TRANE 5TXCC009AS3HCA Evaporator A-Coil | 3 to 5 Tons
The Trane 5TXCC009AS3HCA 3 to 5-ton R-454B cased coil sits on your furnace and, matched with the Trane 5TWR7036A1 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model number5TXCC009AS3HCA
514 316-2973 · sales@airgreen.ca
Quick facts
The large size in 21 in: Trane 5TXCC009AS3HCA, a 30-3/4 in cabinet for the plenum with some height
Some furnaces are topped with a generous plenum: you could almost fit a cupboard in it. This is the kind of space where the 5TXCC009AS3HCA finds its place. Taller than its twin, the 5TXCC007AS3HCA, it measures 30-3/4 in high by 21 in wide, covers 3 to 5 tons (60,000 BTU/h) and weighs 70 lb. Our crews install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
Height as an advantage
A taller, heavier cabinet does not change the advertised nominal range, but it opens an extra door: the possibility of matching it with a larger outdoor unit, the 5TWR7048A1. It does not appear among the matches for the 5TXCC007AS3HCA.
The trade-off is that clearance is needed. We measure from the top of the furnace to the first obstacle before recommending this model.
The three certified systems
- Heat pump 5TWR7036A1, AHRI 216763909: 33,600 BTU/h of cooling, 32,800 BTU/h of heating at 47 °F, SEER2 16.0 and HSPF2 8.7.
- Heat pump 5TWR7048A1, AHRI 216764001: 43,000 BTU/h of cooling, 44,500 BTU/h of heating at 47 °F, SEER2 16.0 and HSPF2 9.0.
- Heat pump 5TWX7036A1, AHRI 216764411: the same capacities and the same ratings as the first.
The second system is the one that brings the most heat at 47 °F and the highest HSPF2 of the three. It is aimed at the house that spends a lot to heat. The other two are so alike that they are interchangeable on paper: the choice then depends on the installation.
Specification sheet
- Type: cased evaporator coil, 5TXC range.
- Nominal size: 3 to 5 tons, 60,000 BTU/h.
- Dimensions W × H × D: 21 × 30-3/4 × 21-1/2 in.
- Net weight: 70 lb.
- 3/8 in liquid connection, 7/8 in suction, 3/4 in NPT drain.
- TXV metering device, R-454B refrigerant.
- Multi-position: upflow, downflow, horizontal left or right.
Where it stands among its neighbours
In the 21 in column, there are three models: the 5TXCC005AS3HCA (2 to 4 tons, the lowest), the 5TXCC007AS3HCA (3 to 5 tons, medium height) and this one, the tallest. On the 24-1/2 in side, the 5TXCD010AS3HCA has the same height of 30-3/4 in, but it is wider and is matched with the 5TWV0X48A1 unit.
If your furnace is 21 in and the plenum is tall, the 5TXCC009AS3HCA is our starting choice. If the plenum is low, we fall back on its twin.
How the coil works
In the airflow path, the coil is the heat exchanger. In summer, the refrigerant evaporates in its tubes, absorbs heat and condenses moisture, which flows to the drain. In winter, with a heat pump, it delivers to the house air the heat captured outdoors. The furnace stays on as backup for the deep cold, according to a threshold that we set with you.
An example house
Imagine a large cottage in Boucherville or Blainville, with a living room with a cathedral ceiling, a finished basement and a tall-plenum furnace originally installed for a good-sized central air conditioner. The old air conditioner is at the end of its life, the winter bill weighs heavily, and the owners want to settle both issues at the same time.
The furnace heat pump answers that request. The coil slips onto the existing plenum, the ducts stay in place, and the furnace keeps its role as reinforcement. We establish the house's load room by room, then we choose the outdoor unit that meets it. In this kind of house, the match with the 5TWR7048A1 deserves a close look.
What the heat pump changes day to day
An electric furnace converts each kilowatt-hour into an equal amount of heat. A heat pump moves outdoor heat to the inside: in mild weather, it delivers two to three times more heat than the electricity consumed. The colder it gets, the lower that efficiency falls; the furnace then takes over. In summer, the same installation cools every room and dries the air.
Think about the electricity before thinking about the unit
An outdoor unit of this size requires a suitable circuit. We check the electrical panel, the available breaker and the distance between the panel and the unit's location. If an upgrade is needed, we tell you before the final quote, not after.
Weight and handling
At 70 lb, this cabinet is not a light package, and it is lifted up above a furnace. We plan for two installers, a stable support for the installation and clear access. We also protect the finished floor and we clean up the room at the end of the day. These are details you do not see on a data sheet, but they matter when you live in the house.
If the furnace is in a hard-to-reach corner, mention it when booking the appointment: we then bring the suitable equipment.
The job
A family-run heating and cooling company based in Montreal for more than fifteen years, AirGreen works under RBQ licence 5645-9605-01. For a system like this one, we measure the furnace and the blower, install the coil and seal the connections, set the outdoor unit on a pad or bracket, braze the piping, test for leaks with nitrogen, pull a vacuum, connect the drain and the thermostat, then we set the airflow and explain how it works.
What Trane publishes
Trane states that these coils are AHRI-certified with various split-system air conditioners and heat pumps (www.ahrinet.org, Trane document COR-PSD003A-EN). An ENERGY STAR certified example from the series involves the 5TXCB004 and the 5TWR7036A1 or 5TWX7036A1 heat pump, on R-454B, certified for cold climates, SEER2 15.2 to 15.5 and HSPF2 8.5.
Three mistakes to avoid
Choosing a coil on tonnage alone. Ordering before measuring the free height above the furnace. Accepting a quote where the system's AHRI number does not appear. Each of these mistakes is easy to fix before the order, and hard to fix after.
Checkpoints before purchase
- 21 in furnace, or a custom-built insulated transition.
- Enough free height for a 30-3/4 in cabinet.
- Blower capable of the required airflow.
- Outdoor unit on the same refrigerant, R-454B.
- AHRI number shown on the quote.
After commissioning
We give you a clear explanation of the thermostat, of the temperature threshold at which the furnace takes over and of the maintenance task to repeat. If a doubt comes to you later, a simple call is all we need to guide you.
LogisVert incentive
The matched Trane system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation. We check it on the official list at the time of the quote and we prepare the application with you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Trane system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The 5TXCC009AS3HCA sits in the plenum of a furnace or air handler. Connected to the Trane 5TWR7036A1 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Trane 5TWR7036A1 outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
TRANESee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3 to 5-ton Trane coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.