2-Zone Heat Pump ARCOAIRE D5CMHA | 30,000 BTU - R454B

In stock
SKU: D5CMHAH30EAK
30,000BTU/h · 2 heads
−30 °Cheats down to
$4,200LogisVert, indicative
ENERGY STAR® cold climateOptional Wi-FiR-454BUp to 4 heads
Talk to a technician · 514 316-2973
Outdoor unit D5CMHAH30EAKPossible indoor models D5FSHAH06XAK, D5FSHAH09XAK, D5FSHAH12XAK, D5FSHAH18XAKAHRI 215357141· ENERGY STAR 3722940
In short

The Arcoaire D5CMHA 30 000 multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 35,000 BTU/h at −8 °C, heats down to −30 °C and qualifies for a $4,200 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

2 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 215357141
35,000BTU/h at −8 °C
−30 °Cstill heating
2 → 4heads, on the same unit
2.4COP at −8 °C
$4,200LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

D5CMHAH30EAK

Outdoor unit

One compressor for the whole house. It supplies up to 4 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones
18,000BTU
2
24,000BTU
23
30,000BTU
Here34
36,000BTU
234
48,000BTU
2345
55,000BTU
2345

Arcoaire D5CMHA 30 000 · 2 zones

35,000 BTU/h
at −8 °C
$4,200
LogisVert

Up to 4 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 120 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling24.0
Scale 1 – 30
HSPF2 · seasonal heating10.7
Scale 1 – 15
EER2 · cooling in peak heat13.2
Scale 1 – 20
COP at −15 °C2.0
Scale 0 – 4
09 · LogisVert grant

A grant you can calculate, not guess.

35,000 BTU/h÷ 1,000 ×$120=$4,200

The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 215357141). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone2 wall units
On the wall1 outdoor unit2 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$4,200 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines under line covers, no work inside the walls.
05Dedicated circuit220 V. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

22,400Still 22,400 BTU/h at −30 °CAccording to NEEP, its certified maximum capacity at −30 °C (−22 °F) is 22,400 BTU/h, 75% of its nominal 30,000 BTU size.
10,000BTU/h at low speedMinimum certified capacity (NEEP): it slows down instead of stopping when the load drops.
$4,200LogisVert grantAmount for the owner of an existing home, according to Hydro-Québec’s list of October 19, 2026.
13 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)30,000 BTU · 2,5 tonsSheet
SEER2 (seasonal cooling efficiency)24.0AHRI
EER2 (instant cooling efficiency)13.2AHRI
HSPF2 (seasonal heating efficiency, region IV)10.7AHRI
Heating
Capacity at −8 °C35,000 BTU/h · COP 2.4Sheet
Capacity at −15 °C36,000 BTU/h · COP 2.0Sheet
Capacity at −30 °C (max.)22,400 BTU/h · COP 1.47Sheet
Heats down to−30 °CSheet
Zones and heads
Zones on this product2 Zones (Double Zone)Sheet
Maximum zones4 Zones (Quad Zone)Sheet
Possible indoor modelsD5FSHAH06XAK, D5FSHAH09XAK, D5FSHAH12XAK, D5FSHAH18XAKSheet
Installation
Electrical
Voltage220 VSheet
RefrigerantR-454BSheet
Wi-FiEn OptionSheet
Certifications and warranty
AHRI215357141AHRI
ENERGY STARYes · cold climate · ID 3722940Sheet
LogisVert grant (indicative)$4,200Sheet
Warranty (compressor · parts · labour)10 yrs · 10 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
14 · Official brochures

The manufacturer’s documentation, as PDF.

15 · Description

Everything we have written about this system.

Two large spaces, heated and cooled to their measure

Some homes do not need five heads, but two heads able to cover real floor area. The 2-Zone Heat Pump ARCOAIRE D5CMHA | 30,000 BTU - R454B is designed for that case: a large open ground floor and a finished basement, or the two full floors of a semi-detached house. Its 2.5-ton D5CMHAH30EAK condenser serves 2 zones and accepts up to 4 at most. It is built with the D5FSHAH06XAK, D5FSHAH09XAK, D5FSHAH12XAK and D5FSHAH18XAK wall-mounted heat pump heads, and its inverter compressor modulates its speed according to the demand of both zones.

Its ratings are 24.0 SEER2, 13.2 EER2 and 10.7 HSPF2. The system is ENERGY STAR certified with the cold-climate designation under ENERGY STAR ID 3722940. The certificate still lists its capacity at -30 °C, and the system qualifies for a $4,200 LogisVert grant.

An open area and a basement: two very different loads

An open-concept ground floor and a finished basement are almost opposites. Upstairs, large windows, cooking and the afternoon sun drive up the cooling load; in winter, the glass area and exterior doors make it the zone most exposed to the cold. Downstairs, the foundation walls keep a stable temperature: the basement stays cool in summer, but humid, and its cold floor calls for heat a good part of the year. A single wall unit placed upstairs does not go down the stairs; one head per level gives each its own set point.

The size of each head comes from the load calculation: floor area, ceiling height, windows, insulation of the foundation walls. A seventies house with an uninsulated basement does not have the needs of a recent build; we measure before we propose.

The D5FSHAH18XAK head for the large room

In an open area, the question is not only capacity but how far the air carries. The D5FSHAH18XAK head, the largest on the list, suits rooms where the air must travel the full length between the living room and the dining room. We preferably mount it on a short wall, so the airflow runs along the room rather than across it, making sure an island, a beam or a soffit does not cut it off. The adjustable louvers then direct the flow: upward in cooling, downward in heating.

The basement, the zone people overlook

A basement heated only by baseboards often remains the least pleasant room in the house. The basement head is mounted high on the wall, so warm air is pushed toward the floor in winter, and it offers an advantage in summer: the dehumidification mode removes the moisture that builds up against the foundation, without cooling a room that is already cool. For a family room, a home theatre or a basement office, that is often the difference between a room you avoid and a room you use.

January cold according to the certificate

A glassed-in open area is the first zone to cool down when the temperature plunges. This system's certificate lists 35,000 BTU/h at -8 °C and 36,000 BTU/h at -15 °C, two values above the nominal 30,000 BTU size. The two points are measured separately; we report each one as published.

  • COP of 2.40 at the -8 °C point (17 °F)
  • COP of 2.00 at the -15 °C point (5 °F)
  • Maximum capacity at -30 °C: 22,400 BTU/h, COP of 1.47
  • Heating certified down to -30 °C

These figures come from certificate AHRI 215357141, published by NEEP. For two zones, this reserve means a heat pump that keeps carrying most of the heating through the usual cold of the Montreal area. During extreme cold snaps, the existing baseboards serve as backup.

Two zones today, up to four tomorrow

The D5CMHAH30EAK accepts up to four heads. With two zones, two ports remain free for an upstairs bedroom, an office or a room added later. The addition remains possible provided the full set of heads stays within the combinations the manufacturer allows; that is why we choose the first two heads with what might follow in mind. We also place the condenser and plan the line route so that nothing has to be redone when a zone is added.

One condenser for two zones, rather than two units

You could get two zones with two independent wall-mounted heat pumps. Multi-zone has other strengths: only one unit to clear of snow outside, only one dedicated circuit at the panel, only one maintenance visit for the condenser. On the other hand, both heads work in the same mode at any given time, heating or cooling, and a condenser shutdown affects both zones at once. For a home whose two zones follow the same seasons, the balance clearly tips toward multi-zone.

The ratings, without jargon

The 24.0 SEER2 measures seasonal cooling efficiency; the 13.2 EER2 isolates the hottest days, when the glassed-in open area works hardest. The 10.7 HSPF2 sums up the heating season: the higher it is, the more heat each kilowatt-hour produces. COP is the snapshot of that efficiency at a given temperature: 2.40 at -8 °C means the heat pump delivers, as heat, more than double the electrical energy it consumes.

The $4,200 LogisVert grant

The system is listed in Hydro-Québec's LogisVert program, with $4,200 for the owner of an existing home, according to the list in effect on the installation date. We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.

Installation and maintenance

Our installation method

The in-home assessment sets the size of both heads, the condenser location and the line route. The job then follows a precise order.

  • The condenser is placed on a stand or a wall bracket, above the snow line, clear of snow and ice falling from the roof.
  • The ground-floor head is connected by a refrigerant line set under a finishing cover along the facade, with its communication cable and drain.
  • For the basement head, the lines usually pass through the rim joist; since the drain cannot always flow by gravity below ground level, a condensate pump is often needed.
  • The condenser is connected to a dedicated circuit, after checking the capacity of the electrical panel.
  • R-454B, a mildly flammable new-generation refrigerant, is handled according to its rules: leak test, vacuum, then commissioning of each zone and programming of the remotes with you.

Maintenance

Rinse the filters of both heads every two weeks in season; the ground-floor one clogs faster near a kitchen. Keep the condenser clear of snow and leaves, without covering it in winter. An annual HVAC maintenance visit cleans the coils and blower wheels, checks the drain and the condensate pump if there is one, and tightens the electrical connections. In winter, white vapour during defrost and a short pause in heating are normal. Our cleaning service takes over when you prefer to hand off the annual visit.

AirGreen, for the life of the installation

A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.

Request your free estimate for the 2-Zone Heat Pump ARCOAIRE D5CMHA | 30,000 BTU - R454B. We assess your two spaces, choose the size of each head with future zones in mind and confirm your grant eligibility before signing.

Warranty: 10 years on the compressor, 10 years on parts and 6 years on labor.

16 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 35,000 BTU/h at −8 °C, 36,000 at −15 °C and 22,400 at −30 °C.

How many heads can I connect?

Up to 4 on this outdoor unit. This product is configured for 2 heads.

How much is the LogisVert grant?

$4,200. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 3722940.

Down to what temperature does it heat?

Down to −30 °C. At −30 °C, it still delivers 22,400 BTU/h with a COP of 1.47.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $4,200Indicative amount
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.