YORK CTF60D5CJS1 Evaporator A-Coil | 5 Tons

In stock

The York CTF60D5CJS1 5-ton R-454B cased coil sits on your furnace and, matched with the York HH860E2S11 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCTF60D5CJS1

5 tons60,000 BTU/h nominal
24-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 214606578
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCTF60D5CJS1
ManufacturerYork
Size5 tons
Width24-1/2 in
RefrigerantR-454B
MeteringTXV
Outdoor unitHH860E2S11

CTF60D5CJS1: same footprint as the D5CGS1, but a single pairing and an HSPF2 8.5 rating

On paper, the CTF60D5CJS1 looks a lot like its neighbour the CTF60D5CGS1: the same 24-1/2 in. width, the same 32-3/4 in. height, the same insulated cabinet, the same 5-ton (60,000 BTU/h) R-454B A-coil. Yet it is not the same product. It weighs 73 lb net, it is published with a single certified system, and that system shows capacities and a heating rating of its own. This page helps you see where those differences lie.

AirGreen installs this coil in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

The certified system, figure by figure

York matches the CTF60D5CJS1 with a single outdoor unit:

  • HH860E2S11, AHRI number 214606578;
  • cooling 52,000 BTU/h;
  • heating 55,000 BTU/h at 47 °F;
  • SEER2 15.2, HSPF2 8.5.

What stands out is the combination of 55,000 BTU/h of heating and an HSPF2 8.5 rating. In this series, other pairings reach similar heating, but with an HSPF2 8.1 rating. York also specifies that most pairings in the HH8 series are certified for cold climates, with a few exceptions. We confirm with you the exact status of the system we propose.

To restate the principle: the coil has no efficiency rating on its own. SEER2, EER2 and HSPF2 describe a complete system, linked by its AHRI number. That is the number to ask for when comparing quotes.

D5CGS1 or D5CJS1: how to decide

If you are torn between these two 24-1/2 in. models, here is what matters:

  • Dimensions. Identical: 24-1/2 × 32-3/4 in. If the furnace accepts one, it accepts the other.
  • Weight. The CTF60D5CJS1 is heavier. The difference is modest, but you feel it when handling it down a basement staircase.
  • Pairings. The CTF60D5CGS1 is published with two outdoor units, the HH860E2S11 and the HH860E2S12. The CTF60D5CJS1 has only one, the HH860E2S11.
  • Cooling capacity. The CTF60D5CJS1 system publishes a higher capacity than the CTF60D5CGS1 systems.

In other words, the CTF60D5CGS1 offers more choice of pairing; the CTF60D5CJS1 offers a single system with a higher cooling capacity.

And against the other models in the series

The CTF60D5CHS1 is taller and heavier than this one. The CTF60C5CGS1 and CTF60C5CHS1 are 21 in. models, to choose when the furnace is narrow. All five are cased A-coils, using R-454B, with a TXV metering device.

Who is this model designed for?

It suits the homeowner whose furnace is wide, whose plenum is not very tall, and who prefers a single, clear pairing over a choice between two outdoor units. It is also a good candidate when the house is large, with a finished basement and several bedrooms upstairs, and the summer cooling has to cover a large area.

In a suburban home in Laval or on the South Shore, with a generously sized furnace, the CTF60D5CJS1 goes in without a transition. In a Montreal plex where the furnace is narrower, we look instead at the 21 in. models, or we build an insulated transition on site.

In every case, we do not sell you the biggest size on principle. We calculate what your home can really use, then propose the coil and outdoor unit that match.

CTF60D5CJS1 technical sheet

  • type: cased evaporator coil from the CTF line;
  • size: 5 tons (60,000 BTU/h), refrigerant R-454B;
  • dimensions (W × H × D): 24-1/2 × 32-3/4 in., net weight 73 lb;
  • connections: 3/8 in. liquid, 7/8 in. suction;
  • metering device: TXV;
  • positions: upflow or downflow;
  • rated airflow: 1,800 CFM;
  • manufacturer's warranty: 10-year limited parts warranty.

What the coil does, in practice

Installed in the plenum of a furnace or blower cabinet, it receives refrigerant from the outdoor unit. The house air, pushed by the blower, passes through its two faces, cools down and dries out. The condensation water is collected in the pan, then removed through the drain. With a heat pump, the cycle reverses in winter and the coil heats the air, through the same ducts.

The furnace keeps its place: it serves as backup when the outdoor temperature falls below the threshold we set with you.

A refrigerant leak? The coil keeps watch

R-454B is an A2L refrigerant. This model therefore ships with a factory-installed sensor (code S), attached to the coil plate and wired to the RDS control board. Above 15% of the LFL, the call to the compressor is cut and the indoor fan is started. Full operation is described in manual 6356510-UIM-C-0824.

What you will not see, but what matters

A well-installed coil disappears into the plenum and is forgotten. What makes it last are the invisible details: connections brazed cleanly under nitrogen, a complete evacuation before the valves are opened, a drain with a steady slope and a perfectly sealed cabinet. It is those steps, not the specification sheet alone, that determine whether the system keeps its promises ten years from now.

Before choosing a system this size

The 5-ton size is the largest common residential size; it is meant for large homes, finished basements and extensions. Two points are checked first: the electrical service, which must handle the outdoor unit's circuit, and the air distribution. York indicates roughly 350 to 450 CFM per ton of outdoor unit, with an external static pressure of 0.2 to 0.6 in. w.c.

If the house is not ready, we say so plainly, and we discuss two smaller systems.

On comfort, an electric furnace produces as much heat as the energy it consumes, whereas a heat pump moves heat: in mild weather, it provides two to three times more than the electricity used. That efficiency decreases when it gets very cold.

Installation by AirGreen

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, under RBQ licence 5645-9605-01.

  • measuring the furnace, checking the blower and the electrical panel;
  • installing the coil, an insulated transition if needed, sealing the connections;
  • outdoor unit, brazed piping, nitrogen test, evacuation;
  • connecting the drain and the thermostat;
  • commissioning and airflow adjustment.

The coil is paired with an outdoor unit using the same refrigerant, installed at the same time: an old air conditioner is not kept.

Finally, we give you a written quote that names the coil, the outdoor unit and the AHRI number, so that you can compare without ambiguity.

LogisVert rebate

The matched York system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it against the official list at quote time and prepare the application with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CTF60D5CJS1 sits in the plenum of a furnace or air handler. Connected to the York HH860E2S11 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the York HH860E2S11 outdoor unit
Certified systemMatched with the HH860E2S11, the system carries AHRI 214606578.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerYork
ModelCTF60D5CJS1
TypeCased evaporator coil
LineCTF
Nominal size5 tons (60,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Airflow1,800 CFM
Dimensions W × H × D24-1/2 × 32-3/4 in
Net weight73 lb
Matched outdoor unitHH860E2S11
System AHRI number214606578
System SEER2 / HSPF215.2 / 8.5
Model numberCTF60D5CJS1
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 24-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
YORK
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 5-ton York coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.