TRANE 5TXCC005AS3HCA Evaporator A-Coil | 2 to 4 Tons

In stock

The Trane 5TXCC005AS3HCA 2 to 4-ton R-454B cased coil sits on your furnace and, matched with the Trane 5TWR7024A1 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model number5TXCC005AS3HCA

2 to 4 tons48,000 BTU/h nominal
21 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 216763564
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model number5TXCC005AS3HCA
ManufacturerTrane
Size2 to 4 tons
Width21 in
RefrigerantR-454B
MeteringTXV
Outdoor unit5TWR7024A1

Trane 5TXCC005AS3HCA 48,000 BTU/h coil: the entry point for 21 in furnaces

At Trane, the letter C in the 5TXCC code marks a change in width: we move up to 21 in. The 5TXCC005AS3HCA is the first coil in this family, with a range of 2 to 4 tons and a nominal size of 48,000 BTU/h. Its designated partner is the 5TWR7024A1 outdoor unit. It is installed in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

A three-step reading

Step one: the furnace. Measure it, or send us a photo of its nameplate. If it is 21 in wide, this coil is a natural candidate.

Step two: the house. A range of 2 to 4 tons brings to mind a two-storey cottage, an extended country house or a deep bungalow. We calculate the load before promising a size.

Step three: the system. The coil is only worth as much as the outdoor unit that goes with it. That is why the next section talks about matches.

The published matches

Three combinations are published for this model:

  • the 5TWR7024A1 heat pump, AHRI number 216763564: cooling of 22,800 BTU/h, heating of 22,200 BTU/h at 47 °F, SEER2 16.0 and HSPF2 8.7;
  • the 5TWX7024A1, AHRI number 216764216, with the same capacities and the same ratings;
  • the 5TWX7036A1, AHRI number 216764386: 32,200 BTU/h in cooling, 32,800 BTU/h in heating at 47 °F, SEER2 15.5 and HSPF2 8.5.

Notice this: the 5TXCC005AS3HCA coil is the same in all three cases, but the system's capacity jumps with the outdoor unit chosen. That is proof that the coil's tonnage is only a frame; the outdoor unit adjusts the real capacity. The highest SEER2 and HSPF2 ratings go to the first two matches.

What is inside the cabinet

The coil is an A-coil housed in an insulated cabinet. Dimensions W × H × D: 21 × 22-1/2 × 21-1/2 in. Net weight: 52 lb. Connections of 3/8 in for the liquid line and 7/8 in for the suction line, condensate drain of 3/4 in NPT. TXV metering device, R-454B refrigerant. It is installed upflow, downflow or horizontal, with the connection on the left or the right.

Placing it in the series

  • Same 21 in width, higher range: the 5TXCC007AS3HCA and 5TXCC009AS3HCA, 3 to 5 tons, taller than this one.
  • Same height, narrower: the 5TXCB004AS3HCA, 2 to 3.5 tons, at 17-1/2 in.
  • Wider: the 5TXCD008AS3HCA and 5TXCD010AS3HCA, at 24-1/2 in.

Compared with the 5TXCB004AS3HCA, you gain exchange width and nominal range: the 5TXCC005AS3HCA goes up to 4 tons. Compared with the 3 to 5 ton models at 21 in, you stay in a more compact cabinet, and therefore one that is easier to fit.

What happens in the plenum

The house air is pushed by the furnace blower toward the coil. In summer, the refrigerant evaporates in the tubes, absorbs heat and removes moisture; the water goes to the drain. In winter, with a heat pump, the cycle reverses and the heat arrives from outside.

The furnace remains as backup and takes over below the temperature threshold that we set with you.

An example visit

Take a cottage in Terrebonne or Candiac, built in the nineties. The furnace is gas or electric, the basement is partly finished, and the mechanical room leaves reasonable clearance above the unit. We measure the plenum width, the clearance, the distance to the exterior wall for the unit and the panel capacity.

Often, the result is a written quote with the system's AHRI number, the detail of the transition to build and the layout plan for the unit outside. You then have a document that you can compare, line by line, with any other offer.

Choosing between the two 7024 units

The 5TWR7024A1 and 5TWX7024A1 heat pumps give the same capacities and the same published ratings with this coil. The choice is therefore made on other criteria: availability, location, configuration preferences and the terms of the offer. We explain what each one implies for your property.

Why not simply add an air conditioner?

You might think an ordinary central air conditioner is enough. It cools, yes, but it leaves the electric furnace to handle all the heating. A heat pump matched with this coil moves heat from outside to inside, and in mild weather it supplies two to three times more heat than the electricity it consumes. The colder it gets, the lower the efficiency falls; the furnace then steps in.

The installation in detail

AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years, holder of RBQ licence 5645-9605-01. The job always follows the same order:

  1. measuring the furnace, checking the blower and the electrical panel;
  2. installing the coil, sealing the duct connections, insulated transition if needed;
  3. installing the outdoor unit, brazed piping, nitrogen test, vacuum;
  4. connecting the condensate drain and the thermostat;
  5. commissioning, airflow adjustment and an explanation of how it works.

Summer humidity and maintenance

A well-sized coil runs cycles long enough to condense the moisture in the air. The pan collects the water, the drain carries it away, and the house feels cooler than a simple thermometer would suggest. To make that last, keep a clean filter and check from time to time that the drain runs freely. We show you where to look when we hand over the system.

Outside, let the unit breathe: clearance around the appliance, no snow piled against the fins, no leaves stuck on the grille.

What Trane says about these coils

The manufacturer states that these coils are AHRI-certified with various split-system air conditioners and heat pumps (www.ahrinet.org, Trane document COR-PSD003A-EN). It also cites an ENERGY STAR certified example: the 5TXCB004 with the 5TWR7036A1 or 5TWX7036A1 heat pump, on R-454B, certified for cold climates, SEER2 15.2 to 15.5 and HSPF2 8.5.

Before you decide

  • R-454B requires an outdoor unit with the same refrigerant, installed at the same time.
  • The ratings apply to the certified system, not to the coil alone.
  • The 21 in width must match the furnace, otherwise we build a transition.
  • The blower must deliver the system's airflow.

A word on the thermostat

The thermostat controls the whole setup: a single device to adjust for both seasons. We configure it with you, in particular the temperature threshold at which the furnace takes over, and we show you how to adjust it through the seasons.

LogisVert incentive

The matched Trane system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation. We check it on the official list at the time of the quote and we prepare the application with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Trane system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The 5TXCC005AS3HCA sits in the plenum of a furnace or air handler. Connected to the Trane 5TWR7024A1 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Trane 5TWR7024A1 outdoor unit
Certified systemMatched with the 5TWR7024A1, the system carries AHRI 216763564.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerTrane
Model5TXCC005AS3HCA
TypeCased evaporator coil
Line5TXC
Nominal size2 to 4 tons (48,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D21 × 22-1/2 × 21-1/2 in
Net weight52 lb
Matched outdoor unit5TWR7024A1, 5TWX7024A1, 5TWX7036A1
System AHRI number216763564, 216764216, 216764386
System SEER2 / HSPF216.0 / 8.7
Model number5TXCC005AS3HCA
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 21 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
TRANE
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2 to 4-ton Trane coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.