
  • connections: 3/8 in liquid and 7/8 in suction;
  • drain: 3/4 in FNPT, primary and secondary.

What we see in summer in a large house

In a cottage on the South Shore, the upstairs bedrooms are often the last to cool down. A well-sized coil, with a blower that delivers the required airflow, reduces those differences. If the bedrooms stay warm despite good equipment, the distribution is often the cause, and we can propose precise adjustments to the duct network.

A word on noise and comfort

A 3.5-ton system moves a lot of air. If the ducts are too tight, the rush of air becomes audible at the grilles. We therefore measure the cross-section of the main ducts and the returns, then recommend a blower speed that balances comfort and quiet. This work is all the more useful with a narrow cabinet, where the plenum can concentrate the airflow.

An extra return air on the upper floor, for example, can relieve the whole network without changing equipment.

When to choose a wider model instead

If your furnace measures 21 in or 24-1/2 in, the CAPFA4226C3 or the CAPFA4226D3 offers the same capacity without a transition. We always prefer a cabinet that matches the existing unit. The CAPFA4226B3 is the right choice when the 17-1/2 in width truly matches the furnace, not simply because it is the most compact.

A look at the energy bill

A coil well matched to its outdoor unit and to the blower works less hard for the same comfort. Conversely, a rough match makes the compressor run longer. That is one of the reasons we insist on the AHRI number: it attests that the components were tested together.

What people ask us most

Does R-32 refrigerant change anything for me? Mainly one point: the coil and the outdoor unit must share the same refrigerant, so they are replaced together.

What if the furnace is wide? We build an insulated transition on site, or we recommend a wider model in the series.

How we handle a narrow plenum

A 17-1/2 in plenum concentrates the air on a reduced surface. For the coil to work well, the air has to pass through it evenly, with no dead zones or currents that bypass it. We check that the cabinet is well centred, that the joints are tight and that the transition to the ducts doesn't create a choke point. Careful work at this spot translates into less noise and better cooling.

Complete installation by AirGreen

AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. We measure the furnace, check the blower and the panel, install the coil, install the outdoor unit, braze the piping, pressure-test with nitrogen, pull a vacuum, connect the drain and the thermostat, then adjust the airflow.

To confirm before placing your order

  • The coil and the outdoor unit must both be R-32.
  • Published ratings apply to the certified match.
  • The blower must deliver the airflow of 3.5 tons, and the furnace must be able to take the 17-1/2 in cabinet.

Incentives

Eligibility for Hydro-Québec programs depends on the complete system. We check the official list against the installation date and tell you what applies.

Estimate and financing

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CAPFA4226B3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Goodman outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCAPFA4226B3
TypeCased evaporator coil
LineCAPFA
Nominal size3.5 tons (42,000 BTU/h)
RefrigerantR-32
Metering devicePiston
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D17-1/2 × 26 × 21 in
Model numberCAPFA4226B3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3.5-ton Goodman coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.