YORK CTF60C5CGS1 Evaporator A-Coil | 5 Tons
The York CTF60C5CGS1 5-ton R-454B cased coil sits on your furnace and, matched with the York HH860E2S11 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCTF60C5CGS1
514 316-2973 · sales@airgreen.ca
Quick facts
CTF60C5CGS1: five tons in a 21 in. cabinet, for a narrow furnace
Many homes in the Greater Montreal area have a standard-size furnace tucked into a basement corner, yet a cooling demand that goes beyond what the smaller sizes can deliver. That is where the York CTF60C5CGS1 evaporator coil fits: a cased A-coil rated at 5 tons (60,000 BTU/h), whose 21 in. width lets it sit on a common-size furnace without much fuss.
We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. This page explains what the coil does, which outdoor unit it works with, who it suits and how it compares with the other models in the same series.
What an evaporator coil does, in two minutes
The coil is the heat exchanger that sits in the plenum, right above the furnace. The air from your home passes through it. When the outdoor unit sends cold refrigerant through its tubes, the air gives up its heat and its moisture: it comes out cool and drier, then is pushed into your existing ductwork. The water collected in the pan leaves through the drain.
If the outdoor unit is a heat pump, the cycle can reverse in winter. The same coil then becomes the heat source that warms the air being distributed. One piece of equipment, two seasons.
Its dimensions and installation
The CTF60C5CGS1 measures 21 in. wide by 33 in. high and weighs 64 lb net. It ships in an insulated cabinet, ready to sit on the furnace. The cabinet saves building a custom enclosure and improves the seal, which matters when you want the air to actually go through the coil rather than around it.
- Shape: A-coil, two sloped faces that meet at the top.
- Installation positions published by York: upflow or downflow.
- Metering device: TXV, which adjusts the refrigerant flow to the load.
- Connections: 3/8 in. for the liquid line, 7/8 in. for the suction line.
If your furnace is not exactly the same width, that is not an obstacle. We measure it during the visit and, if needed, build an insulated transition on site.
The two outdoor units it pairs with
This model is published with two outdoor units from the York HH8 series, which sets it apart from several of its neighbours in the series. Each one forms a certified system with its own AHRI number:
- HH860E2S11, AHRI 214606581: cooling 44,500 BTU/h, heating 46,000 BTU/h at 47 °F, SEER2 15.2, HSPF2 8.5;
- HH860E2S12, AHRI 218697654: cooling 44,500 BTU/h, heating 45,500 BTU/h at 47 °F, SEER2 15.2, HSPF2 8.1.
York specifies that the HH860E2S12 is matched with CT*60*G coils and that it is a two-stage unit. The HH8 series is an R-454B heat pump with a variable-speed compressor, ENERGY STAR certified for Canada and the United States. At quote time, we tell you which of the two pairings fits your project.
A word on efficiency ratings
The coil has no efficiency rating on its own. The SEER2, EER2 and HSPF2 ratings belong to the complete system: a specific coil, a specific outdoor unit, and an AHRI number that links them. To compare two quotes, always ask for that number. Two contractors talking about the "same" system may in fact be proposing different combinations.
The built-in leak detector
R-454B belongs to the A2L class of refrigerants. The CTF60C5CGS1 therefore comes with a factory-installed sensor mounted on the coil plate (code S) and connected to the RDS control board. If the concentration exceeds 15% of the LFL, the call to the compressor is cut and the indoor fan starts to circulate the air. This is a protection designed by the manufacturer, described in its installation manual 6356510-UIM-C-0824.
Five tons: is it really what you need?
The 5-ton size is the largest common residential size. It is meant for large homes, properties with a finished basement and those that have been extended over the years. Before choosing it, we check two things.
- The electrical service. It must be able to handle the outdoor unit's circuit.
- The airflow. This coil's rated airflow is 1,600 CFM. York indicates roughly 350 to 450 CFM per ton of outdoor unit, with an external static pressure of 0.2 to 0.6 in. w.c. The blower and the ductwork have to keep up.
If the house cannot support them, we will tell you frankly: two smaller systems sometimes serve better than one big one.
Choosing between the CTF60C5CGS1 and its neighbours
The series includes five 5-ton models, all A-coils, all cased, all R-454B and all with a TXV. The differences lie elsewhere:
- Width. The CTF60C5CGS1 and the CTF60C5CHS1 are 21 in. The CTF60D5CGS1, CTF60D5CHS1 and CTF60D5CJS1 are 24-1/2 in. If your furnace is narrow, the first two avoid a large transition.
- Height and weight. This model is the lightest in the series at 64 lb, and it stands 33 in. high. The CTF60C5CHS1, of the same width, is taller and heavier: it suits cases where the space above the furnace allows it.
- Pairings. This model accepts two outdoor units, the HH860E2S11 and the HH860E2S12, where the CTF60C5CHS1 lists only one.
What a heat pump changes day to day
An electric furnace turns every kilowatt-hour into an equal amount of heat. A heat pump instead moves heat from outside to inside: in mild temperatures, it delivers two to three times more than the electricity it uses. The colder it gets, the more that efficiency drops. The furnace therefore keeps its backup role and takes over below the threshold we set with you.
In summer, a single outdoor unit replaces window air conditioners and distributes cool air to every room. The drier air also makes July's humid heat easier to bear.
Our installation in Greater Montreal
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01. For this coil and its outdoor unit, the installation includes:
- measuring the furnace and checking the blower and the electrical panel;
- installing the coil in the plenum and sealing the duct connections;
- installing the outdoor unit, brazed piping, a nitrogen leak test and evacuation;
- connecting the condensate drain and the thermostat;
- commissioning, airflow adjustment and an explanation of how everything works.
Before you buy
- The coil uses R-454B: it is paired with an outdoor unit using the same refrigerant, installed at the same time. Keeping an old air conditioner is not an option.
- The published ratings apply to the certified pairing, not to the coil alone.
- The furnace must have the right width and blower. We confirm this during the visit.
- The manufacturer offers a 10-year limited parts warranty.
LogisVert rebate
The matched York system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it against the official list at quote time and prepare the application with you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CTF60C5CGS1 sits in the plenum of a furnace or air handler. Connected to the York HH860E2S11 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the York HH860E2S11 outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
YORKSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 5-ton York coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.