TRANE 5TXCD008AS3HCA Evaporator A-Coil | 3 to 5 Tons

In stock

The Trane 5TXCD008AS3HCA 3 to 5-ton R-454B cased coil sits on your furnace and, matched with the Trane 5TWR7036A1 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model number5TXCD008AS3HCA

3 to 5 tons60,000 BTU/h nominal
24-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 216763913
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model number5TXCD008AS3HCA
ManufacturerTrane
Size3 to 5 tons
Width24-1/2 in
RefrigerantR-454B
MeteringTXV
Outdoor unit5TWR7036A1

5TXCD008AS3HCA: 24-1/2 in wide, 3 to 5 tons, for the widest furnaces in the Trane 5TXC range

Furnaces in large homes often have a wide plenum, sometimes wider than what coils of common size accept. In the 5TXC range, the letter D designates the greatest width: 24-1/2 in. The 5TXCD008AS3HCA is part of it. It covers 3 to 5 tons (60,000 BTU/h), measures 26-3/4 in high and weighs 64 lb. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

Is this coil made for my furnace?

The first answer lies in a tape measure. If your furnace plenum is 24-1/2 in wide, the coil fits it directly. If it is narrower, we build an insulated transition on site; but for a furnace of 21 in or less, a narrower coil from the series will generally be a better match, and you avoid unnecessary sheet-metal pieces.

Questions and answers about this model

Why the D rather than the C? Because the width follows the furnace. The 5TXCD008AS3HCA is the natural choice for a 24-1/2 in plenum.

Is it taller than the others? No. At 26-3/4 in, it is less tall than its sibling 5TXCD010AS3HCA, which is also 24-1/2 in. It therefore suits a room where height is at a premium.

Which outdoor unit? Three matches are published, detailed below.

The systems published for the 5TXCD008AS3HCA

  • With the 5TWR7036A1 (AHRI 216763913): cooling of 33,400 BTU/h, heating of 33,200 BTU/h at 47 °F, SEER2 16.0 and HSPF2 8.7.
  • With the 5TWR7048A1 (AHRI 218334933): cooling of 43,500 BTU/h, heating of 46,000 BTU/h at 47 °F, SEER2 16.0 and HSPF2 8.5.
  • With the 5TWX7036A1 (AHRI 216764416): cooling of 33,600 BTU/h, heating of 33,400 BTU/h at 47 °F, SEER2 16.0 and HSPF2 8.7.

The 5TWR7048A1 is the one that brings the most capacity, notably in heating. The two 7036 units are closer to each other. For a large house, heating capacity at 47 °F is an important criterion, but it is not the only one: the level of insulation, the windows and the number of floors count just as much.

Specifications

Cased coil, 5TXC range. Dimensions W × H × D: 24-1/2 × 26-3/4 × 21-1/2 in. Net weight of 64 lb. Nominal size of 60,000 BTU/h. Liquid connection of 3/8 in, suction of 7/8 in, condensate drain of 3/4 in NPT. TXV metering device and R-454B refrigerant. The manufacturer states that it is multi-position: upflow, downflow, horizontal left or right.

Where it sits in the series

  • Same 3 to 5 ton range in 21 in: the 5TXCC007AS3HCA and 5TXCC009AS3HCA, if the furnace is narrower.
  • Same width, more height: the 5TXCD010AS3HCA, which is matched with the 5TWV0X48A1 unit.
  • Different range: the 5TXCB006AS3HCA, 2 to 5 tons, at 17-1/2 in.

Between the two 24-1/2 in models, the available height and the desired outdoor unit make the difference: the 5TXCD008AS3HCA stays in the family of 7036 and 7048 units, while its sibling turns toward the 5TWV line.

The coil's role in the heat pump

Installed in the plenum, it makes the refrigerant work in contact with the circulating air. In summer, it removes heat and moisture. In winter, with a heat pump, it gives up to the air the heat captured outdoors. The furnace keeps its blower and remains the backup heat below the temperature threshold set with you.

Large homes have specific needs

In a large house, you think first of capacity, but it is often the electricity and the air distribution that decide. A properly sized outdoor unit calls for a circuit dedicated to it. A large duct network calls for a blower capable of overcoming its resistance. We assess both. It can happen that two smaller systems serve a very large house better, and we will tell you frankly.

One house, three seasons

In spring and fall, when temperatures stay mild, the heat pump handles the heating alone, and that is the period when the saving compared with pure electricity is felt most. An electric furnace converts each kilowatt-hour into an equal amount of heat; the heat pump, for its part, moves heat and delivers two to three times more in mild weather. When the cold sets in, that ratio shrinks and the furnace takes the main role again.

In summer, the same coil cools the floors and removes humidity. In a large house, the difference between a well-sized system and an oversized one is noticed right away: the first maintains an even coolness, the second leaves the air cold but sticky.

A visit that takes its time

For a large house on the South Shore or in Laval, the visit lasts longer than you might imagine. We go through every floor, we locate the main ducts, we look at where the air return is installed, we open the panel. We also note the possible location of the outdoor unit and its exposure to wind and snow. At the end, you receive a written quote, with the AHRI number of the proposed system.

Trane writes this

These coils are AHRI-certified with various split-system air conditioners and heat pumps (see www.ahrinet.org, Trane document COR-PSD003A-EN). ENERGY STAR certified example from the series: the 5TXCB004 with a 5TWR7036A1 or 5TWX7036A1 heat pump, on R-454B, certified for cold climates, SEER2 15.2 to 15.5 and HSPF2 8.5.

Our installation in five steps

  1. Measure the furnace, the blower and the electrical panel.
  2. Set the coil in the plenum and seal the duct joints.
  3. Install the outdoor unit, braze the piping, pressure-test with nitrogen and pull a vacuum.
  4. Connect the condensate drain and the thermostat.
  5. Commission the system, set the airflow and explain everything to you.

AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years, and its work is done under RBQ licence 5645-9605-01.

To consider before buying

  • R-454B requires an outdoor unit with the same refrigerant.
  • Published ratings belong to the certified system.
  • The 24-1/2 in width must match the furnace.
  • The blower must deliver the system's airflow.

One last check

Before the order, we go over the quote together: the coil model, the chosen outdoor unit, the AHRI number, the possible transition and the electrical work. Nothing should surprise you on installation day, and every line should be explainable in one sentence.

LogisVert incentive

The matched Trane system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation; we check it on the official list at the time of the quote and we prepare the application with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Trane system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The 5TXCD008AS3HCA sits in the plenum of a furnace or air handler. Connected to the Trane 5TWR7036A1 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Trane 5TWR7036A1 outdoor unit
Certified systemMatched with the 5TWR7036A1, the system carries AHRI 216763913.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerTrane
Model5TXCD008AS3HCA
TypeCased evaporator coil
Line5TXC
Nominal size3 to 5 tons (60,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D24-1/2 × 26-3/4 × 21-1/2 in
Net weight64 lb
Matched outdoor unit5TWR7036A1, 5TWR7048A1, 5TWX7036A1
System AHRI number216763913, 218334933, 216764416
System SEER2 / HSPF216.0 / 8.7
Model number5TXCD008AS3HCA
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 24-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
TRANE
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3 to 5-ton Trane coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.