YORK CTF60C5CHS1 Evaporator A-Coil | 5 Tons
The York CTF60C5CHS1 5-ton R-454B cased coil sits on your furnace and, matched with the York HH860E2S11 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCTF60C5CHS1
514 316-2973 · sales@airgreen.ca
Quick facts
York CTF60C5CHS1: the narrow, tall 5-ton coil, made for a 21 in. furnace
Some furnaces are narrow but leave plenty of room above. For that kind of installation, the shape of the CTF60C5CHS1 makes sense: 21 in. wide, 37-1/4 in. high, a cased A-coil from the York CTF line, rated at 5 tons (60,000 BTU/h). Rather than growing wider, it grows taller, and it offers a heat-exchange surface that the shorter models do not have.
AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Here is what you need to know before putting it on your quote.
What sets it apart: its height and weight
The CTF60C5CHS1 weighs 70 lb net and measures 21 × 37-1/4 in. It has the same width as the CTF60C5CGS1, but a greater height. Its rated airflow is 1,800 CFM; its shorter twin lists a lower rated airflow.
In practical terms, the question to ask before buying is not "will it fit on the furnace?" but "how much space is left between the top of the furnace and the ceiling of the utility room, or the first duct junction?" The plenum must be able to take the cabinet, and the setup must stay accessible for future maintenance. We take that measurement during the visit, along with the furnace width.
How the coil works in your home
Air from the house is drawn in by the furnace blower, rises to the centre of the A, then passes through the coil's two sloped faces. There, it meets the liquid refrigerant sent by the outdoor unit and cools down. The moisture it carried condenses, drops into the pan and runs to the drain. The dry, cool air then goes back out through your ducts.
With a heat pump, the path reverses in winter: it is the hot refrigerant that gives up its heat to the air. Your furnace and its heating elements stay in place for the coldest days.
The certified system with this coil
For the CTF60C5CHS1, York publishes a single pairing:
- outdoor unit HH860E2S11, AHRI number 214606531;
- cooling 54,000 BTU/h;
- heating 55,000 BTU/h at 47 °F;
- SEER2 15.2 and HSPF2 8.1.
A single pairing means a simpler quote: there is no need to choose between two outdoor units. The HH8 series is an R-454B heat pump with a variable-speed compressor, ENERGY STAR certified for Canada and the United States. York notes that most coil-only pairings in this series are certified for cold climates, but that those using a 60 H-type coil are not, which explains this system's HSPF2 8.1 rating.
A useful reminder: the coil has no efficiency rating on its own. It is the system ratings, linked by the AHRI number, that are used to compare quotes and to put together a rebate application.
Technical sheet summary
- type: cased evaporator A-coil;
- size: 5 tons (60,000 BTU/h), refrigerant R-454B;
- dimensions (W × H × D): 21 × 37-1/4 in., net weight 70 lb;
- connections: 3/8 in. liquid, 7/8 in. suction;
- metering device: TXV;
- positions: upflow or downflow;
- rated airflow: 1,800 CFM;
- manufacturer's warranty: 10-year limited parts warranty.
A word on noise, comfort and adjustment
A taller coil gives the air passing through it more surface, but it does not settle comfort on its own. What counts is the balance between the blower's airflow, the cleanliness of the filter and the condition of the ducts. At commissioning, we adjust the airflow so that the air does not whistle at the grilles and the far rooms get their share. If you notice a difference from one room to another later on, adjusting the registers is often enough.
Think about access too: a tall cabinet must stay easy to open or move aside if a technician has to clean the condensate pan. It is a detail we look at with you during the visit, before fixing the unit's final position.
Safety: the A2L leak sensor
R-454B is an A2L-class refrigerant, which requires a detection device. On this model, the sensor is factory-installed (code S) on the coil plate and wired to the RDS control board. Above 15% of the LFL, the call to the compressor is cut and the indoor fan starts. This logic is described in the manufacturer's manual 6356510-UIM-C-0824.
Before choosing this size: three questions
- Is your home big enough? The 5-ton size is the largest common residential size, meant for large homes, finished basements and extensions. If your needs are more modest, a smaller size will cost less to install and to run.
- Can your electrical service keep up? The outdoor unit's circuit must have room there.
- Can your ducts breathe? York indicates roughly 350 to 450 CFM per ton of outdoor unit, with an external static pressure of 0.2 to 0.6 in. w.c. A narrow or overly winding duct system chokes the system, whatever the coil.
The CTF60C5CHS1 versus its four neighbours
In this series of five 5-ton coils, all A-coils, all cased, with R-454B and a TXV, the choice comes down to three criteria.
- Width of 21 in. or 24-1/2 in. This model and the CTF60C5CGS1 are the two narrow ones.
- Height. Compared with the CTF60C5CGS1, which is shorter and lighter, the CTF60C5CHS1 adds height, weight and a higher rated airflow. If the plenum is low, the CTF60C5CGS1 is the natural alternative.
- Pairing. Here, a single outdoor unit: the HH860E2S11. The CTF60C5CGS1 accepts two.
The CTF60D5CGS1, CTF60D5CHS1 and CTF60D5CJS1 models are the 24-1/2 in. versions. They serve wider furnaces.
Heat pump and furnace: who works when
An electric furnace produces an amount of heat equal to the energy it consumes. A heat pump moves existing heat: in mild temperatures, it delivers two to three times more than the electricity it uses. That efficiency decreases with the cold, which is why the furnace stays on as backup. The switchover threshold between the two is set with you.
The installation, step by step
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01.
- measuring the furnace, checking the blower and the electrical panel;
- installing the coil in the plenum, adding a transition if needed, sealing the connections;
- installing the outdoor unit, brazed piping, nitrogen test, evacuation;
- connecting the drain and the thermostat;
- commissioning, airflow adjustment, walk-through at your home.
LogisVert rebate
The matched York system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check it against the official list at quote time and prepare the application with you.
Next step: a visit to your home
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CTF60C5CHS1 sits in the plenum of a furnace or air handler. Connected to the York HH860E2S11 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the York HH860E2S11 outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
YORKSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 5-ton York coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.