YORK CTF60D5CGS1 Evaporator A-Coil | 5 Tons

In stock

The York CTF60D5CGS1 5-ton R-454B cased coil sits on your furnace and, matched with the York HH860E2S11 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCTF60D5CGS1

5 tons60,000 BTU/h nominal
24-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 214606579
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCTF60D5CGS1
ManufacturerYork
Size5 tons
Width24-1/2 in
RefrigerantR-454B
MeteringTXV
Outdoor unitHH860E2S11

CTF60D5CGS1: the 24-1/2 in. York coil, compact in height, for a wide furnace

A wide furnace, a low plenum, a big house to cool: the York CTF60D5CGS1 evaporator coil was designed for that kind of combination. At 24-1/2 in. wide and 32-3/4 in. high, this cased 5-ton (60,000 BTU/h) A-coil takes up more width than the 21 in. models, but it stays short in height, which makes installation easier when the clearance above the furnace is limited.

We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Read what follows before comparing quotes.

Frequently asked questions about this model

Can it heat, or only cool?

That depends on the outdoor unit. Paired with a heat pump, it cools in summer and heats in winter. With a central air conditioner, it only provides cooling.

Can I keep my current air conditioner?

Generally, no. The coil runs on R-454B and must be paired with the outdoor unit specified by the manufacturer. We install the complete system.

My furnace is a different width. What can be done?

We measure it and, if needed, build an insulated transition on site.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the threshold set with you.

What is inside the cabinet

The CTF60D5CGS1 ships in an insulated cabinet, ready to sit on the furnace or on a blower cabinet. Here are the essentials of its specification sheet:

  • dimensions (W × H × D): 24-1/2 × 32-3/4 in.;
  • net weight: 66 lb;
  • rated airflow: 1,800 CFM;
  • connections: 3/8 in. for the liquid line, 7/8 in. for the suction line;
  • metering device: TXV;
  • installation positions: upflow or downflow;
  • manufacturer's warranty: 10-year limited parts warranty.

The A-coil forms an inverted roof in the plenum. The air rises to the centre, passes through the two faces and leaves cooled. This shape is the most common on upflow furnaces.

Two certified pairings, two heating profiles

Like the CTF60C5CGS1, this model is published with two outdoor units from the York HH8 series. The ratings belong to the systems, not to the coil alone:

  • HH860E2S11, AHRI 214606579: cooling 44,500 BTU/h, heating 46,000 BTU/h at 47 °F, SEER2 15.2, HSPF2 8.5;
  • HH860E2S12, AHRI 218697633: cooling 44,500 BTU/h, heating 45,500 BTU/h at 47 °F, SEER2 15.2, HSPF2 8.1.

Both offer the same cooling capacity. The first shows a somewhat higher HSPF2 and slightly more heating at 47 °F. The second is the two-stage unit that York matches with CT*60*G coils. York also specifies that most of these pairings are certified for cold climates, with a few exceptions noted in its documents. We confirm the exact AHRI number for you before ordering.

Why talk about the AHRI number?

Because it is the only reliable way to compare two offers. A coil has no efficiency rating of its own; SEER2, EER2 and HSPF2 attach to a specific combination of a coil and an outdoor unit. Without the number, you are comparing promises. With it, you are comparing tested systems. It is also the number used for rebate programs.

Choosing within the series: where does the D5CGS1 stand?

The five 5-ton CTF coils share the A shape, the cabinet, R-454B and the TXV. Here is how to place this one:

  • Against the 21 in. models (CTF60C5CGS1 and CTF60C5CHS1): it is several inches wider. Choose it if the furnace is wide, to avoid a transition that narrows the passage.
  • Against the CTF60D5CHS1 and CTF60D5CJS1, of the same width: the CTF60D5CHS1 is taller and heavier; the CTF60D5CJS1 has the same 24-1/2 × 32-3/4 in. dimensions but is heavier than this one.
  • Pairing: the CTF60D5CGS1 is one of the two models in the series that list two outdoor units, along with the CTF60C5CGS1.

Planning the installation when the furnace is wide

A wide furnace has an advantage: the air moves across a larger section, which limits the speed at the internal grilles. But it also means checking that the cabinet sits flat, that the plenum opening is clear and that the condensate drain can run down with a steady slope. We check those three points during the visit. We also look at where the refrigerant lines will run between the coil and the outdoor unit, to avoid pointless detours in the basement.

In homes in Laval or on the North Shore where the service area is open, installation is generally done without reworking the ducts. In older bungalows in Montreal or Longueuil, the utility room can be tight: that is when this model's reduced height makes the difference.

The leak sensor that comes with R-454B

This refrigerant is A2L class. York therefore fits a factory-installed sensor (code S) on the coil plate, connected to the RDS control board. Above 15% of the LFL, the call to the compressor is cut and the indoor fan turns on. The procedure is described in manual 6356510-UIM-C-0824.

What it means for your bill and your comfort

An electric furnace converts every kilowatt-hour into an equal amount of heat. A heat pump, on the other hand, moves outdoor heat into the house: in mild weather, it delivers two to three times more than the electricity it consumes. That efficiency drops with the cold, hence the furnace's backup role. In summer, the same equipment replaces window air conditioners and dries the air.

At this size, two checks are essential: the electrical service, which must handle the outdoor unit's circuit, and the air distribution. York indicates roughly 350 to 450 CFM per ton of outdoor unit and an external static pressure of 0.2 to 0.6 in. w.c. If the house is not suited to it, we say so frankly: two smaller systems may be a better fit.

Our work, from the visit to commissioning

AirGreen is a family-owned heating and cooling company, in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work.

  • measuring the furnace, checking the blower and the panel;
  • installing the coil in the plenum and sealing the connections;
  • installing the outdoor unit, brazed piping, nitrogen test, evacuation;
  • connecting the condensate drain and the thermostat;
  • airflow adjustment and an explanation of how everything works.

Before you order

  • R-454B requires an outdoor unit using the same refrigerant, installed at the same time.
  • The published ratings apply to a specific matched system.
  • The furnace width and the blower capacity are confirmed on site.

LogisVert rebate

The matched York system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it against the official list at quote time and prepare the application with you.

Get a written quote

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CTF60D5CGS1 sits in the plenum of a furnace or air handler. Connected to the York HH860E2S11 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the York HH860E2S11 outdoor unit
Certified systemMatched with the HH860E2S11, the system carries AHRI 214606579.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerYork
ModelCTF60D5CGS1
TypeCased evaporator coil
LineCTF
Nominal size5 tons (60,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Airflow1,800 CFM
Dimensions W × H × D24-1/2 × 32-3/4 in
Net weight66 lb
Matched outdoor unitHH860E2S11, HH860E2S12
System AHRI number214606579, 218697633
System SEER2 / HSPF215.2 / 8.5
Model numberCTF60D5CGS1
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 24-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
YORK
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 5-ton York coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.