YORK CTF60D5CHS1 Evaporator A-Coil | 5 Tons
The York CTF60D5CHS1 5-ton R-454B cased coil sits on your furnace and, matched with the York HH860E2S11 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCTF60D5CHS1
514 316-2973 · sales@airgreen.ca
Quick facts
York CTF60D5CHS1: the biggest coil in the series, 24-1/2 in. wide and 74 lb
In the family of 5-ton CTF coils, the CTF60D5CHS1 is the most imposing: 24-1/2 in. wide, 37-1/4 in. high, 74 lb net. It is a cased A-coil rated at 5 tons (60,000 BTU/h), running on R-454B refrigerant. It targets the large furnace, the large plenum and the large house, where you want a big heat-exchange surface and a certified high-capacity system.
This page is written for homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore who are comparing several York coils and want to understand what really changes from one model to the next.
What you gain with a big cabinet
A wider, taller cabinet holds a more generous coil. The CTF60D5CHS1 lists a rated airflow of 1,800 CFM. It ships insulated, ready to sit on the furnace, with a TXV metering device that adjusts the refrigerant feed. The connections are 3/8 in. for the liquid line and 7/8 in. for the suction line, and the manufacturer publishes two installation positions: upflow or downflow.
This size does come at a cost in space, though: it needs room, in both width and height, and the plenum must be able to carry the cabinet's weight.
The checklist before the visit
- Furnace width. Ideally 24-1/2 in. If it is narrower, we build an insulated transition on site.
- Available height. The cabinet measures 37-1/4 in. It must fit under the obstacles in the utility room, beams and pipes included.
- Strength of the support. At 74 lb, the cabinet rests on the furnace: we check that its top is flat and in good condition.
- Electrical service. The outdoor unit's circuit must have room there.
- Blower and ducts. They must deliver the airflow the system calls for.
A single pairing, high ratings
York publishes a single certified system for this coil:
- outdoor unit HH860E2S11;
- AHRI number 214606580;
- cooling 54,000 BTU/h;
- heating 55,000 BTU/h at 47 °F;
- SEER2 15.2, HSPF2 8.1.
The HH8 series is an R-454B heat pump with a variable-speed compressor, ENERGY STAR certified for Canada and the United States. In this pairing, the published cooling and heating capacities are higher than those of the systems matched with the CTF60C5CGS1 and CTF60D5CGS1: that is one of the arguments for choosing it if your home is large.
An important point: the coil has no efficiency rating on its own. SEER2, EER2 and HSPF2 are read from the complete system, linked by its AHRI number.
The CTF60D5CHS1 compared with its neighbours
- Against the CTF60D5CGS1 and CTF60D5CJS1 (same width): they are lower. If the plenum is limited in height, one of those two models is a better fit.
- Against the CTF60C5CHS1 (same 37-1/4 in. height, 21 in. width): they have the same vertical profile, but this one is wider. The choice depends on the furnace width.
- Against the CTF60C5CGS1: this is the opposite, the narrowest and lightest in the series.
All share the A shape, the cabinet, the TXV and R-454B; all have the HH860E2S11 as their main outdoor unit. The CTF60D5CHS1 is the heaviest of the group.
Three scenarios where this model makes sense
The large multi-storey house. A two-storey home with a finished basement calls for a lot of cool air in July. A well-ducted 5-ton system avoids putting window air conditioners in the upstairs bedrooms.
The electric furnace to replace. You heat with electricity and the furnace is wide. By adding a heat pump, you keep your ducts, your blower and your thermostat, and you reduce reliance on the heating elements.
The old central air conditioner on its last legs. Because R-454B does not mix with the old refrigerant, we replace the outdoor unit and the coil together. It is a chance to move to a complete certified system, with its AHRI number.
Maintenance: what stays simple
A large coil does not mean complicated maintenance, quite the opposite.
The coil asks almost nothing of a homeowner. Change the filter as your furnace recommends, keep the registers clear and check from time to time that the condensate drain flows well. A technician can inspect the pan and the sensor during a routine service visit. With a big cabinet like this one, we leave enough clearance for that inspection to stay easy.
How the coil works in your home
The blower sends the house air to the centre of the A. It passes through the two faces and gives up its heat to the cold refrigerant. The moisture condenses in the pan and runs out through the drain. In summer, you get cool, dry air in every room served by your ducts.
With a heat pump, the cycle reverses in winter. The furnace keeps its heating elements: it takes over below the temperature threshold we set with you.
The R-454B leak sensor
R-454B is an A2L refrigerant. The coil includes a factory-installed sensor (code S), mounted on the coil plate and wired to the RDS control board. If the concentration exceeds 15% of the LFL, the call to the compressor is cut and the indoor fan starts. See the manufacturer's manual 6356510-UIM-C-0824.
Do you really need five tons?
The 5-ton size is the largest common residential size. It suits large homes, finished basements and extensions. It is mostly justified when the air distribution can keep up: York mentions roughly 350 to 450 CFM per ton of outdoor unit, with an external static pressure of 0.2 to 0.6 in. w.c. If your ducts are too restrictive, we will tell you, and we then talk about two smaller systems.
An electric furnace produces as much heat as the energy it consumes. A heat pump moves heat: in mild weather, it provides two to three times more than the electricity it uses. That efficiency drops with the cold, hence the furnace's backup role.
Our installation
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01.
- measuring the furnace, checking the blower and the electrical panel;
- installing the cabinet in the plenum and sealing the connections;
- installing the outdoor unit, brazed piping, nitrogen test, evacuation;
- connecting the drain and the thermostat;
- commissioning, airflow adjustment, explanations.
The manufacturer offers a 10-year limited parts warranty.
LogisVert rebate
The matched York system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it against the official list at quote time and prepare the application with you.
Take the next step
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CTF60D5CHS1 sits in the plenum of a furnace or air handler. Connected to the York HH860E2S11 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the York HH860E2S11 outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 24-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
YORKSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 5-ton York coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.
