TRANE 5TXCB006AS3HCA Evaporator A-Coil | 2 to 5 Tons
The Trane 5TXCB006AS3HCA 2 to 5-ton R-454B cased coil sits on your furnace and, matched with the Trane 5TWR7036A1 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model number5TXCB006AS3HCA
514 316-2973 · sales@airgreen.ca
Quick facts
Trane 5TXCB006AS3HCA: a 2 to 5 ton coil, a slim 17-1/2 in wide and 26-3/4 in high
The 5TXCB006AS3HCA is the coil with the widest nominal range in the Trane 5TXC series: 2 to 5 tons, or 60,000 BTU/h. Its shape is that of a column, 17-1/2 in wide by 26-3/4 in high, and it is matched with three published outdoor units. It is meant for homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore who have a furnace of average width and a house with some scale.
Why a range of 2 to 5 tons?
This span does not mean the coil suits everything. It indicates that the same exchanger is matched with outdoor units of different capacities. It is the complete system, not the coil, that determines the real cooling and heating output.
A telling example: among the published matches, cooling varies from 22,000 BTU/h to 33,400 BTU/h. The number of tons printed on the coil is therefore only a reference point. Only the system's AHRI number tells you what you will get.
Three matches, three personalities
- With the 5TWR7036A1 (AHRI 216763871): cooling of 33,200 BTU/h, heating of 33,000 BTU/h at 47 °F, SEER2 16.0 and HSPF2 8.7.
- With the 5TWX7036A1 (AHRI 216764367): 33,400 BTU/h in cooling, 33,200 BTU/h in heating at 47 °F, the same ratings, SEER2 16.0 and HSPF2 8.7.
- With the 5TWV8X24A1 (AHRI 217179561): 22,000 BTU/h in cooling, 23,000 BTU/h in heating at 47 °F, SEER2 18.1 and HSPF2 8.5.
The third choice has the most modest capacity and the highest SEER2. It suits a house with a reduced load, for example one that is well insulated. The first two deliver more heat and more cooling. We guide you according to the calculated load, not according to the price of the unit.
Reading the numbers without being fooled
Heating is published at 47 °F: that is the reference outdoor temperature for the calculation. In deep cold, a heat pump's capacity drops, which is why the furnace stays on as backup. SEER2 describes cooling efficiency over the season, HSPF2 that of heating. These two ratings belong to the certified system, never to the coil alone.
If a quote cites a SEER2 without an AHRI number, ask the question. A figure without a number cannot be verified.
Dimensions and connections
Dimensions W × H × D: 17-1/2 × 26-3/4 × 21-1/2 in. Net weight of 55 lb. Liquid connection of 3/8 in, suction connection of 7/8 in, condensate drain of 3/4 in NPT. TXV metering device, R-454B refrigerant. The manufacturer states that the coil is multi-position: upflow, downflow, horizontal left or right.
The height of 26-3/4 in means you must check the space above the furnace. In a low mechanical room, another model may be more suitable.
Who are its closest neighbours?
At the same width, there are three models: the 5TXCB003AS3HCA, 1.5 to 3 tons, lower; the 5TXCB004AS3HCA, 2 to 3.5 tons, with two matches; and this one. The choice comes down to the volume of air to treat and the available height.
If your furnace is 21 in wide, the 5TXCC007AS3HCA offers a range of 3 to 5 tons at the same height of 26-3/4 in. If it is 24-1/2 in, look at the 5TXCD008AS3HCA.
What is the coil for, exactly?
It is the exchanger that cools or warms the house air. In summer, the cold refrigerant absorbs heat from the air passing through it, and the condensation flows out through the drain. In winter, with a heat pump, the coil returns to the air the heat captured outdoors. A single duct network serves both seasons.
Should you keep the furnace?
Yes, and it is an advantage. It keeps its blower, its filters and its heating elements. It provides backup heating when the outdoor temperature falls below the threshold that we set with you. An electric furnace converts each kilowatt-hour into an equal amount of heat; a heat pump supplies two to three times more in mild weather.
The case of a house with a finished basement
In a South Shore cottage whose basement has been finished, the furnace is often in a small utility room with a drop ceiling. The cabinet height then becomes the first question. Sometimes part of the ceiling has to be modified or a duct moved. We would rather see this at the visit, before the order, than on installation day.
In an open-plan North Shore house, it is rather the air distribution that will hold our attention: a large common room needs well-placed vents so that the cool air reaches the far end.
What we check at your home
- the furnace width, and the insulated transition to build if it differs from 17-1/2 in;
- the free height for a 26-3/4 in cabinet;
- the blower, which must deliver the system's airflow;
- the electrical panel, which must accommodate the outdoor unit's circuit;
- the location outside, sheltered from snow sliding off the roof.
Our installation method
A family-run heating and cooling company based in Montreal for more than fifteen years, AirGreen carries out its work under RBQ licence 5645-9605-01. For a system like this one, we place the coil in the plenum, seal the duct joints, set the outdoor unit on a pad or bracket, braze the piping, pressure-test with nitrogen and pull a vacuum. We then connect the condensate drain and the thermostat, then we set the airflow and explain the whole system to you.
What Trane publishes about these coils
Trane states that these coils are AHRI-certified with various split-system air conditioners and heat pumps (see www.ahrinet.org, Trane document COR-PSD003A-EN). An ENERGY STAR certified example from the series pairs the 5TXCB004 with the 5TWR7036A1 or 5TWX7036A1 heat pump, on R-454B, certified for cold climates, SEER2 15.2 to 15.5 and HSPF2 8.5.
One last planning tip
If you are planning future work, such as attic insulation, new windows or an addition, tell us before the quote. The home's load changes, and with it the choice of match among the three published. Better to think about it now than to adjust later.
To consider before buying
- R-454B refrigerant requires an outdoor unit with the same refrigerant.
- The ratings apply to the complete certified system.
- The AHRI number must appear on the quote.
LogisVert incentive
The matched Trane system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation; we check it on the official list at the quote and we prepare the application with you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Trane system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The 5TXCB006AS3HCA sits in the plenum of a furnace or air handler. Connected to the Trane 5TWR7036A1 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Trane 5TWR7036A1 outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
TRANESee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2 to 5-ton Trane coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.