TRANE 5TXCB004AS3HCA Evaporator A-Coil | 2 to 3.5 Tons

In stock

The Trane 5TXCB004AS3HCA 2 to 3.5-ton R-454B cased coil sits on your furnace and, matched with the Trane 5TWR7036A1 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model number5TXCB004AS3HCA

2 to 3.5 tons42,000 BTU/h nominal
17-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 216763806
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model number5TXCB004AS3HCA
ManufacturerTrane
Size2 to 3.5 tons
Width17-1/2 in
RefrigerantR-454B
MeteringTXV
Outdoor unit5TWR7036A1

5TXCB004AS3HCA: the 2 to 3.5 ton coil whose match is documented, with its AHRI numbers

Some coils are sold on the strength of a tonnage. This one rests on certification numbers that you can check yourself. The 5TXCB004AS3HCA, from the Trane 5TXC range, covers 2 to 3.5 tons (42,000 BTU/h nominal), measures 17-1/2 in wide and is matched with the Trane 5TWR7036A1 or 5TWX7036A1 outdoor unit. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

Learning to read an AHRI number

An AHRI number identifies a specific combination: this coil, this outdoor unit, this furnace or this air handler. It is the system's identity card. The published efficiency ratings and capacities are tied to that number, not to an individual part.

Why does this concern you? Because two quotes can show the same capacity and rest on different matches. Ask for the number, then look it up in the AHRI directory. We do it with you, before ordering.

The two systems published for this coil

First system. With the 5TWR7036A1 heat pump, the AHRI number is 216763806. Cooling is published at 31,800 BTU/h, and heating at 32,600 BTU/h at 47 °F. The ratings are SEER2 15.2 and HSPF2 8.5.

Second system. With the 5TWX7036A1 heat pump, the number is 216764349. Cooling reaches 32,200 BTU/h, heating 32,800 BTU/h at 47 °F, with SEER2 15.5 and HSPF2 8.5.

The gap is slim, and it comes from the outdoor unit model, not from the coil. We help you choose according to the house, the outdoor noise and the available location.

And ENERGY STAR, in all this?

Trane gives this combination as an ENERGY STAR certified example: the 5TXCB004 with the 5TWR7036A1 or 5TWX7036A1 heat pump, from the 17 Multi-Speed series, two-stage compressor, R-454B, certified for cold climates, SEER2 15.2 to 15.5 and HSPF2 8.5. The manufacturer also states that these coils are AHRI-certified with various split-system air conditioners and heat pumps (www.ahrinet.org, Trane COR-PSD003A-EN).

The measurements to know

  • Nominal size: 2 to 3.5 tons, or 42,000 BTU/h.
  • Dimensions (W × H × D): 17-1/2 × 22-1/2 × 21-1/2 in.
  • Net weight: 50 lb.
  • 3/8 in liquid connection, 7/8 in suction.
  • 3/4 in NPT condensate drain.
  • TXV metering device, R-454B refrigerant.
  • Position: upflow, downflow, horizontal left or right.

Note that the suction line goes up to 7/8 in here, while the two smallest models in the series stay at 3/4 in. The copper lines of the match are sized accordingly.

This model and its 17-1/2 in neighbours

Three coils share this width, and they differ by capacity:

  • 5TXCB003AS3HCA, 1.5 to 3 tons: a lower cabinet and a more modest starting size, with no specific outdoor unit named on the data sheet.
  • 5TXCB004AS3HCA, this one: 2 to 3.5 tons, with two certified matches.
  • 5TXCB006AS3HCA: 2 to 5 tons, for the house that asks for more, with three published matches.

Among the 21 in models, the 5TXCC005AS3HCA offers 2 to 4 tons. If your furnace is wider, that is an avenue to look at.

For which home?

The 2 to 3.5 ton range corresponds to a mid-sized house: a two-storey cottage, an extended bungalow, a deep semi-detached with a finished basement. It is neither the smallest nor the largest unit in the series, and that is precisely its strength. It leaves some margin if the house has been insulated or a room is added, without imposing an oversized unit.

An overly generous size causes short cycles: the air cools quickly, the machine stops before it has removed the moisture, and the house stays clammy. We calculate the home's load before setting the size, and we tell you honestly if it is better to aim for another model in the series.

Why the 7/8 in suction line matters

The suction line carries the refrigerant back to the compressor of the outdoor unit. Its diameter must match the coil and the unit outside. We do not leave this to chance: during installation, we connect the right piping, braze it with care, then pressurize it with nitrogen to check for leaks before pulling a vacuum.

If the existing line set is not the right diameter, it is replaced. It is a technical detail that avoids a lot of trouble later.

What the heat pump changes on the bill

An electric furnace turns each kilowatt-hour into an equal amount of heat. A heat pump moves outdoor heat to the inside: in mild weather, it supplies two to three times more than the electricity consumed. The colder it gets, the lower that efficiency falls, and the furnace takes over at the lowest temperatures. In summer, a single system cools every room and replaces the window units.

The coil at work

In the furnace plenum, the coil serves as the exchange surface. In summer, the refrigerant evaporates in it and removes heat and moisture from the air. In winter, with a heat pump, it gives up to that air the heat captured outdoors. The furnace keeps its blower and its filters, and takes over below the temperature threshold that we set together.

Installation and commissioning

AirGreen, a family-run heating and cooling company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01. For this system, the visit and installation cover:

  • measuring the furnace, checking the blower and the electrical panel;
  • installing the cabinet in the plenum, with an insulated transition if the width differs, and sealing the connections;
  • installing the outdoor unit, brazing, the nitrogen leak test and the vacuum;
  • connecting the condensate drain and the thermostat;
  • adjusting the airflow and handing over the explanations.

Simple maintenance for many years

After commissioning, maintenance comes down to very little: a clean filter, a condensate drain that runs freely and an outdoor unit kept clear of snow, leaves and branches. We show you each point when we hand over the system, and we remain available if a doubt arises during the season.

Questions to ask before signing

  • Which AHRI number appears on the quote?
  • Is the furnace really 17-1/2 in wide, or is a transition planned?
  • Does the blower deliver the system's airflow?
  • Is the outdoor unit on the same refrigerant, R-454B?

Comparing two quotes

Set them side by side and look for the same items: the AHRI number, the outdoor unit, the SEER2 and HSPF2 ratings, the detail of the electrical and piping work. A quote that specifies all of that compares well; a vague quote cannot be compared.

LogisVert incentive

The systems matched with this coil appear on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation. We check it on the official list at the time of the quote and we prepare the application with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Trane system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The 5TXCB004AS3HCA sits in the plenum of a furnace or air handler. Connected to the Trane 5TWR7036A1 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Trane 5TWR7036A1 outdoor unit
Certified systemMatched with the 5TWR7036A1, the system carries AHRI 216763806.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerTrane
Model5TXCB004AS3HCA
TypeCased evaporator coil
Line5TXC
Nominal size2 to 3.5 tons (42,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D17-1/2 × 22-1/2 × 21-1/2 in
Net weight50 lb
Matched outdoor unit5TWR7036A1, 5TWX7036A1
System AHRI number216763806, 216764349
System SEER2 / HSPF215.2 / 8.5
Model number5TXCB004AS3HCA
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
TRANE
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2 to 3.5-ton Trane coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.