4-Zone Heat Pump ARCOAIRE D5CMHA | 30,000 BTU - R454B
The Arcoaire D5CMHA 30 000 multi-zone heat pump heats and cools 4 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 35,000 BTU/h at −8 °C, heats down to −30 °C and qualifies for a $4,200 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.
4 rooms, one outdoor unit.
Figures come from the manufacturer’s data and the AHRI certification.
The parts that make a multi-zone system.
Tap a part to learn more.
Outdoor unit
One compressor for the whole house. It supplies up to 4 heads.
Base pan heater
A heater keeps the outdoor unit’s base pan free of ice below 1 °C and during defrost (NEEP).
Refrigerant lines
One pair of lines per head.
Indoor heads
One head per room, each with its own remote and temperature. The combination is chosen in the “Zones” menu.
Control
Each zone is set separately.
Turn rooms on and off. Watch the power being shared.
One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.
Tell us your rooms. We tell you if this size is enough.
Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.
The whole series at a glance: find the box that fits you.
Each box is a product: the outdoor unit’s size, and the number of heads.
At −15 °C, it still delivers 120 % of its rated capacity.
Tap a temperature: capacity, efficiency and the cost of one hour of heating.
At every temperature, cheaper than baseboards.
Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.
The official ratings, on the same scales as before.
SEER2, HSPF2 and EER2 come from the AHRI certification.
A grant you can calculate, not guess.
The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).
One multi-zone or several wall units? Both sides, honestly.
We compare both options on your floor plan during the estimate.
What to know before installing a multi-zone system.
Dimensions, wiring and lines, drawn. Then our six steps.
What is particular about this machine.
Only facts published by ENERGY STAR, NEEP or the manufacturer.
Every number, and where it comes from.
Each line carries its source; a line with no published value is not shown.
The manufacturer’s documentation, as PDF.
Everything we have written about this system.
Four set points for four modestly sized rooms
A living room on the ground floor, three bedrooms upstairs: that is the layout of many two-storey and semi-detached houses, and it is exactly the case the 4-Zone Heat Pump ARCOAIRE D5CMHA | 30,000 BTU - R454B targets. Its 2.5-ton D5CMHAH30EAK condenser serves 4 zones (up to 4 at most): one head per room, each with its own remote, on a single outdoor unit. The heads are chosen from the D5FSHAH06XAK, D5FSHAH09XAK, D5FSHAH12XAK and D5FSHAH18XAK wall-mounted heat pump models, and the inverter compressor distributes its capacity according to the zones that are calling.
Its ratings are 24.0 SEER2, 13.2 EER2 and 10.7 HSPF2. The system is ENERGY STAR certified with the cold-climate designation under ENERGY STAR ID 3722940. The certificate still lists its capacity at -30 °C, and our product sheet shows an indicative LogisVert amount of $4,200.
Who this four-head system is for
It suits homes with many rooms of reasonable size: a two-storey house with a living room and three bedrooms, a semi-detached house with an open ground floor, a primary bedroom, a child's bedroom and an office, or a large 5 ½ condo where each closed room deserves its own set point. The common denominator: four zones, but no very large room.
If two of your four zones are large spaces, for example a glassed-in open area and an entire basement, a larger condenser or a different split will be a better fit. The age of the windows, the attic insulation and the orientation of the bedrooms also count; the room-by-room on-site assessment sorts it out.
2.5 tons for four zones: the art of sharing
Four heads connected to a 2.5-ton condenser share its capacity. This sharing works because the four rooms rarely need the maximum at the same time: the living room works by day, the bedrooms in the evening, the office during working hours. The condenser meters the refrigerant sent to each head according to its demand, and the compressor speed follows the total.
The choice of heads follows from this. In this size, each room gets the smallest head that covers it properly: often the D5FSHAH06XAK or the D5FSHAH09XAK for the bedrooms, a larger size for the living room. The total must stay within the combinations the manufacturer allows. Oversizing each head out of caution adds no comfort; it makes the small rooms cycle and reduces dehumidification.
A complete plan from the start
With four heads, the D5CMHAH30EAK uses all its ports: no fifth zone can be added. That means thinking about the whole house during the visit, including the rooms you plan to convert. A guest room that will become an office, a child's room that will be occupied in a year: better to count them now than to find out later that a port is missing.
Managing four zones day to day
Each head has its own remote, with set point, fan speed and timer. A guest room can stay at a reduced temperature all week; the office can warm up half an hour before the workday starts. Avoid, however, turning a room off completely in the middle of winter: a room that gets too cold chills the neighbouring walls and forces the other heads to compensate. A useful reminder for multi-zone: all four heads work in the same mode at any given time. In spring, when the sunny living room would like some cooling while a north-facing bedroom still wants heat, choose the mode of the season and adjust the set points.
The certificate, point by point
The certificate lists 35,000 BTU/h at -8 °C and 36,000 BTU/h at -15 °C. The two points are measured separately; we report each one as published.
- COP of 2.40 at the -8 °C point (17 °F)
- COP of 2.00 at the -15 °C point (5 °F)
- Maximum capacity at -30 °C: 22,400 BTU/h, COP of 1.47
- Heating certified down to -30 °C
For four modestly sized zones, these values cover the usual cold of the Montreal area, even when every room is calling at once. As temperatures approach -30 °C, the published capacity drops, and the existing baseboards serve as backup, especially in corner bedrooms. These figures come from certificate AHRI 215357141, published by NEEP.
Summer: four rooms on the same compressor
In July, the upstairs bedrooms heat up under the roof while the living room gets the afternoon sun. The compressor speeds up when several zones call, then slows down and holds the set points at low speed. It is during these long cycles that each head's coil removes moisture; the dehumidification mode takes over on humid evenings. R-454B, a new-generation refrigerant with a global warming potential markedly lower than the fluids it replaces, circulates in all four circuits.
What the ratings mean
The 24.0 SEER2 measures cooling efficiency over the whole season, the 13.2 EER2 in the hottest condition. The 10.7 HSPF2 does the same exercise for heating. The higher these figures, the less comfort costs in electricity. COP reads as a ratio: 2.00 at -15 °C means two units of heat for one unit of electricity, where a baseboard gives only one.
Indicative LogisVert amount: $4,200
Our product sheet shows an indicative LogisVert amount of $4,200 for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.
Installing four heads cleanly
Four line sets, four drains: the planning
Four heads means four refrigerant line sets, four communication cables and four drains to route cleanly. During the in-home assessment, we draw the route: the lines from the upstairs bedrooms often come down the same exterior wall, grouped under a finishing cover, so that only one visible run remains on the facade. The drains flow by gravity when the exterior wall allows it; otherwise, a discreet condensate pump takes over. The condenser goes on a stand or a wall bracket, above the snow line and out of the path of snow falling from the roof, and it is connected to a dedicated circuit after checking the electrical panel. Commissioning includes the leak test, the vacuum, a check of each of the four zones and programming the remotes with you.
Maintenance
Four heads, four filters to rinse every two weeks in season; a few minutes per room. Keep the condenser clear of snow and leaves, and do not cover it in winter. An annual HVAC maintenance visit cleans the coils and blower wheels, checks each drain and tightens the electrical connections. In winter, white vapour during defrost and a short pause in heating are normal. Our cleaning service takes over when you prefer to hand off the annual visit.
AirGreen, for the life of the installation
A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.
Request your free estimate for the 4-Zone Heat Pump ARCOAIRE D5CMHA | 30,000 BTU - R454B. We assess your four rooms, choose the best-fitting combination of heads and confirm your grant eligibility before signing.
Warranty: 10 years on the compressor, 10 years on parts and 6 years on labor.
What people ask us about multi-zone systems.
Can I heat one room and cool another at the same time?
No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.
What happens when every room calls for heat?
They share the outdoor unit’s capacity: 35,000 BTU/h at −8 °C, 36,000 at −15 °C and 22,400 at −30 °C.
How many heads can I connect?
Up to 4 on this outdoor unit. This product is configured for 4 heads.
How much is the LogisVert grant?
$4,200. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.
Is it ENERGY STAR certified?
Yes, cold climate, ID 3722940.
Down to what temperature does it heat?
Down to −30 °C. At −30 °C, it still delivers 22,400 BTU/h with a COP of 1.47.
Why a multi-zone instead of several wall units?
One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.
What does the warranty cover?
Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.
A multi-zone system is planned room by room. At your home.
We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.